2CSR272101R1634 ABB DS202 M A-C63/0.03 RCBO 2P 63 A 30 mA 10 kA

2CSR272101R1634 ABB DS202 M A-C63/0.03 RCBO 2P 63 A 30 mA 10 kA

ABB DS202 M A-C63/0.03 is a 63 A 2-pole Type A 30 mA RCBO with C-curve overcurrent protection and 10 kA short-circuit breaking capacity for commercial and industrial electrical circuits.

SKU: 2CSR272101R1634Alt SKU: DS202MAC630.03MPN: 2CSR272101R1634
Price
List Price £362.71 ex VAT
Your Price (ex VAT) Save 35%
£235.76 35% OFF
You save £126.95 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £235.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£235.76

Why Choose the ABB DS202 M A-C63/0.03 RCBO?

The ABB DS202 M A-C63/0.03, order code 2CSR272101R1634, is a high-performance 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect electrical circuits against overloads, short circuits and earth fault currents. Part of the ABB DS200 / DSH200 RCBO product group, it combines residual-current and overcurrent protection in a factory-assembled device for commercial and industrial electrical installations.

This DS200 M series RCBO uses Type A residual-current protection together with a C tripping characteristic. Type A protection detects both sinusoidal alternating and pulsating DC residual currents, making it suitable for circuits supplying modern electrical and electronic equipment. Its 30 mA rated residual operating current provides protection against indirect contact and additional protection against direct contact.

With a rated current of 63 A, 230 V AC rated operational voltage, 30 mA residual-current sensitivity and 10 kA rated short-circuit breaking capacity, the DS202 M A-C63/0.03 provides robust combined protection for demanding two-pole circuits. This 63 A version is also provided with additional terminals for remote tripping, extending its suitability for professional distribution and control applications.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one device.
  • 63 A rated current with C-curve overcurrent tripping characteristic.
  • 30 mA residual current sensitivity provides additional protection against direct contact.
  • Type A protection detects sinusoidal AC and pulsating DC residual currents.
  • 2-pole configuration for two-pole electrical circuits.
  • 10 kA rated short-circuit breaking capacity for demanding commercial and industrial applications.
  • Additional terminals for remote tripping on this 63 A version.
  • Factory-assembled RCBO construction combines residual-current and overcurrent protection in a single device.

Key Features

  • ABB DS200 M RCBO series.
  • 63 A rated current.
  • C tripping characteristic.
  • 30 mA rated residual current (IΔn).
  • Type A residual-current protection.
  • Detection of sinusoidal alternating and pulsating DC residual currents.
  • 2-pole configuration.
  • 230 V AC rated operational voltage.
  • 10 kA rated short-circuit breaking capacity (Icn).
  • 15 kA rated ultimate short-circuit breaking capacity (Icu) at 400 V AC.
  • Additional terminals for remote tripping.
  • Protection against overload and short-circuit currents.
  • Protection against indirect contact and additional protection against direct contact.
  • Designed for commercial and industrial electrical applications.

High-Performance Type A Circuit Protection

An RCBO combines residual-current protection with overload and short-circuit protection within a single device. The ABB DS202 M A-C63/0.03 provides Type A residual-current detection, allowing it to respond to sinusoidal alternating as well as pulsating DC earth fault currents. This makes Type A protection particularly relevant to modern circuits containing electronic equipment capable of producing non-sinusoidal residual currents.

The DS202 M A-C63/0.03 combines its 63 A C-curve overcurrent characteristic with 30 mA residual-current protection and a 10 kA rated short-circuit breaking capacity. Its additional remote-tripping terminals further enhance integration into professional commercial and industrial distribution systems where remote operation or control functionality is required.

Typical Applications

  • Commercial electrical distribution systems.
  • Industrial distribution boards and control panels.
  • Circuits requiring combined 63 A overcurrent and 30 mA residual-current protection.
  • Circuits supplying equipment capable of producing pulsating DC residual currents.
  • Resistive and inductive loads suited to a C-curve characteristic.
  • Two-pole circuits requiring Type A residual-current protection.
  • Installations requiring a 10 kA rated short-circuit breaking capacity.
  • Applications where additional terminals for remote tripping are beneficial.

Technical Specifications

Product group DS200 / DSH200 RCBO
Series DS200 M
ABB order code 2CSR272101R1634
EAN 8012542849407
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 63 A
Tripping characteristic C curve
Rated residual current (IΔn) 30 mA
Residual current type Type A
Operating characteristic Instantaneous
Rated voltage 230 V AC
Rated operational voltage 230 V AC
Rated frequency 50–60 Hz
Rated short-circuit breaking capacity (Icn) 10 kA
Rated ultimate short-circuit breaking capacity (Icu) 15 kA at 400 V AC
Standards IEC/EN 60947-2; IEC/EN 61009-1
Additional provision Additional terminals for remote tripping
Application Commercial and industrial electrical installations
Mounting DIN rail
Width 70 mm
Height 93 mm
Depth 69 mm
Weight approx. 0.44 kg

Frequently Asked Questions

What is the ABB DS202 M A-C63/0.03 used for?

The ABB DS202 M A-C63/0.03 is a 2-pole Type A RCBO used to protect commercial and industrial electrical circuits against overloads, short circuits and sinusoidal AC or pulsating DC earth fault currents.

What is the current rating of the DS202 M A-C63/0.03?

The RCBO has a rated current of 63 A and uses a C-curve tripping characteristic.

What residual current sensitivity does this RCBO have?

The DS202 M A-C63/0.03 has a rated residual operating current of 30 mA, providing protection against indirect contact and additional protection against direct contact.

What is the breaking capacity of the ABB DS202 M A-C63/0.03?

The DS202 M A-C63/0.03 has a rated short-circuit breaking capacity (Icn) of 10 kA and a rated ultimate short-circuit breaking capacity (Icu) of 15 kA at 400 V AC.

What does Type A mean on the ABB DS202 M A-C63/0.03?

Type A means the RCBO is designed to detect both sinusoidal alternating and pulsating DC residual currents, making it suitable for circuits where electronic equipment may produce pulsating DC earth leakage components.

Trusted ABB Circuit Protection

ABB DS200 M RCBOs combine residual-current and overcurrent protection in factory-assembled devices designed for reliable commercial and industrial electrical distribution, with high short-circuit breaking capacity and Type A options for circuits requiring detection of both sinusoidal AC and pulsating DC residual currents.