2CSR256440R3254 ABB DS203NCC25APR300 DS203NC C25 APR300 3P+N APR RCBO 25A 300mA

2CSR256440R3254 ABB DS203NCC25APR300 DS203NC C25 APR300 3P+N APR RCBO 25A 300mA

ABB DS203NCC25APR300 is a 3P+N APR RCBO with 25 A rated current, C tripping characteristic, 300 mA residual-current sensitivity and 6 kA breaking capacity for high-immunity three-phase circuit protection.

SKU: 2CSR256440R3254Alt SKU: DS203NCC25APR300MPN: 2CSR256440R3254
Price
List Price £329.61 ex VAT
Your Price (ex VAT) Save 35%
£214.25 35% OFF
You save £115.36 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £214.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£214.25

Why Choose the ABB DS203NCC25APR300 RCBO?

The ABB DS203NCC25APR300 is a compact 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase electrical circuits against overloads, short circuits and residual earth-fault currents. As part of the ABB DS203NC series, it combines residual-current and overcurrent protection in a single modular device for efficient commercial and industrial electrical distribution.

This RCBO features a 25 A rated current, C tripping characteristic and APR residual-current characteristic with 300 mA sensitivity. ABB APR technology provides enhanced immunity to transient disturbances that can cause unwanted residual-current tripping, supporting improved continuity of service in installations containing electronic equipment and disturbance-producing loads.

With a rated residual operating current of 300 mA and a rated short-circuit breaking capacity of 6 kA according to EN/IEC 61009, the DS203NCC25APR300 provides coordinated overcurrent and earth-fault protection. Its compact 3P+N four-module construction incorporates three protected poles and a switched neutral, while the C characteristic accommodates moderate starting and inrush currents.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one device.
  • 3P+N configuration for three-phase circuits with neutral.
  • 25 A rated current with C tripping characteristic.
  • 300 mA APR residual-current protection.
  • APR characteristic provides enhanced immunity to transient disturbances and unwanted tripping.
  • 6 kA rated short-circuit breaking capacity according to EN/IEC 61009.
  • Compact four-module format helps conserve distribution-board space.
  • Type C characteristic accommodates moderate starting and inrush currents.
  • DIN-rail construction enables straightforward integration into modular distribution equipment.

Key Features

  • ABB DS203NC RCBO series.
  • 3P+N configuration with three protected poles.
  • 25 A rated current.
  • C tripping characteristic.
  • APR residual-current characteristic.
  • 300 mA rated residual operating current.
  • Enhanced immunity to transient disturbances for reduced unwanted tripping.
  • 400–415 V AC rated voltage.
  • 50/60 Hz rated frequency.
  • 6 kA Icn breaking capacity according to EN/IEC 61009.
  • 10 kA ultimate short-circuit breaking capacity according to IEC 60947-2.
  • Compact four-module DIN-rail format.

Reliable High-Immunity Protection for Three-Phase Circuits

The ABB DS203NCC25APR300 combines the protective functions of a miniature circuit breaker and a residual-current device in one unit. It responds to overload and short-circuit conditions while monitoring residual current flowing to earth, providing coordinated protection for conductors, connected equipment and electrical installations.

Its APR characteristic provides increased immunity to transient disturbances that can cause unwanted operation of conventional residual-current devices. Combined with 300 mA residual-current sensitivity and a C tripping characteristic, the DS203NCC25APR300 is suited to installations requiring earth-fault protection together with improved continuity of service.

Typical Applications

  • Three-phase commercial electrical distribution systems.
  • Industrial electrical distribution boards.
  • Circuits requiring 300 mA residual-current protection.
  • Installations where transient disturbances may cause unwanted residual-current tripping.
  • Machinery and equipment circuits with moderate starting currents.
  • Commercial and industrial circuits containing electronic equipment.
  • Compact switchboards and modular DIN-rail distribution equipment.

Technical Specifications

Series DS203NC
SKU DS203NCC25APR300
ABB order code 2CSR256440R3254
Product group DS200 / DSH200 RCBO
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3P+N / 4 poles
Protected poles 3
Rated current 25 A
Tripping characteristic C
Residual-current characteristic APR
Rated residual operating current 300 mA
Rated voltage 400–415 V AC
Frequency 50/60 Hz
Rated short-circuit breaking capacity Icn 6 kA
Rated ultimate short-circuit breaking capacity Icu 10 kA
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Operating temperature -25 to +55 °C
Mounting type DIN rail
Width 4 modules / 71 mm
Built-in depth 69 mm
Standards IEC/EN 61009-1, IEC/EN 61009-2-1

Frequently Asked Questions

What is the ABB DS203NCC25APR300 used for?

The ABB DS203NCC25APR300 is a 3P+N RCBO designed to protect three-phase circuits against overloads, short circuits and residual earth-fault currents while providing enhanced immunity to unwanted tripping from transient disturbances.

What is the rated current and trip characteristic of the DS203NCC25APR300?

The RCBO has a rated current of 25 A and uses a C tripping characteristic, which accommodates moderate starting and inrush currents.

What residual-current sensitivity does this RCBO provide?

The DS203NCC25APR300 has a rated residual operating current of 300 mA and uses ABB's APR high-immunity residual-current characteristic.

What does APR mean on the ABB DS203NCC25APR300?

ABB's APR characteristic provides increased resistance to unwanted residual-current tripping caused by transient disturbances, helping improve continuity of service in installations susceptible to nuisance tripping.

What is the breaking capacity of the ABB DS203NCC25APR300?

The device has a rated short-circuit breaking capacity Icn of 6 kA according to EN/IEC 61009 and an ultimate short-circuit breaking capacity of 10 kA according to IEC 60947-2.

Trusted ABB Circuit Protection

ABB DS203NC RCBOs combine residual-current and overcurrent protection in a compact modular format, while APR versions provide enhanced immunity to transient disturbances for dependable protection and improved service continuity in three-phase installations.