2CSR255180R3137 ABB DS201K13A300 RCBO 1P+N Type A K13 300mA 6kA

2CSR255180R3137 ABB DS201K13A300 RCBO 1P+N Type A K13 300mA 6kA

ABB DS201K13A300 is a 13 A 1P+N Type A RCBO with K tripping characteristic, 300 mA residual-current sensitivity and 6 kA short-circuit capacity for combined overcurrent and residual-current protection.

SKU: 2CSR255180R3137Alt SKU: DS201K13A300MPN: 2CSR255180R3137
Price
List Price £270.59 ex VAT
Your Price (ex VAT) Save 35%
£175.88 35% OFF
You save £94.71 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £175.88
Trade pricing is personalised to your account

Manufacturer Lead Time

£175.88

Why Choose the ABB DS201K13A300 RCBO?

The ABB DS201K13A300 is a compact and reliable 1P+N residual current circuit breaker with overcurrent protection (RCBO) designed to protect single-phase electrical circuits against overloads, short circuits and residual earth fault currents. As part of the ABB DS201 series, it combines residual-current and overcurrent protection in a single DIN rail device for residential, commercial and industrial electrical installations.

This RCBO features a 13 A rated current, K tripping characteristic and Type A residual-current detection. Type A protection detects sinusoidal AC and pulsating DC residual currents, while the K characteristic is suited to circuits where connected equipment can produce higher starting currents.

With a rated residual operating current of 300 mA and a rated short-circuit capacity of 6 kA, the DS201K13A300 provides combined circuit and residual-current protection in a compact format. Its 1P+N configuration and DIN rail mounting support straightforward integration into electrical distribution boards and control panels.

Key Advantages

  • Combined overcurrent and residual-current protection in one RCBO.
  • 13 A rated current with K tripping characteristic.
  • Type A residual-current detection for sinusoidal AC and pulsating DC fault currents.
  • 300 mA rated residual operating current.
  • 6 kA rated short-circuit capacity.
  • Compact 1P+N design for DIN rail distribution boards.

Key Features

  • ABB DS201 RCBO series.
  • 13 A nominal current.
  • K characteristic overcurrent protection.
  • Type A residual-current protection.
  • 300 mA residual-current sensitivity.
  • 1P+N pole configuration.
  • 6 kA rated short-circuit capacity (Icn).
  • DIN rail mounting for distribution boards and control panels.

Combined Circuit and Residual-Current Protection

RCBOs combine the functions of a miniature circuit breaker and a residual current device in one unit. The ABB DS201K13A300 protects single-phase circuits against overload and short-circuit currents while monitoring for residual currents to earth, providing combined electrical protection within a compact distribution-board footprint.

The Type A residual-current characteristic allows the device to respond to sinusoidal AC and pulsating DC residual currents. Its K tripping characteristic provides overcurrent protection for suitable circuits containing equipment that can draw higher starting currents during normal operation.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial building electrical installations.
  • Industrial distribution and control panels.
  • Single-phase branch circuit protection.
  • Circuits supplying equipment with higher starting currents.
  • Installations requiring Type A residual-current detection.

Technical Specifications

Series DS201
ABB order code 2CSR255180R3137
Product group DS200 / DSH200 RCBO
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Rated current 13 A
Tripping characteristic K
Residual-current type Type A
Rated residual operating current 300 mA
Number of poles 1P+N
Rated short-circuit capacity (Icn) 6 kA
Mounting type DIN rail

Frequently Asked Questions

What is the ABB DS201K13A300 used for?

The DS201K13A300 is an RCBO used to protect single-phase electrical circuits against overloads, short circuits and residual earth fault currents.

What is the current rating of the DS201K13A300?

The ABB DS201K13A300 has a rated current of 13 A and uses a K tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The DS201K13A300 has a rated residual operating current of 300 mA and provides Type A residual-current detection.

What is the short-circuit capacity of the ABB DS201K13A300?

The device has a rated short-circuit capacity of 6 kA.

How is the DS201K13A300 installed?

The RCBO is designed for DIN rail mounting in electrical distribution boards and control panels.

Trusted ABB Circuit Protection

ABB DS201 RCBOs provide combined overcurrent and residual-current protection in a compact DIN rail format for residential, commercial and industrial electrical installations.