2CSR256440R1064 ABB DS203NC C6 APR30 RCBO 3P+N 6 A 30 mA

2CSR256440R1064 ABB DS203NC C6 APR30 RCBO 3P+N 6 A 30 mA

ABB DS203NC C6 APR30 is a 6 A 3P+N Type A APR 30 mA high-immunity RCBO with C-curve overcurrent protection and 6 kA short-circuit breaking capacity for commercial and industrial three-phase circuits.

SKU: 2CSR256440R1064Alt SKU: DS203NCC6APR30MPN: 2CSR256440R1064
Price
List Price £299.76 ex VAT
Your Price (ex VAT) Save 35%
£194.84 35% OFF
You save £104.92 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £194.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£194.84

Why Choose the ABB DS203NC C6 APR30 RCBO?

The ABB DS203NC C6 APR30, order code 2CSR256440R1064, is a compact 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase circuits against overloads, short circuits and earth fault currents. Part of the ABB DS200 / DSH200 RCBO product group, this Type A APR device combines residual-current and overcurrent protection in a space-saving four-module format for commercial and industrial electrical installations.

The DS203NC C6 APR30 provides protection against sinusoidal alternating and pulsating DC residual currents while incorporating circuit-breaker protection against overload and short-circuit conditions. Its Type A APR high-immunity characteristic provides enhanced resistance to unwanted tripping, making it particularly useful in installations containing equipment that can produce transient leakage currents or disturbances while maintaining effective residual-current protection.

With a rated current of 6 A, C tripping characteristic, 30 mA rated residual operating current and 6 kA rated short-circuit breaking capacity, the DS203NC C6 APR30 provides comprehensive protection for three-phase systems with neutral. Its compact 3P+N four-module design combines multiple protection functions in a single DIN rail device.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one device.
  • 6 A rated current with C-curve overcurrent tripping characteristic.
  • 30 mA residual current sensitivity provides additional protection against direct contact.
  • Type A detection for sinusoidal AC and pulsating DC residual currents.
  • APR high-immunity design offers increased resistance to unwanted tripping.
  • 3P+N configuration designed for three-phase circuits with neutral.
  • 6 kA rated short-circuit breaking capacity according to IEC/EN 61009-1.
  • Compact four-module construction helps save valuable distribution-board space.

Key Features

  • ABB DS203NC RCBO series.
  • 6 A rated current.
  • C tripping characteristic.
  • 30 mA rated residual current (IΔn).
  • Type A APR residual current protection.
  • High immunity to unwanted tripping with short-time delayed operation.
  • 3P+N pole configuration with three protected poles.
  • 400–415 V AC rated voltage.
  • 6 kA rated short-circuit breaking capacity (Icn).
  • 10 kA rated ultimate short-circuit breaking capacity (Icu).
  • 3 kA maximum surge current withstand.
  • Compact four-module DIN rail format for space-efficient switchboard installation.

High-Immunity Protection for Three-Phase Circuits

An RCBO combines residual-current protection with overload and short-circuit protection within a single device. The ABB DS203NC C6 APR30 therefore protects connected circuits against excessive current while detecting earth leakage that could present an electrical hazard. Its 30 mA residual current sensitivity also provides additional protection against direct contact.

ABB APR devices are designed to provide an optimal balance between safety and continuity of service through enhanced resistance to unwanted tripping. The APR characteristic makes this RCBO particularly suitable for commercial and industrial installations where transient disturbances could cause unnecessary operation of conventional residual-current devices.

Typical Applications

  • Three-phase commercial electrical distribution systems.
  • Industrial distribution boards and switchboards.
  • Circuits requiring combined overcurrent and 30 mA residual-current protection.
  • Installations requiring increased resistance to unwanted RCD tripping.
  • Resistive and inductive three-phase loads.
  • Machinery and industrial equipment distribution circuits.

Technical Specifications

Product group DS200 / DSH200 RCBO
Series DS203NC
ABB order code 2CSR256440R1064
EAN 8012542349822
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3P+N
Protected poles 3
Rated current 6 A
Tripping characteristic C curve
Rated residual current (IΔn) 30 mA
Residual current type Type A APR
Operating characteristic High immunity / short-time delayed
Rated voltage 400–415 V AC
Rated operational voltage 415 V AC
Rated insulation voltage (Ui) 500 V
Rated impulse withstand voltage (Uimp) 4 kV
Rated short-circuit breaking capacity (Icn) 6 kA
Rated ultimate short-circuit breaking capacity (Icu) 10 kA
Maximum surge current 3 kA
Frequency 50 / 60 Hz
Standards IEC 61009-1; IEC 61009-2-1; EN 61009-1; EN 61009-2-1
Application Commercial and industrial installations
Mounting DIN rail
Width 4 modules / 71 mm
Height 85 mm
Depth 69 mm
Weight approx. 0.48 kg

Frequently Asked Questions

What is the ABB DS203NC C6 APR30 used for?

The ABB DS203NC C6 APR30 is a 3P+N RCBO used to protect three-phase circuits against overloads, short circuits and residual earth fault currents in commercial and industrial electrical installations.

What is the current rating of the DS203NC C6 APR30?

The RCBO has a rated current of 6 A and uses a C-curve tripping characteristic.

What residual current sensitivity does this RCBO have?

The DS203NC C6 APR30 has a rated residual operating current of 30 mA and uses Type A APR residual-current protection.

What is the breaking capacity of the ABB DS203NC C6 APR30?

The device has a rated short-circuit breaking capacity (Icn) of 6 kA according to IEC/EN 61009-1 and a rated ultimate short-circuit breaking capacity (Icu) of 10 kA.

What does APR mean on the ABB DS203NC C6 APR30?

APR identifies ABB's high-immunity residual-current characteristic, designed to provide increased resistance to unwanted tripping while maintaining Type A protection against sinusoidal alternating and pulsating DC residual currents.

Trusted ABB Circuit Protection

ABB DS203NC APR RCBOs provide compact combined residual-current and overcurrent protection with enhanced resistance to unwanted tripping, supporting reliable operation in modern commercial and industrial three-phase electrical installations.