ABB DS204 AC-C50/0.03 is a four-pole 50 A Type AC RCBO with 30 mA residual-current sensitivity, C tripping characteristic and 6 kA short-circuit breaking capacity for combined earth-leakage and overcurrent protection.

SKU: 2CSR254001R1504Alt SKU: DS204ACC500.03MPN: 2CSR254001R1504
Price
List Price £484.36 ex VAT
Your Price (ex VAT) Save 35%
£314.83 35% OFF
You save £169.53 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £314.83
Trade pricing is personalised to your account

Manufacturer Lead Time

£314.83

Why Choose the ABB DS204 AC-C50/0.03 RCBO?

The ABB DS204 AC-C50/0.03 is a reliable four-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and AC residual earth-fault currents. As part of the ABB DS200 RCBO series, it combines residual-current and overcurrent protection in a single DIN-rail device for efficient electrical distribution and circuit protection.

This RCBO has a 50 A rated current, C tripping characteristic and 30 mA rated residual operating current. Its Type AC residual-current characteristic is intended for detecting sinusoidal alternating residual currents, while the integrated thermal-magnetic protection provides dependable protection against overload and short-circuit conditions.

With a 6 kA rated short-circuit breaking capacity and four-pole configuration, the DS204 AC-C50/0.03 is suitable for three-phase electrical distribution circuits requiring coordinated protection of all poles. The 50 A and 63 A DS204 versions also incorporate additional terminals for remote tripping, supporting enhanced control and protection arrangements.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 50 A rated current for higher-current distribution circuits.
  • 30 mA residual operating current for sensitive earth-leakage protection.
  • Type AC residual-current detection for sinusoidal alternating residual currents.
  • C tripping characteristic suitable for circuits with moderate inrush currents.
  • 6 kA short-circuit breaking capacity.
  • Four-pole configuration for three-phase circuit protection.
  • Additional terminals provided for remote tripping on the 50 A version.

Key Features

  • ABB DS200 RCBO series.
  • 4-pole configuration.
  • 50 A rated current.
  • 30 mA rated residual operating current.
  • Type AC residual-current characteristic.
  • C curve overcurrent characteristic.
  • 6 kA rated short-circuit breaking capacity.
  • Thermal-magnetic overcurrent protection.
  • DIN-rail mounting for distribution boards and electrical panels.
  • Additional terminals for remote tripping.

Combined Residual-Current and Overcurrent Protection

RCBOs combine the functions normally provided by a residual current device and a miniature circuit breaker. This enables a single protective device to respond to earth-leakage faults as well as overload and short-circuit conditions, helping simplify distribution-board design while providing comprehensive circuit protection.

The ABB DS200 series is designed for electrical distribution applications where dependable protection and compact DIN-rail installation are required. The DS204 AC-C50/0.03 provides four-pole switching and protection, making it particularly suitable for three-phase circuits where residual-current and overcurrent protection must be integrated into one device.

Typical Applications

  • Three-phase electrical distribution boards.
  • Commercial and industrial electrical installations.
  • Machinery and automation distribution circuits.
  • Building electrical systems.
  • Circuits requiring combined earth-leakage and overcurrent protection.
  • DIN-rail control and distribution panels.

Technical Specifications

Series DS200 / DSH200 RCBO
ABB order code 2CSR254001R1504
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 4
Rated current 50 A
Rated residual operating current 30 mA
Residual-current type AC
Tripping characteristic C
Rated short-circuit breaking capacity 6 kA
Frequency 50 / 60 Hz
Mounting type DIN rail
Unit weight approx. 0.825 kg

Frequently Asked Questions

What is the ABB DS204 AC-C50/0.03 used for?

It is a four-pole RCBO used to protect electrical circuits against overloads, short circuits and AC residual earth-fault currents.

What is the rated current of the DS204 AC-C50/0.03?

The RCBO has a rated current of 50 A with a C tripping characteristic.

What residual current sensitivity does this RCBO provide?

The DS204 AC-C50/0.03 has a rated residual operating current of 30 mA and uses a Type AC residual-current characteristic.

What is the breaking capacity of the ABB DS204 AC-C50/0.03?

The device has a rated short-circuit breaking capacity of 6 kA.

How many poles does the DS204 AC-C50/0.03 have?

The DS204 AC-C50/0.03 is a four-pole RCBO designed for multi-pole electrical distribution and three-phase circuit protection.

Trusted ABB Circuit Protection

ABB DS200 RCBOs provide integrated residual-current and overcurrent protection for electrical distribution systems, combining dependable circuit protection with convenient DIN-rail installation in commercial and industrial applications.