2CSR256140R2324 ABB Residual Current Circuit Breaker with Overcurrent Protection DS203NC - 3P+N - 100 mA - 32 A - C - Type A

2CSR256140R2324 ABB Residual Current Circuit Breaker with Overcurrent Protection DS203NC – 3P+N – 100 mA – 32 A – C – Type A

ABB 2CSR256140R2324 DS203NC C32 A100 compact 3P+N RCBO with a 32 A rated current, C tripping characteristic, Type A residual current detection and 100 mA sensitivity.

SKU: 2CSR256140R2324Alt SKU: DS203NC C32 A100MPN: 2CSR256140R2324
Price
List Price £253.65 ex VAT
Your Price (ex VAT) Save 35%
£164.87 35% OFF
You save £88.78 per unit
In stock. Ships today if ordered before 2pm
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £164.87
Trade pricing is personalised to your account

12 in stock (can be backordered)

£164.87

Why Choose the ABB DS203NC C32 A100 RCBO?

The ABB 2CSR256140R2324, also identified as the DS203NC C32 A100, is a compact residual current circuit breaker with overcurrent protection (RCBO) designed for three-phase electrical distribution systems. Combining residual current, overload and short-circuit protection in one device, it helps safeguard electrical equipment, installations and users while reducing the space required inside distribution boards.

As part of ABB's System pro M compact DS203NC series, this RCBO features a 3P+N configuration within a compact four-module housing. It provides protection for all three phase conductors while switching the neutral conductor, making it suitable for commercial, industrial and infrastructure applications where reliable protection and efficient panel design are essential.

The DS203NC C32 A100 has a rated current of 32 A, a C tripping characteristic and a rated residual operating current of 100 mA. Its Type A residual current detection responds to sinusoidal AC and pulsating DC residual currents, while its rated operating voltage of 400–415 V AC supports standard three-phase power distribution systems.

Key Advantages

  • Combines residual current, overload and short-circuit protection in one device.
  • Compact 3P+N RCBO occupying four DIN modules.
  • 32 A rated current for three-phase distribution circuits.
  • 100 mA residual operating current for earth leakage protection.
  • Type A residual current detection for AC and pulsating DC fault currents.
  • C-curve tripping characteristic suitable for circuits with moderate inrush currents.
  • High electrical and mechanical endurance for dependable operation.
  • Compatible with ABB System pro M compact accessories.

Key Features

  • ABB DS203NC compact RCBO series.
  • 3P+N configuration with three protected poles.
  • 32 A rated current.
  • 100 mA rated residual current.
  • Type A leakage current sensitivity.
  • C tripping characteristic.
  • 400–415 V AC rated operating voltage.
  • 6 kA rated short-circuit capacity at 230/400 V AC.
  • 10 kA ultimate short-circuit breaking capacity.
  • DIN rail mounting for modular distribution boards.
  • Neutral terminal positioned on the right.
  • Undelayed residual current operating characteristic.

Combined Protection for Three-Phase Circuits

The ABB DS203NC C32 A100 monitors current flowing through the phase and neutral conductors while also protecting the circuit against excessive load and short-circuit currents. When a qualifying earth leakage, overload or short-circuit fault is detected, the device automatically disconnects the circuit to help reduce the risk of equipment damage, electric shock and electrical fires.

Its four-module design provides a space-efficient alternative to installing separate miniature circuit breakers and residual current devices. This makes the RCBO particularly valuable in compact switchboards, retrofit projects and distribution panels where available DIN rail space is limited.

Typical Applications

  • Three-phase commercial distribution circuits.
  • Industrial sockets and machinery supplies.
  • Temporary electrical installations and site distribution boards.
  • Power generator distribution circuits.
  • Marinas, campsites and outdoor electrical infrastructure.
  • Workshops and light industrial facilities.
  • Commercial buildings and service installations.
  • Retrofit projects requiring combined residual current and overcurrent protection.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 32 A
Phase Three Phase
Device Type RCBO
Trip Curve C curve
Breaking Capacity 6 kA
Residual Current 100 mA
RCD Type Type A
Manufacturer ABB
Series DS203NC
Model DS203NC C32 A100
Product ID 2CSR256140R2324
Product type Residual current circuit breaker with overcurrent protection
Device abbreviation RCBO
Number of poles 4
Configuration 3P+N
Number of protected poles 3
Rated current 32 A
Tripping characteristic C
Residual current type Type A
Rated residual current 100 mA
Rated voltage 400–415 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Rated frequency 50 / 60 Hz
Rated short-circuit capacity 6 kA at 230 / 400 V AC
Ultimate short-circuit breaking capacity 10 kA
Conditional short-circuit current 10 kA
Service short-circuit breaking capacity 6 kA
Energy limiting class 3
Overvoltage category III
Residual current operation Undelayed
Electrical endurance 10,000 cycles
Mechanical endurance 20,000 cycles
Power loss 15.1 W
Mounting type DIN rail
Module width 4 modules
Terminal capacity Up to 25 mm² rigid or flexible conductor
Standards IEC/EN 61009-1 and IEC/EN 61009-2-1
EAN 8012542831129
Weight Approx. 0.47 kg
HS Code 85363030
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 2CSR256140R2324 used for?

It protects three-phase electrical circuits against earth leakage, overloads and short circuits in commercial, industrial and infrastructure installations.

What is the rated current of this RCBO?

The ABB DS203NC C32 A100 has a rated current of 32 A and a C-curve tripping characteristic.

What residual current sensitivity does it provide?

The device has a rated residual operating current of 100 mA and uses Type A residual current detection.

How many poles does the device have?

It has a 3P+N configuration with four poles in total and overcurrent protection applied to the three phase conductors.

How much space does the RCBO require?

The DS203NC occupies four DIN modules, providing combined residual current and overcurrent protection in a compact format.

Trusted ABB Circuit Protection

ABB DS203NC RCBOs provide compact and dependable protection for three-phase circuits, helping electrical engineers and panel builders create safe, space-efficient distribution systems.