2CSR273001R1254 ABB DS203 M AC-C25/0.03 RCBO 3P 25 A 30 mA 10 kA

2CSR273001R1254 ABB DS203 M AC-C25/0.03 RCBO 3P 25 A 30 mA 10 kA

ABB DS203 M AC-C25/0.03 is a 25 A 3-pole Type AC 30 mA RCBO with C-curve overcurrent protection and 10 kA short-circuit breaking capacity for commercial and industrial three-phase electrical circuits.

SKU: 2CSR273001R1254Alt SKU: DS203MACC250.03MPN: 2CSR273001R1254
Price
List Price £328.52 ex VAT
Your Price (ex VAT) Save 35%
£213.54 35% OFF
You save £114.98 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £213.54
Trade pricing is personalised to your account

Manufacturer Lead Time

£213.54

Why Choose the ABB DS203 M AC-C25/0.03 RCBO?

The ABB DS203 M AC-C25/0.03, order code 2CSR273001R1254, is a high-performance 3-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase electrical circuits against overloads, short circuits and sinusoidal alternating earth fault currents. Part of the ABB DS200 / DSH200 RCBO product group, it combines residual-current and overcurrent protection in a factory-assembled device for commercial and industrial electrical installations.

This DS200 M series RCBO uses Type AC residual-current protection together with a C tripping characteristic. It provides protection against indirect contact and, with its 30 mA rated residual operating current, additional protection against direct contact. The C-curve characteristic provides magnetic tripping between approximately five and ten times rated current, making it suitable for circuits with moderate starting or inrush currents.

With a rated current of 25 A, 400 V AC rated voltage, 30 mA residual-current sensitivity and 10 kA short-circuit breaking capacity, the DS203 M AC-C25/0.03 provides robust combined protection for three-pole circuits. Its DIN rail construction and integration with ABB's System pro M compact range make it suitable for professional distribution boards and control panels.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one device.
  • 25 A rated current with C-curve overcurrent tripping characteristic.
  • 30 mA residual current sensitivity provides additional protection against direct contact.
  • Type AC protection for sinusoidal alternating residual currents.
  • 3-pole configuration with three protected poles for three-phase circuits.
  • 10 kA short-circuit breaking capacity for demanding commercial and industrial applications.
  • Factory-assembled RCBO construction combines residual-current and overcurrent protection in a single device.
  • DIN rail mounting enables straightforward integration into modular electrical distribution systems.

Key Features

  • ABB DS200 M RCBO series.
  • 25 A rated current.
  • C tripping characteristic.
  • 30 mA rated residual current (IΔn).
  • Type AC residual-current protection.
  • 3-pole configuration.
  • 3 protected poles.
  • 400 V AC rated voltage.
  • 10 kA short-circuit breaking capacity.
  • 15 kA rated ultimate short-circuit breaking capacity (Icu) at 400 V AC.
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal alternating earth fault currents.
  • Protection against indirect contact and additional protection against direct contact.
  • Designed for commercial and industrial three-phase electrical applications.

Reliable 10 kA Three-Phase Circuit Protection

An RCBO combines residual-current protection with overload and short-circuit protection within a single device. The ABB DS203 M AC-C25/0.03 protects all three poles of the connected circuit against excessive current while also detecting sinusoidal alternating earth leakage currents, providing coordinated protection for commercial and industrial three-phase electrical distribution systems.

The DS203 M AC-C25/0.03 combines its 25 A C-curve overcurrent characteristic with 30 mA Type AC residual-current protection and a 10 kA short-circuit breaking capacity. This combination makes it suitable for three-phase circuits with moderate inrush currents where combined overload, short-circuit and Type AC earth fault protection is required.

Typical Applications

  • Commercial three-phase electrical distribution systems.
  • Industrial distribution boards and control panels.
  • Circuits requiring combined 25 A overcurrent and 30 mA residual-current protection.
  • Three-phase resistive and inductive loads suited to a C-curve characteristic.
  • Three-pole circuits requiring Type AC residual-current protection.
  • Installations requiring a 10 kA short-circuit breaking capacity.

Technical Specifications

Product group DS200 / DSH200 RCBO
Series DS200 M
ABB order code 2CSR273001R1254
EAN 8012542853008
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3
Protected poles 3
Rated current 25 A
Tripping characteristic C curve
Rated residual current (IΔn) 30 mA
Residual current type Type AC
Rated voltage 400 V AC
Short-circuit breaking capacity 10 kA
Rated ultimate short-circuit breaking capacity (Icu) 15 kA at 400 V AC
Standard IEC/EN 60947-2
Application Commercial and industrial electrical installations
Mounting DIN rail
Weight approx. 0.61 kg

Frequently Asked Questions

What is the ABB DS203 M AC-C25/0.03 used for?

The ABB DS203 M AC-C25/0.03 is a 3-pole RCBO used to protect three-phase electrical circuits against overloads, short circuits and sinusoidal alternating earth fault currents in commercial and industrial installations.

What is the current rating of the DS203 M AC-C25/0.03?

The RCBO has a rated current of 25 A and uses a C-curve tripping characteristic.

What residual current sensitivity does this RCBO have?

The DS203 M AC-C25/0.03 has a rated residual operating current of 30 mA and uses Type AC residual-current protection.

What is the breaking capacity of the ABB DS203 M AC-C25/0.03?

The DS203 M AC-C25/0.03 has a 10 kA short-circuit breaking capacity and a rated ultimate short-circuit breaking capacity (Icu) of 15 kA at 400 V AC.

What does Type AC mean on the ABB DS203 M AC-C25/0.03?

Type AC means the RCBO is designed to detect sinusoidal alternating residual currents, providing residual-current protection for applications where this type of earth leakage current is expected.

Trusted ABB Circuit Protection

ABB DS200 M RCBOs combine residual-current and overcurrent protection in factory-assembled devices designed for reliable electrical distribution, with the DS203 M range providing three-pole protection for commercial and industrial three-phase applications.