2CSR256040R3064 ABB DS203NCC6AC300 RCBO 3P+N C6 AC 300mA 6kA

2CSR256040R3064 ABB DS203NCC6AC300 RCBO 3P+N C6 AC 300mA 6kA

ABB DS203NCC6AC300 is a 6 A 3P+N Type AC RCBO with C-curve overcurrent protection, 300 mA residual current sensitivity and 6 kA short-circuit breaking capacity according to IEC/EN 61009 for commercial and industrial three-phase circuits.

SKU: 2CSR256040R3064Alt SKU: DS203NCC6AC300MPN: 2CSR256040R3064
Price
List Price £211.33 ex VAT
Your Price (ex VAT) Save 35%
£137.36 35% OFF
You save £73.97 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £137.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£137.36

Why Choose the ABB DS203NCC6AC300 RCBO?

The ABB DS203NCC6AC300 is a compact 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase electrical circuits against overloads, short circuits and earth fault currents. As part of the ABB DS203NC range, it combines residual current and overcurrent protection in a space-saving four-module device for commercial and industrial electrical distribution systems.

With a 6 A rated current, C tripping characteristic and 300 mA residual current sensitivity, the DS203NC C6 AC300 provides coordinated protection against overcurrent and sinusoidal alternating residual currents. Its Type AC residual current detection is intended for circuits where sinusoidal AC earth leakage currents are expected.

The DS203NCC6AC300 provides a 6 kA rated short-circuit breaking capacity according to IEC/EN 61009 and is designed for three-phase circuits with neutral. Its compact DIN-rail construction combines multiple protection functions in one device, helping simplify distribution-board design and conserve installation space.

Key Advantages

  • Combined residual current and overcurrent protection in one compact device.
  • 6 A rated current for lower-current three-phase circuits.
  • C tripping characteristic suitable for circuits with moderate inrush currents.
  • 300 mA residual current sensitivity for earth fault protection.
  • Type AC detection for sinusoidal alternating residual currents.
  • 6 kA rated short-circuit breaking capacity according to IEC/EN 61009.
  • Compact 3P+N four-module design helps conserve DIN-rail space.

Key Features

  • ABB DS203NC RCBO range.
  • 3P+N configuration.
  • 6 A rated current.
  • C curve tripping characteristic.
  • 300 mA rated residual operating current.
  • Type AC residual current protection.
  • 6 kA breaking capacity according to IEC/EN 61009.
  • Combined overload, short-circuit and residual current protection.
  • Compact four-module construction.
  • DIN-rail mounting for electrical distribution boards.

Reliable Combined Protection for Three-Phase Circuits

An RCBO combines miniature circuit-breaker and residual current protection within a single device. The ABB DS203NC C6 AC300 therefore protects connected circuits against overload and short-circuit currents while also detecting sinusoidal alternating earth fault currents.

The DS203NC series is designed for three-phase commercial and industrial installations where comprehensive circuit protection and efficient use of distribution-board space are important. The C-curve characteristic accommodates moderate starting currents, while the 300 mA residual current rating provides earth fault protection for suitable applications.

Typical Applications

  • Commercial three-phase electrical distribution systems.
  • Industrial control panels and distribution boards.
  • Lower-current three-phase circuits.
  • Machinery and automation power distribution.
  • Building services and electrical installations.
  • DIN-rail switchboards requiring combined residual current and overcurrent protection.

Technical Specifications

Series DS203NC
ABB order code 2CSR256040R3064
Product group DS200 / DSH200 RCBO
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3P+N
Rated current 6 A
Tripping characteristic C curve
Residual current type AC
Rated residual current 300 mA
Rated short-circuit breaking capacity 6 kA according to IEC/EN 61009
Maximum operating voltage 415 V AC
Width 4 modules
Mounting type DIN rail
Standard IEC/EN 61009

Frequently Asked Questions

What is the ABB DS203NCC6AC300 used for?

The DS203NCC6AC300 is a 3P+N RCBO designed to protect three-phase circuits against overloads, short circuits and sinusoidal alternating earth fault currents.

What is the rated current of the DS203NCC6AC300?

The RCBO has a rated current of 6 A and uses a C tripping characteristic.

What residual current sensitivity does this RCBO provide?

The DS203NCC6AC300 has a rated residual operating current of 300 mA and provides Type AC residual current protection.

What is the breaking capacity of the ABB DS203NCC6AC300?

The device has a rated short-circuit breaking capacity of 6 kA according to IEC/EN 61009.

How much DIN-rail space does the DS203NCC6AC300 require?

The DS203NCC6AC300 is a 3P+N device with a four-module width, providing combined residual current and overcurrent protection in a compact format.

Trusted ABB Circuit Protection

ABB DS203NC RCBOs provide compact combined residual current and overcurrent protection for modern three-phase electrical installations, helping engineers achieve dependable circuit protection while making efficient use of switchboard space.