2CSR256240R2324 ABB DS203NC C32 A S100 RCBO 3P+N 32 A 100 mA

2CSR256240R2324 ABB DS203NC C32 A S100 RCBO 3P+N 32 A 100 mA

ABB DS203NC C32 A S100 is a 32 A 3P+N Type A selective 100 mA RCBO with C-curve overcurrent protection and 6 kA short-circuit breaking capacity for commercial and industrial three-phase circuits.

SKU: 2CSR256240R2324Alt SKU: DS203NCC32AS100MPN: 2CSR256240R2324
Price
List Price £304.25 ex VAT
Your Price (ex VAT) Save 35%
£197.76 35% OFF
You save £106.49 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £197.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£197.76

Why Choose the ABB DS203NC C32 A S100 RCBO?

The ABB DS203NC C32 A S100, order code 2CSR256240R2324, is a compact 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase circuits against overloads, short circuits and earth fault currents. Part of the ABB DS200 / DSH200 RCBO product group, this selective Type A device combines residual current and overcurrent protection in a space-saving four-module format for commercial and industrial electrical installations.

The DS203NC provides protection against sinusoidal alternating and pulsating DC residual currents while incorporating circuit-breaker protection against overload and short-circuit conditions. Its Type A residual current characteristic makes it suitable for modern electrical loads capable of producing pulsating DC earth fault currents, while the selective S-type characteristic supports coordinated residual-current protection and improved continuity of service.

With a rated current of 32 A, C tripping characteristic, 100 mA rated residual operating current and 6 kA rated short-circuit breaking capacity, the DS203NC C32 A S100 provides comprehensive circuit protection for three-phase systems with neutral. Its compact 3P+N four-module design reduces the distribution-board space required compared with separate residual-current and overcurrent protection devices.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one device.
  • 32 A rated current with C-curve overcurrent tripping characteristic.
  • 100 mA residual current sensitivity for earth fault protection.
  • Type A detection for sinusoidal AC and pulsating DC residual currents.
  • Selective S-type operation for coordinated residual-current protection.
  • 3P+N configuration for modern three-phase electrical systems.
  • 6 kA rated short-circuit breaking capacity according to IEC/EN 61009-1.
  • Compact four-module construction helps save valuable distribution-board space.

Key Features

  • ABB DS203NC RCBO series.
  • 32 A rated current.
  • C tripping characteristic.
  • 100 mA rated residual current (IΔn).
  • Type A residual current protection.
  • Selective S-type characteristic.
  • 3P+N pole configuration with three protected poles and four-pole switching.
  • 6 kA rated short-circuit breaking capacity (Icn).
  • Test pushbutton for verification of correct residual-current protection operation.
  • Earth fault indicator assists with rapid identification of residual-current trips.
  • Contact position indicator provides clear visual indication of contact status.
  • Compact four-module DIN rail format for space-efficient switchboard installation.

Combined Protection for Three-Phase Circuits

An RCBO combines the functions of residual-current protection and overcurrent protection within a single device. The ABB DS203NC C32 A S100 therefore protects connected circuits against overload and short-circuit currents while also detecting earth leakage currents that could create electrical hazards, equipment damage or electrically initiated fires.

The DS203NC range is designed for modern three-phase installations where switchboard space, protection and continuity of operation are important. Its compact four-module construction can reduce the space required by approximately 50% compared with an RCD plus MCB configuration, while the earth fault indicator and contact position indicator simplify fault identification, inspection and maintenance.

Typical Applications

  • Three-phase commercial electrical distribution systems.
  • Industrial distribution boards and switchboards.
  • Three-phase circuits requiring combined overcurrent and earth fault protection.
  • Electrical installations requiring selective residual-current protection.
  • Machinery and industrial equipment distribution circuits.
  • Commercial and industrial installations where distribution-board space is limited.

Technical Specifications

Product group DS200 / DSH200 RCBO
Series DS203NC
ABB order code 2CSR256240R2324
EAN 8012542021520
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3P+N
Protected poles 3
Rated current 32 A
Tripping characteristic C curve
Rated residual current (IΔn) 100 mA
Residual current type Type A
Selective characteristic S type
Rated short-circuit breaking capacity (Icn) 6 kA
Impulse current withstand 5 kA (8/20 µs)
Standards IEC/EN 61009-1
Application Commercial and industrial installations
Mounting DIN rail
Width 4 modules
Weight approx. 0.48 kg

Frequently Asked Questions

What is the ABB DS203NC C32 A S100 used for?

The ABB DS203NC C32 A S100 is a 3P+N RCBO used to protect three-phase circuits against overloads, short circuits and residual earth fault currents in commercial and industrial electrical installations.

What is the current rating of the DS203NC C32 A S100?

The RCBO has a rated current of 32 A and uses a C-curve tripping characteristic.

What residual current sensitivity does this RCBO have?

The DS203NC C32 A S100 has a rated residual operating current of 100 mA and is a Type A selective S-type device.

What is the breaking capacity of the ABB DS203NC C32 A S100?

The device has a rated short-circuit breaking capacity (Icn) of 6 kA according to IEC/EN 61009-1.

What does Type A S mean on this ABB RCBO?

Type A indicates detection of sinusoidal alternating and pulsating DC residual currents, while the S designation identifies the device as a selective residual-current protective device designed to support coordinated protection and continuity of service within an electrical installation.

Trusted ABB Circuit Protection

ABB DS203NC RCBOs provide compact combined residual-current and overcurrent protection for modern three-phase electrical installations, helping electrical engineers and installers achieve reliable circuit protection while minimising distribution-board space.