2CSR256140R3135 ABB DS203NCB13A300 RCBO 3P+N B13 Type A 300 mA

2CSR256140R3135 ABB DS203NCB13A300 RCBO 3P+N B13 Type A 300 mA

ABB DS203NCB13A300 is a 13 A 3P+N B-curve Type A RCBO with 300 mA residual current sensitivity and 6 kA short-circuit capacity for three-phase electrical circuit protection.

SKU: 2CSR256140R3135Alt SKU: DS203NCB13A300MPN: 2CSR256140R3135
Price
List Price £279.00 ex VAT
Your Price (ex VAT) Save 35%
£181.35 35% OFF
You save £97.65 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £181.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£181.35

Why Choose the ABB DS203NCB13A300 RCBO?

The ABB DS203NCB13A300 is a compact and reliable 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and earth leakage currents in three-phase electrical installations. As part of the ABB DS203NC series, it combines residual current and overcurrent protection within a four-module device, helping reduce panel space and simplify distribution board design.

This RCBO features a Type B tripping characteristic, a 13 A rated current and Type A residual current protection. Type A detection provides protection against sinusoidal AC residual currents as well as pulsating DC residual currents, making the device suitable for a wide range of modern electrical loads and installations.

With a rated residual operating current of 300 mA, a rated short-circuit capacity of 6 kA and a rated operational voltage of 415 V AC, the DS203NCB13A300 provides dependable circuit and earth-fault protection for three-phase systems. Its DIN-rail format and four-module width make it suitable for distribution boards, control panels and commercial or industrial electrical installations.

Key Advantages

  • Combined residual current and overcurrent protection in one compact RCBO.
  • 3P+N configuration for three-phase circuits with neutral.
  • 13 A rated current with Type B tripping characteristic.
  • 300 mA Type A residual current protection.
  • 6 kA rated short-circuit capacity.
  • Compact four-module DIN-rail design helps optimise distribution board space.
  • Protects against overload, short-circuit and residual earth-fault currents.

Key Features

  • ABB DS203NC RCBO series.
  • 13 A rated current.
  • Type B tripping characteristic.
  • Type A residual current detection.
  • 300 mA rated residual operating current.
  • 3P+N, four-pole configuration.
  • 415 V AC rated operational voltage.
  • 6 kA rated short-circuit capacity.
  • 50 / 60 Hz rated frequency.
  • DIN-rail mounting for modular electrical distribution systems.

Combined Circuit and Residual Current Protection

RCBOs such as the ABB DS203NC combine the functions of a miniature circuit breaker and residual current protective device in a single unit. This allows one device to protect a circuit against overload and short-circuit conditions while also detecting residual currents caused by insulation faults or current leakage to earth.

The DS203NCB13A300 uses Type A residual current detection and a B-curve overcurrent characteristic. Type A technology detects sinusoidal AC and pulsating DC residual currents, while the B-curve characteristic provides rapid magnetic operation for circuits where high starting currents are not normally expected.

Typical Applications

  • Three-phase electrical distribution boards.
  • Commercial and industrial electrical installations.
  • Machinery and automation control panels.
  • Three-phase circuits requiring combined overcurrent and earth-leakage protection.
  • Building services and electrical distribution systems.
  • Circuits containing electronic equipment capable of producing pulsating DC residual currents.

Technical Specifications

Series DS203NC
Product group DS200 / DSH200 RCBO
ABB order code 2CSR256140R3135
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3P+N / 4 poles
Protected poles 3
Rated current 13 A
Tripping characteristic B curve
Residual current type Type A
Rated residual operating current 300 mA
Rated operational voltage 415 V AC
Rated frequency 50 / 60 Hz
Rated short-circuit capacity 6 kA
Ultimate short-circuit breaking capacity 10 kA
Rated conditional short-circuit current 10 kA
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Protection rating IP2X
Pollution degree 2
Overvoltage category III
Current limiting class 3
Operating temperature -25 to +55 °C
Terminal capacity up to 25 mm²
Mounting type DIN rail
Module width 4 modules
Dimensions (H × W × D) 85 × 71 × 69 mm
Weight approx. 0.48 kg
Standards IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1

Frequently Asked Questions

What is the ABB DS203NCB13A300 used for?

The ABB DS203NCB13A300 is a 3P+N RCBO used to protect three-phase electrical circuits against overloads, short circuits and residual earth-fault currents.

What is the current rating of the DS203NCB13A300?

The DS203NCB13A300 has a rated current of 13 A and uses a Type B tripping characteristic.

What residual current sensitivity does this RCBO provide?

This model has a rated residual operating current of 300 mA and provides Type A residual current protection.

What is the short-circuit rating of the ABB DS203NCB13A300?

The RCBO has a rated short-circuit capacity of 6 kA, with an ultimate short-circuit breaking capacity of 10 kA.

How many poles does the DS203NCB13A300 have?

The DS203NCB13A300 is a 3P+N four-pole RCBO with three protected poles, designed for three-phase circuits with a neutral conductor.

Trusted ABB Circuit Protection

ABB DS203NC residual current circuit breakers with overcurrent protection combine compact modular construction with dependable overload, short-circuit and residual current protection for modern three-phase electrical distribution systems.