2CSR272001R1634 ABB DS202 M AC-C63/0.03 RCBO 2P 63 A 30 mA 10 kA

2CSR272001R1634 ABB DS202 M AC-C63/0.03 RCBO 2P 63 A 30 mA 10 kA

ABB DS202 M AC-C63/0.03 is a 63 A 2-pole Type AC 30 mA RCBO with C-curve overcurrent protection and 10 kA short-circuit breaking capacity for commercial and industrial electrical circuits.

SKU: 2CSR272001R1634Alt SKU: DS202MACC630.03MPN: 2CSR272001R1634
Price
List Price £319.46 ex VAT
Your Price (ex VAT) Save 35%
£207.65 35% OFF
You save £111.81 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £207.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£207.65

Why Choose the ABB DS202 M AC-C63/0.03 RCBO?

The ABB DS202 M AC-C63/0.03, order code 2CSR272001R1634, is a 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect electrical circuits against overloads, short circuits and sinusoidal alternating earth fault currents. Part of the ABB DS200 / DSH200 RCBO product group, it combines residual-current and overcurrent protection in a single device for commercial and industrial electrical installations.

This DS200 M series RCBO uses Type AC residual-current protection together with a C tripping characteristic. It provides protection against indirect contact and, with its 30 mA rated residual operating current, additional protection against direct contact. The C-curve characteristic is suitable for circuits with moderate starting or inrush currents commonly encountered in commercial and industrial applications.

With a rated current of 63 A, 230 V AC rated operational voltage, 30 mA residual-current sensitivity and 10 kA rated short-circuit breaking capacity, the DS202 M AC-C63/0.03 provides robust combined protection for two-pole circuits. Its DIN rail construction makes it suitable for professional distribution boards and control panels requiring dependable high-current circuit protection.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one device.
  • 63 A rated current with C-curve overcurrent tripping characteristic.
  • 30 mA residual current sensitivity provides additional protection against direct contact.
  • Type AC protection for sinusoidal alternating residual currents.
  • 2-pole configuration with two protected poles.
  • 10 kA rated short-circuit breaking capacity for demanding commercial and industrial applications.
  • Factory-assembled RCBO construction combines residual-current and overcurrent protection in a single device.
  • DIN rail mounting enables straightforward integration into modular electrical distribution systems.

Key Features

  • ABB DS200 M RCBO series.
  • 63 A rated current.
  • C tripping characteristic.
  • 30 mA rated residual current (IΔn).
  • Type AC residual-current protection.
  • 2-pole configuration.
  • 2 protected poles.
  • 230 V AC rated operational voltage.
  • 10 kA rated short-circuit breaking capacity (Icn).
  • 15 kA ultimate short-circuit breaking capacity (Icu) at 400 V AC.
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal alternating earth fault currents.
  • Protection against indirect contact and additional protection against direct contact.
  • DIN rail mounting for integration into modular distribution systems.

Reliable 10 kA Combined Circuit Protection

An RCBO combines residual-current protection with overload and short-circuit protection within a single device. The ABB DS202 M AC-C63/0.03 protects connected circuits against excessive current while also detecting sinusoidal alternating earth leakage currents, providing coordinated electrical protection for commercial and industrial distribution systems.

The DS200 M series is designed for demanding applications, and the DS202 M AC-C63/0.03 provides a 10 kA rated short-circuit breaking capacity. Its 30 mA Type AC protection provides additional protection against direct contact where Type AC residual-current detection is appropriate, while the 63 A C-curve characteristic makes it suitable for higher-current circuits with moderate inrush requirements.

Typical Applications

  • Commercial electrical distribution systems.
  • Industrial distribution boards and control panels.
  • Circuits requiring combined 63 A overcurrent and 30 mA residual-current protection.
  • Resistive and inductive loads suited to a C-curve characteristic.
  • Two-pole circuits requiring Type AC residual-current protection.
  • Installations requiring a 10 kA rated short-circuit breaking capacity.

Technical Specifications

Product group DS200 / DSH200 RCBO
Series DS200 M
ABB order code 2CSR272001R1634
EAN 8012542852407
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Protected poles 2
Rated current 63 A
Tripping characteristic C curve
Rated residual current (IΔn) 30 mA
Residual current type Type AC
Rated operational voltage 230 V AC
Rated short-circuit breaking capacity (Icn) 10 kA
Rated ultimate short-circuit breaking capacity (Icu) 15 kA at 400 V AC
Standards IEC/EN 61009-1; IEC/EN 61009-2-1
Application Commercial and industrial electrical installations
Mounting DIN rail
Weight approx. 0.44 kg

Frequently Asked Questions

What is the ABB DS202 M AC-C63/0.03 used for?

The ABB DS202 M AC-C63/0.03 is a 2-pole RCBO used to protect electrical circuits against overloads, short circuits and sinusoidal alternating earth fault currents in commercial and industrial installations.

What is the current rating of the DS202 M AC-C63/0.03?

The RCBO has a rated current of 63 A and uses a C-curve tripping characteristic.

What residual current sensitivity does this RCBO have?

The DS202 M AC-C63/0.03 has a rated residual operating current of 30 mA and uses Type AC residual-current protection.

What is the breaking capacity of the ABB DS202 M AC-C63/0.03?

The DS202 M AC-C63/0.03 has a rated short-circuit breaking capacity (Icn) of 10 kA.

What does Type AC mean on the ABB DS202 M AC-C63/0.03?

Type AC means the RCBO is designed to detect sinusoidal alternating residual currents, providing residual-current protection for applications where this type of earth leakage current is expected.

Trusted ABB Circuit Protection

ABB DS200 M RCBOs combine residual-current and overcurrent protection in factory-assembled devices designed for reliable commercial and industrial electrical distribution, with high short-circuit breaking capacity and straightforward integration into modular installations.