2CSR272001R1255 ABB DS202MACB250.03 DS202 M AC-B25/0.03 2P Type AC RCBO 25A 30mA 10kA

2CSR272001R1255 ABB DS202MACB250.03 DS202 M AC-B25/0.03 2P Type AC RCBO 25A 30mA 10kA

ABB DS202MACB250.03 is a 2-pole Type AC RCBO with 25 A rated current, B tripping characteristic, 30 mA residual-current sensitivity and 10 kA short-circuit breaking capacity.

SKU: 2CSR272001R1255Alt SKU: DS202MACB250.03MPN: 2CSR272001R1255
Price
List Price £235.88 ex VAT
Your Price (ex VAT) Save 35%
£153.32 35% OFF
You save £82.56 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £153.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£153.32

Why Choose the ABB DS202MACB250.03 RCBO?

The ABB DS202MACB250.03 is a 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to combine overload, short-circuit and residual earth-fault protection within a single modular device. Part of ABB's DS200 / DSH200 RCBO portfolio, it provides coordinated circuit protection while reducing the need for separate overcurrent and residual-current protective devices.

This model has a 25 A rated current, B tripping characteristic and Type AC residual-current characteristic with 30 mA sensitivity. Type AC protection responds to sinusoidal alternating residual currents, while the B characteristic is suited to appropriately designed circuits with relatively low starting and inrush currents.

The DS202MACB250.03 provides a 10 kA rated short-circuit breaking capacity, supporting use in installations where robust fault-current interruption is required. Its 2-pole configuration provides simultaneous switching of both conductors, making it a practical protection solution for suitable single-phase final and distribution circuits.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one RCBO.
  • 25 A rated current for appropriately rated circuits and loads.
  • B tripping characteristic for circuits with relatively low starting and inrush currents.
  • Type AC residual-current characteristic for sinusoidal alternating residual currents.
  • 30 mA rated residual operating current.
  • 10 kA breaking capacity for robust short-circuit protection.
  • 2-pole configuration provides switching of both circuit conductors.
  • DIN-rail modular construction supports straightforward integration into distribution equipment.

Key Features

  • ABB DS202 M RCBO.
  • 2-pole configuration.
  • 25 A rated current.
  • B tripping characteristic.
  • Type AC residual-current protection.
  • 30 mA rated residual operating current.
  • 10 kA rated short-circuit breaking capacity.
  • Combined overcurrent and residual-current protection.
  • Modular DIN-rail construction for electrical distribution boards.

Reliable Combined Circuit and Residual-Current Protection

The ABB DS202MACB250.03 integrates the functions of an overcurrent circuit breaker and a residual-current protective device. Its overcurrent section protects against overload and short-circuit conditions, while the residual-current section detects sinusoidal AC leakage currents and disconnects the circuit when the specified residual-current threshold is reached.

Its 30 mA sensitivity provides a high level of residual-current protection, while the 10 kA breaking capacity enables the device to interrupt substantial prospective short-circuit currents within its specified application conditions. The B characteristic makes the RCBO particularly suitable for appropriately designed circuits with relatively low inrush currents.

Typical Applications

  • Single-phase commercial electrical distribution circuits.
  • Residential and light-commercial distribution boards.
  • Final circuits requiring 30 mA residual-current protection.
  • Lighting circuits with relatively low inrush currents.
  • General electrical loads suitable for Type AC residual-current protection.
  • Distribution boards requiring a 10 kA RCBO.
  • DIN-rail switchboards and modular electrical panels.

Technical Specifications

Series DS202 M
SKU DS202MACB250.03
ABB order code 2CSR272001R1255
Product group DS200 / DSH200 RCBO
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 25 A
Tripping characteristic B
Residual-current type AC
Rated residual operating current 30 mA
Rated short-circuit breaking capacity 10 kA
Mounting type DIN rail

Frequently Asked Questions

What is the ABB DS202MACB250.03 used for?

The ABB DS202MACB250.03 is a 2-pole RCBO used to provide combined overload, short-circuit and residual earth-fault protection for suitable electrical circuits.

What is the rated current of the DS202MACB250.03?

The DS202MACB250.03 has a rated current of 25 A and a B tripping characteristic.

What residual-current protection does this RCBO provide?

This model provides Type AC residual-current protection with a rated residual operating current of 30 mA, responding to sinusoidal alternating residual currents.

What is the breaking capacity of the ABB DS202MACB250.03?

The ABB DS202MACB250.03 has a rated short-circuit breaking capacity of 10 kA.

What does the B characteristic mean on this RCBO?

The B tripping characteristic is intended for appropriately designed circuits with relatively low starting and inrush currents, providing overcurrent protection for suitable general-purpose loads.

Trusted ABB Circuit Protection

ABB DS200-series RCBOs combine residual-current and overcurrent protection in modular devices designed for dependable circuit protection in residential, commercial and industrial electrical distribution systems.