2CSR272101R1505 ABB DS202MAB500.03 DS202 M A-B50/0.03 50 A 30 mA RCBO

2CSR272101R1505 ABB DS202MAB500.03 DS202 M A-B50/0.03 50 A 30 mA RCBO

ABB DS202MAB500.03 is a 2-pole 50 A Type B Type A RCBO with 30 mA residual-current sensitivity and 10 kA short-circuit capacity for commercial and industrial circuit protection.

SKU: 2CSR272101R1505Alt SKU: DS202MAB500.03MPN: 2CSR272101R1505
Price
List Price £351.75 ex VAT
Your Price (ex VAT) Save 35%
£228.64 35% OFF
You save £123.11 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £228.64
Trade pricing is personalised to your account

Manufacturer Lead Time

£228.64

Why Choose the ABB DS202MAB500.03 RCBO?

The ABB DS202MAB500.03 is a high-performance 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and earth fault currents. Part of the proven ABB DS200 / DS202 M series, it combines residual-current and overcurrent protection within a factory-assembled DIN-rail device for demanding commercial and industrial electrical installations.

With a rated current of 50 A, 30 mA residual-current sensitivity and Type B tripping characteristic, the DS202 M A-B50/0.03 provides dependable protection for final circuits requiring sensitive overcurrent operation. Its Type A residual-current detection responds to sinusoidal alternating and pulsating DC earth fault currents, making it suitable for modern circuits containing electronic equipment.

The DS202MAB500.03 provides a rated short-circuit capacity of 10 kA and is intended for commercial and industrial applications. ABB supplies this model under order code 2CSR272101R1505, with a test pushbutton for functional verification and indication features that assist inspection and fault identification.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one device.
  • 50 A rated current for higher-current final circuits.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type B tripping characteristic for responsive overcurrent protection.
  • Type A residual-current detection for sinusoidal AC and pulsating DC earth fault currents.
  • 10 kA rated short-circuit capacity for demanding installations.
  • Integrated test pushbutton enables routine verification of residual-current operation.
  • Factory-combined ABB DS200 construction simplifies installation and wiring.

Key Features

  • ABB DS202 M A RCBO from the DS200 series.
  • 2-pole configuration.
  • 50 A rated current.
  • 30 mA rated residual operating current.
  • B characteristic overcurrent release.
  • Type A residual-current protection.
  • 10 kA nominal short-circuit breaking capacity.
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal alternating and direct pulsating earth fault currents.
  • DIN-rail format for electrical distribution equipment.
  • Test pushbutton for checking correct residual-current functionality.

Reliable Type A Circuit and Residual-Current Protection

RCBOs combine overcurrent and residual-current protection within a single protective device. The ABB DS202 M A-B50/0.03 protects connected circuits against overload and short-circuit currents while also detecting sinusoidal alternating and pulsating DC earth fault currents that can occur in modern electrical installations.

The ABB DS200 range is designed for demanding commercial and industrial applications. Its factory-combined construction helps reduce installation time, while features including the test pushbutton, earth fault indication and contact-position indication support efficient testing, maintenance and fault identification.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial electrical installations.
  • Higher-current final circuit protection.
  • Lighting and general power circuits.
  • Circuits supplying equipment containing electronic components.
  • Electrical control and distribution panels.
  • Circuits requiring combined 30 mA Type A residual-current and overcurrent protection.

Technical Specifications

Series DS200 / DS202 M
SKU DS202MAB500.03
ABB order code 2CSR272101R1505
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 50 A
Tripping characteristic B
Residual-current type A
Rated residual current 30 mA
Rated short-circuit capacity (Icn) 10 kA
Standards IEC/EN 61009-1; IEC/EN 61009-2-1
Weight 0.44 kg
Mounting DIN rail

Frequently Asked Questions

What is the ABB DS202MAB500.03 used for?

The ABB DS202MAB500.03 provides combined protection against overloads, short circuits and Type A residual currents in commercial and industrial electrical installations.

What is the rated current of the DS202 M A-B50/0.03?

The RCBO has a rated current of 50 A and uses a Type B tripping characteristic.

What residual-current protection does this RCBO provide?

The DS202 M A-B50/0.03 has a rated residual operating current of 30 mA and uses Type A detection for sinusoidal alternating and pulsating DC residual currents.

What is the short-circuit capacity of the ABB DS202MAB500.03?

The device has a rated nominal short-circuit breaking capacity of 10 kA, making it suitable for demanding commercial and industrial circuit-protection applications.

What is the ABB order code for the DS202 M A-B50/0.03?

The ABB order code is 2CSR272101R1505.

Trusted ABB Circuit Protection

ABB DS200 series RCBOs provide integrated residual-current and overcurrent protection for commercial and industrial electrical systems, combining dependable circuit protection with practical installation, testing and fault-indication features.