2CSR256140R2164 ABB Residual Current Circuit Breaker with Overcurrent Protection DS203NC - 3P+N - 100 mA - 16 A - C - Type A

2CSR256140R2164 ABB Residual Current Circuit Breaker with Overcurrent Protection DS203NC – 3P+N – 100 mA – 16 A – C – Type A

ABB DS203NC C16 A100 3P+N RCBO with 16 A rated current, 100 mA Type A residual current protection and C tripping characteristic.

SKU: 2CSR256140R2164Alt SKU: DS203NC C16 A100MPN: 2CSR256140R2164
Price
List Price £253.65 ex VAT
Your Price (ex VAT) Save 35%
£164.87 35% OFF
You save £88.78 per unit
In stock. Ships today if ordered before 2pm
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £164.87
Trade pricing is personalised to your account

12 in stock (can be backordered)

£164.87

Why Choose the ABB DS203NC C16 A100 RCBO?

The ABB 2CSR256140R2164, also identified as the DS203NC C16 A100, is a high quality residual current circuit breaker with overcurrent protection (RCBO) designed for three-phase electrical installations. Combining residual current, overload and short-circuit protection in a single compact device, it provides comprehensive protection for electrical systems while reducing the space required within distribution boards.

Part of ABB's proven System pro M compact DS203NC series, this RCBO features a 3P+N configuration housed within four DIN modules. It protects all three phase conductors against overload and short-circuit faults while monitoring earth leakage across the complete circuit, making it suitable for commercial, industrial and infrastructure applications.

The DS203NC C16 A100 has a rated current of 16 A, a C tripping characteristic and a rated residual operating current of 100 mA. Its Type A residual current detection responds to sinusoidal AC and pulsating DC residual currents, while operating from a standard 400–415 V AC three-phase supply.

Key Advantages

  • Combines earth leakage, overload and short-circuit protection in one compact device.
  • 16 A rated current suitable for three-phase distribution circuits.
  • 100 mA residual current sensitivity.
  • Type A residual current detection for AC and pulsating DC leakage currents.
  • C-curve tripping characteristic for circuits with moderate inrush currents.
  • Compact four-module design saves valuable DIN rail space.
  • High electrical and mechanical endurance.
  • Compatible with ABB System pro M compact accessories.

Key Features

  • ABB DS203NC RCBO series.
  • 3P+N configuration.
  • 16 A rated current.
  • 100 mA rated residual current.
  • Type A residual current protection.
  • C tripping characteristic.
  • 400–415 V AC rated voltage.
  • 6 kA rated short-circuit capacity.
  • 10 kA ultimate breaking capacity.
  • DIN rail mounting.
  • Neutral terminal positioned on the right.
  • Manufactured to IEC/EN 61009 standards.

Comprehensive Protection for Three-Phase Installations

The ABB DS203NC C16 A100 continuously monitors current flowing through the protected conductors while providing automatic disconnection in the event of overloads, short circuits or earth leakage faults. This integrated protection helps improve electrical safety while protecting valuable equipment and reducing installation complexity.

Its compact four-module construction makes it an excellent choice for modern distribution boards where space efficiency and dependable circuit protection are equally important.

Typical Applications

  • Commercial electrical distribution.
  • Industrial machinery supplies.
  • Three-phase socket outlets.
  • Control panels and switchboards.
  • Infrastructure projects.
  • Renewable energy systems.
  • Workshop electrical installations.
  • Distribution boards requiring combined RCBO protection.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 16 A
Phase Three Phase
Device Type RCBO
Trip Curve C curve
Breaking Capacity 6 kA
Residual Current 100 mA
RCD Type Type A
Manufacturer ABB
Series DS203NC
Model DS203NC C16 A100
Product ID 2CSR256140R2164
EAN 8012542839828
Product type Residual current circuit breaker with overcurrent protection
Configuration 3P+N
Number of poles 4
Protected poles 3
Rated current 16 A
Tripping characteristic C
Residual current type Type A
Rated residual operating current 100 mA
Rated voltage 400–415 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Rated frequency 50 / 60 Hz
Rated short-circuit capacity 6 kA
Ultimate short-circuit breaking capacity 10 kA
Energy limiting class 3
Overvoltage category III
Electrical endurance 10,000 operations
Mechanical endurance 20,000 operations
Mounting type DIN rail
Module width 4 modules
Standards IEC/EN 61009-1, IEC/EN 61009-2-1
HS Code 85363010
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 2CSR256140R2164 used for?

It protects three-phase electrical circuits against earth leakage, overloads and short circuits using a single compact RCBO.

What is the rated current?

The ABB DS203NC C16 A100 has a rated current of 16 A.

What residual current sensitivity does it provide?

The device has a rated residual operating current of 100 mA with Type A residual current detection.

How many poles does the RCBO have?

It features a 3P+N configuration with four poles and protection applied to the three phase conductors.

How is the device installed?

The RCBO is designed for quick installation onto a standard DIN rail within electrical distribution boards.

Trusted ABB Electrical Protection

ABB DS203NC RCBOs are trusted by electrical contractors, panel builders and industrial engineers for providing dependable combined residual current and overcurrent protection in three-phase electrical systems.