2CSR256040R3164 ABB DS203NCC16AC300 RCBO 3P+N C16 Type AC 300mA 6kA

2CSR256040R3164 ABB DS203NCC16AC300 RCBO 3P+N C16 Type AC 300mA 6kA

ABB DS203NCC16AC300 is a 16 A 3P+N Type C RCBO with 300 mA Type AC residual-current protection, 400–415 V AC operation and a 6 kA rated short-circuit breaking capacity.

SKU: 2CSR256040R3164Alt SKU: DS203NCC16AC300MPN: 2CSR256040R3164
Price
List Price £211.33 ex VAT
Your Price (ex VAT) Save 35%
£137.36 35% OFF
You save £73.97 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £137.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£137.36

Why Choose the ABB DS203NCC16AC300 RCBO?

The ABB DS203NCC16AC300 is a compact and reliable 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase electrical circuits against overloads, short circuits and residual earth-fault currents. As part of the ABB DS203NC RCBO series, it combines residual-current and overcurrent protection within a single four-module device for efficient electrical distribution installations.

This RCBO has a rated current of 16 A, a Type C tripping characteristic and a rated residual operating current of 300 mA. Its Type AC residual-current characteristic provides detection of sinusoidal alternating residual currents, making the device suitable for appropriate AC circuits where this form of residual-current protection is specified.

With a rated operational voltage of 400–415 V AC and a rated short-circuit breaking capacity of 6 kA according to EN 61009, the DS203NC C16 AC300 provides coordinated protection for three-phase plus neutral circuits. Its compact four-module DIN-rail format helps conserve switchboard space while integrating multiple circuit-protection functions into a single device.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one device.
  • 16 A rated current with Type C tripping characteristic.
  • 300 mA rated residual operating current.
  • Type AC residual-current detection for sinusoidal alternating residual currents.
  • 3P+N configuration for three-phase circuits with neutral.
  • 6 kA rated short-circuit breaking capacity according to EN 61009.

Key Features

  • ABB DS203NC RCBO series.
  • 16 A rated current.
  • Type C tripping curve.
  • 300 mA residual-current sensitivity.
  • Type AC residual-current characteristic.
  • 3P+N four-pole configuration with three protected poles.
  • 400–415 V AC rated operational voltage.
  • 6 kA rated short-circuit breaking capacity.
  • 50 / 60 Hz operating frequency.
  • Compact four-module DIN-rail design.

Reliable Protection for Three-Phase Circuits

RCBOs such as the ABB DS203NCC16AC300 combine the functions of an overcurrent protective device and a residual-current protective device in a single unit. This allows the circuit breaker to respond to overload and short-circuit conditions while its residual-current function detects earth-fault currents, providing coordinated protection for suitable three-phase electrical circuits.

The DS203NC series is designed for compact three-phase distribution systems. Its 3P+N arrangement and four-module construction help reduce panel space compared with separate protective devices, while the Type C overcurrent characteristic is suitable for circuits where moderate inrush currents may occur during normal operation.

Typical Applications

  • Three-phase electrical distribution circuits.
  • Commercial and industrial distribution boards.
  • Electrical control panels and switchboards.
  • Three-phase circuits requiring 3P+N protection.
  • Circuits requiring combined overcurrent and residual-current protection.
  • Building services and infrastructure electrical systems.

Technical Specifications

Series DS203NC
SKU DS203NCC16AC300
ABB order code 2CSR256040R3164
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Rated current 16 A
Tripping characteristic C
Rated residual operating current 300 mA
Residual-current type AC
Number of poles 4 (3P+N)
Number of protected poles 3
Rated voltage 400–415 V AC
Rated operational voltage 400–415 V AC
Frequency 50 / 60 Hz
Rated short-circuit breaking capacity (Icn) 6 kA
Short-circuit breaking capacity according to IEC 60947-2 10 kA
Rated insulation voltage (Ui) 500 V
Rated impulse withstand voltage (Uimp) 4 kV
Current limiting class 3
Tripping Undelayed
Surge current capacity 0.25 kA
Overvoltage category III
Pollution degree 2
Protection rating IP2X
Neutral conductor Concurrently switched
Maximum connectable conductor cross-section 25 mm²
Mounting type DIN rail
Width 4 modular spacings
Built-in depth 69 mm
Weight approx. 0.480 kg
Standards IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1
EAN 8012542185529

Frequently Asked Questions

What is the ABB DS203NCC16AC300 used for?

The ABB DS203NCC16AC300 is an RCBO designed to protect suitable three-phase plus neutral electrical circuits against overloads, short circuits and residual earth-fault currents.

What is the rated current of the DS203NCC16AC300?

The RCBO has a rated current of 16 A and uses a Type C tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The DS203NCC16AC300 has a rated residual operating current of 300 mA and uses a Type AC residual-current characteristic.

What is the breaking capacity of the ABB DS203NCC16AC300?

The device has a rated short-circuit breaking capacity of 6 kA according to EN 61009.

How many poles does the DS203NCC16AC300 have?

The device has a 3P+N four-pole configuration with three protected poles and a concurrently switched neutral conductor.

Trusted ABB Circuit Protection

ABB DS203NC residual current circuit breakers with overcurrent protection provide compact combined protection for modern three-phase electrical distribution systems, integrating overcurrent and earth-fault protection in a space-saving four-module design.