2CSR273001R1255 ABB DS203 M AC-B25/0.03 RCBO 3P 25 A 30 mA 10 kA

2CSR273001R1255 ABB DS203 M AC-B25/0.03 RCBO 3P 25 A 30 mA 10 kA

ABB DS203 M AC-B25/0.03 is a 25 A 3-pole Type AC 30 mA RCBO with B-curve overcurrent protection and 10 kA short-circuit breaking capacity for commercial and industrial three-phase electrical circuits.

SKU: 2CSR273001R1255Alt SKU: DS203MACB250.03MPN: 2CSR273001R1255
Price
List Price £318.39 ex VAT
Your Price (ex VAT) Save 35%
£206.95 35% OFF
You save £111.44 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £206.95
Trade pricing is personalised to your account

Manufacturer Lead Time

£206.95

Why Choose the ABB DS203 M AC-B25/0.03 RCBO?

The ABB DS203 M AC-B25/0.03, order code 2CSR273001R1255, is a high-performance 3-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase electrical circuits against overloads, short circuits and sinusoidal alternating earth fault currents. Part of the ABB DS200 / DSH200 RCBO product group, it combines residual-current and overcurrent protection in a factory-assembled device for commercial and industrial electrical installations.

This DS200 M series RCBO uses Type AC residual-current protection together with a B tripping characteristic. It provides protection against indirect contact and, with its 30 mA rated residual operating current, additional protection against direct contact. The B-curve characteristic is suited to circuits with relatively low starting and inrush currents.

With a rated current of 25 A, 30 mA residual-current sensitivity and 10 kA rated short-circuit breaking capacity, the DS203 M AC-B25/0.03 provides robust combined protection for three-pole circuits. Its DIN rail construction makes it suitable for professional distribution boards and control panels where dependable three-phase residual-current and overcurrent protection is required.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one device.
  • 25 A rated current with B-curve overcurrent tripping characteristic.
  • 30 mA residual current sensitivity provides additional protection against direct contact.
  • Type AC protection for sinusoidal alternating residual currents.
  • 3-pole configuration for three-phase electrical circuits.
  • 10 kA rated short-circuit breaking capacity for demanding commercial and industrial applications.
  • Factory-assembled RCBO construction combines residual-current and overcurrent protection in a single device.
  • DIN rail mounting enables straightforward integration into modular three-phase distribution systems.

Key Features

  • ABB DS200 M RCBO series.
  • 25 A rated current.
  • B tripping characteristic.
  • 30 mA rated residual current (IΔn).
  • Type AC residual-current protection.
  • 3-pole configuration.
  • 3 protected poles.
  • 10 kA rated short-circuit breaking capacity (Icn).
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal alternating earth fault currents.
  • Protection against indirect contact and additional protection against direct contact.
  • B-curve operation suited to circuits with relatively low starting or inrush currents.
  • Designed for commercial and industrial electrical applications.
  • DIN rail mounting for integration into modular distribution systems.

Reliable 10 kA Three-Phase Circuit Protection

An RCBO combines residual-current protection with overload and short-circuit protection within a single device. The ABB DS203 M AC-B25/0.03 protects three-pole circuits against excessive current while also detecting sinusoidal alternating earth leakage currents, providing coordinated protection for commercial and industrial three-phase electrical distribution systems.

The DS203 M AC-B25/0.03 combines its 25 A B-curve overcurrent characteristic with 30 mA Type AC residual-current protection and a 10 kA rated short-circuit breaking capacity. This combination makes it suitable for three-phase circuits with comparatively low inrush currents where combined overload, short-circuit and Type AC earth fault protection is required.

Typical Applications

  • Commercial three-phase electrical distribution systems.
  • Industrial distribution boards and control panels.
  • Circuits requiring combined 25 A overcurrent and 30 mA residual-current protection.
  • Three-phase resistive and low-inrush loads suited to a B-curve characteristic.
  • Three-pole circuits requiring Type AC residual-current protection.
  • Installations requiring a 10 kA rated short-circuit breaking capacity.

Technical Specifications

Product group DS200 / DSH200 RCBO
Series DS200 M
ABB order code 2CSR273001R1255
EAN 8012542933700
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3
Protected poles 3
Rated current 25 A
Tripping characteristic B curve
Rated residual current (IΔn) 30 mA
Residual current type Type AC
Rated short-circuit breaking capacity (Icn) 10 kA
Standards IEC/EN 61009-1; IEC/EN 61009-2-1
Terminal type Screw terminals
Application Commercial and industrial electrical installations
Mounting DIN rail
Weight approx. 0.61 kg

Frequently Asked Questions

What is the ABB DS203 M AC-B25/0.03 used for?

The ABB DS203 M AC-B25/0.03 is a 3-pole RCBO used to protect three-phase electrical circuits against overloads, short circuits and sinusoidal alternating earth fault currents in commercial and industrial installations.

What is the current rating of the DS203 M AC-B25/0.03?

The RCBO has a rated current of 25 A and uses a B-curve tripping characteristic.

What residual current sensitivity does this RCBO have?

The DS203 M AC-B25/0.03 has a rated residual operating current of 30 mA and uses Type AC residual-current protection.

What is the breaking capacity of the ABB DS203 M AC-B25/0.03?

The DS203 M AC-B25/0.03 has a rated short-circuit breaking capacity (Icn) of 10 kA, providing robust short-circuit protection for suitable commercial and industrial three-phase installations.

What does Type AC mean on the ABB DS203 M AC-B25/0.03?

Type AC means the RCBO is designed to detect sinusoidal alternating residual currents, providing residual-current protection for applications where this type of earth leakage current is expected.