2CSR256240R3324 ABB DS203NCC32AS300 DS203NC C32 A S300 3P+N Type A Selective RCBO 32A 300mA

2CSR256240R3324 ABB DS203NCC32AS300 DS203NC C32 A S300 3P+N Type A Selective RCBO 32A 300mA

ABB DS203NCC32AS300 is a 3P+N Type A selective RCBO with 32 A rated current, C tripping characteristic, 300 mA residual-current sensitivity and 6 kA breaking capacity for coordinated three-phase circuit protection.

SKU: 2CSR256240R3324Alt SKU: DS203NCC32AS300MPN: 2CSR256240R3324
Price
List Price £304.25 ex VAT
Your Price (ex VAT) Save 35%
£197.76 35% OFF
You save £106.49 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £197.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£197.76

Why Choose the ABB DS203NCC32AS300 RCBO?

The ABB DS203NCC32AS300 is a compact and dependable 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase electrical circuits against overloads, short circuits and residual earth-fault currents. As part of the ABB DS203NC series, it combines overcurrent and residual-current protection in a single modular device for commercial and industrial electrical distribution.

This RCBO features a 32 A rated current, C tripping characteristic and Type A selective (S) residual-current protection. Type A functionality detects sinusoidal AC and pulsating DC residual currents, while the selective time-delay characteristic supports discrimination with suitable downstream residual-current protective devices.

With a rated residual operating current of 300 mA and a rated short-circuit breaking capacity of 6 kA according to EN/IEC 61009, the DS203NCC32AS300 provides coordinated circuit and earth-fault protection. Its compact 3P+N four-module construction incorporates three protected poles and a switched neutral, making it well suited to three-phase distribution systems requiring selective residual-current protection.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one device.
  • 3P+N configuration for three-phase circuits with neutral.
  • 32 A rated current with C tripping characteristic.
  • 300 mA Type A selective (S) residual-current protection.
  • Selective time-delay operation supports discrimination with downstream residual-current devices.
  • 6 kA rated short-circuit breaking capacity according to EN/IEC 61009.
  • Compact four-module format helps conserve distribution-board space.
  • Type C characteristic accommodates moderate starting and inrush currents.
  • DIN-rail construction enables straightforward integration into modular distribution equipment.

Key Features

  • ABB DS203NC RCBO series.
  • 3P+N configuration with three protected poles.
  • 32 A rated current.
  • C tripping characteristic.
  • Type A selective (S) residual-current characteristic.
  • 300 mA rated residual operating current.
  • 400–415 V AC rated voltage.
  • 50/60 Hz rated frequency.
  • 6 kA Icn breaking capacity according to EN/IEC 61009.
  • 10 kA ultimate short-circuit breaking capacity according to IEC 60947-2.
  • Integrated test functionality for verification of residual-current operation.
  • Compact four-module DIN-rail format.

Reliable Selective Protection for Three-Phase Circuits

RCBOs combine the protective functions of a miniature circuit breaker and a residual-current device in one unit. The ABB DS203NCC32AS300 responds to overload and short-circuit conditions while monitoring residual current flowing to earth, providing coordinated protection for conductors, connected equipment and electrical installations.

The selective Type A characteristic introduces a deliberate time delay in residual-current operation, helping coordinate the DS203NCC32AS300 with suitable downstream residual-current devices. This supports discrimination in multi-level distribution systems by allowing an appropriate downstream protective device to clear a local residual-current fault before the upstream selective RCBO operates.

Typical Applications

  • Three-phase commercial electrical distribution systems.
  • Industrial electrical distribution boards.
  • Distribution circuits requiring selective residual-current protection.
  • Circuits coordinated with downstream RCDs or RCBOs.
  • Machinery and equipment circuits with moderate starting currents.
  • Three-phase loads requiring Type A residual-current detection.
  • Compact switchboards and modular DIN-rail distribution equipment.

Technical Specifications

Series DS203NC
SKU DS203NCC32AS300
ABB order code 2CSR256240R3324
Product group DS200 / DSH200 RCBO
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3P+N / 4 poles
Protected poles 3
Rated current 32 A
Tripping characteristic C
Residual-current type Type A selective (S)
Rated residual operating current 300 mA
Rated voltage 400–415 V AC
Frequency 50/60 Hz
Rated short-circuit breaking capacity Icn 6 kA
Rated ultimate short-circuit breaking capacity Icu 10 kA
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Operating temperature -25 to +55 °C
Mounting type DIN rail
Width 4 modules / 71 mm
Built-in depth 69 mm
Standards IEC/EN 61009-1, IEC/EN 61009-2-1

Frequently Asked Questions

What is the ABB DS203NCC32AS300 used for?

The ABB DS203NCC32AS300 is a 3P+N RCBO used to protect three-phase circuits against overloads, short circuits and residual earth-fault currents while providing selective residual-current operation.

What is the rated current and trip characteristic of the DS203NCC32AS300?

The RCBO has a rated current of 32 A and uses a C tripping characteristic.

What residual-current protection does this RCBO provide?

The DS203NCC32AS300 provides Type A selective (S) residual-current protection with a rated residual operating current of 300 mA.

What does the selective S characteristic mean?

The selective S characteristic provides time-delayed residual-current operation to support discrimination with suitable downstream residual-current protective devices.

What is the breaking capacity of the ABB DS203NCC32AS300?

The device has a rated short-circuit breaking capacity Icn of 6 kA according to EN/IEC 61009 and an ultimate short-circuit breaking capacity of 10 kA according to IEC 60947-2.

Trusted ABB Circuit Protection

ABB DS203NC RCBOs combine residual-current and overcurrent protection in a compact modular format, supporting dependable and coordinated protection in modern three-phase commercial and industrial electrical installations.