2CSR256140R3204 ABB DS203NCC20A300 RCBO 3P+N C20 Type A 300 mA

2CSR256140R3204 ABB DS203NCC20A300 RCBO 3P+N C20 Type A 300 mA

ABB DS203NCC20A300 is a 20 A 3P+N C-curve Type A RCBO with 300 mA residual current sensitivity and 6 kA short-circuit capacity for three-phase electrical circuit protection.

SKU: 2CSR256140R3204Alt SKU: DS203NCC20A300MPN: 2CSR256140R3204
Price
List Price £253.65 ex VAT
Your Price (ex VAT) Save 35%
£164.87 35% OFF
You save £88.78 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £164.87
Trade pricing is personalised to your account

Manufacturer Lead Time

£164.87

Why Choose the ABB DS203NCC20A300 RCBO?

The ABB DS203NCC20A300 is a compact and reliable 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and earth leakage currents in three-phase electrical installations. As part of the ABB DS203NC series, it combines residual current and overcurrent protection within a four-module device, helping reduce panel space and simplify distribution board design.

This RCBO features a Type C tripping characteristic, a 20 A rated current and Type A residual current protection. Type A detection provides protection against sinusoidal AC residual currents as well as pulsating DC residual currents, making the device suitable for a wide range of modern electrical loads and installations.

With a rated residual operating current of 300 mA and a rated short-circuit capacity of 6 kA, the DS203NCC20A300 provides dependable circuit and earth-fault protection for three-phase systems. Its DIN-rail format and four-module width make it suitable for distribution boards, control panels and commercial or industrial electrical installations.

Key Advantages

  • Combined residual current and overcurrent protection in one compact RCBO.
  • 3P+N configuration for three-phase circuits with neutral.
  • 20 A rated current with Type C tripping characteristic.
  • 300 mA Type A residual current protection.
  • 6 kA rated short-circuit capacity.
  • Compact four-module DIN-rail design helps optimise distribution board space.
  • Protects against overload, short-circuit and residual earth-fault currents.

Key Features

  • ABB DS203NC RCBO series.
  • 20 A rated current.
  • Type C tripping characteristic.
  • Type A residual current detection.
  • 300 mA rated residual operating current.
  • 3P+N, four-pole configuration.
  • 6 kA rated short-circuit capacity.
  • 10 kA ultimate short-circuit breaking capacity.
  • 50 / 60 Hz rated frequency.
  • DIN-rail mounting for modular electrical distribution systems.

Combined Circuit and Residual Current Protection

RCBOs such as the ABB DS203NC combine the functions of a miniature circuit breaker and residual current protective device in a single unit. This allows one device to protect a circuit against overload and short-circuit conditions while also detecting residual currents caused by insulation faults or current leakage to earth.

The DS203NCC20A300 uses Type A residual current detection and a C-curve overcurrent characteristic. Type A technology detects sinusoidal AC and pulsating DC residual currents, while the C-curve characteristic makes the device suitable for circuits with moderate inrush currents found in many commercial and industrial electrical loads.

Typical Applications

  • Three-phase electrical distribution boards.
  • Commercial and industrial electrical installations.
  • Machinery and automation control panels.
  • Three-phase circuits requiring combined overcurrent and earth-leakage protection.
  • Building services and electrical distribution systems.
  • Circuits containing electronic equipment capable of producing pulsating DC residual currents.

Technical Specifications

Series DS203NC
Product group DS200 / DSH200 RCBO
ABB order code 2CSR256140R3204
EAN / GTIN 8012542831020
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3P+N / 4 poles
Protected poles 3
Rated current 20 A
Tripping characteristic C curve
Residual current type Type A
Rated residual operating current 300 mA
Rated frequency 50 / 60 Hz
Rated short-circuit capacity 6 kA
Ultimate short-circuit breaking capacity 10 kA
Service short-circuit breaking capacity 6 kA
Protection rating IP2X
Pollution degree 2
Overvoltage category III
Energy limiting class 3
Residual current operating characteristic Undelayed
Neutral conductor switching Yes
Terminal capacity, solid conductor up to 25 mm²
Terminal capacity, multi-wired conductor up to 25 mm²
Mounting type DIN rail
Module width 4 modules
Built-in depth 69 mm
Weight approx. 0.48 kg

Frequently Asked Questions

What is the ABB DS203NCC20A300 used for?

The ABB DS203NCC20A300 is a 3P+N RCBO used to protect three-phase electrical circuits against overloads, short circuits and residual earth-fault currents.

What is the current rating of the DS203NCC20A300?

The DS203NCC20A300 has a rated current of 20 A and uses a Type C tripping characteristic.

What residual current sensitivity does this RCBO provide?

This model has a rated residual operating current of 300 mA and provides Type A residual current protection.

What is the short-circuit rating of the ABB DS203NCC20A300?

The RCBO has a rated short-circuit capacity of 6 kA and an ultimate short-circuit breaking capacity of 10 kA.

How many poles does the DS203NCC20A300 have?

The DS203NCC20A300 is a 3P+N four-pole RCBO with three protected poles, designed for three-phase circuits with a neutral conductor.

Trusted ABB Circuit Protection

ABB DS203NC residual current circuit breakers with overcurrent protection combine compact modular construction with dependable overload, short-circuit and residual current protection for modern three-phase electrical distribution systems.