2CSR253001R1065 ABB DS203 AC-B6/0.03 RCBO 3P Type AC 6A 30mA 6kA

2CSR253001R1065 ABB DS203 AC-B6/0.03 RCBO 3P Type AC 6A 30mA 6kA

ABB DS203 AC-B6/0.03 is a three-pole Type AC RCBO with a 6 A rated current, 30 mA residual-current sensitivity, B tripping characteristic and 6 kA short-circuit breaking capacity for suitable three-phase commercial and industrial circuit protection.

SKU: 2CSR253001R1065Alt SKU: DS203ACB60.03MPN: 2CSR253001R1065
Price
List Price £310.23 ex VAT
Your Price (ex VAT) Save 35%
£201.65 35% OFF
You save £108.58 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £201.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£201.65

Why Choose the ABB DS203 AC-B6/0.03 RCBO?

The ABB DS203 AC-B6/0.03 is a three-pole Type AC residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and residual earth fault currents. As part of the ABB DS200 / DSH200 RCBO range, it integrates residual-current and overcurrent protection in a single DIN-rail device for three-phase commercial and industrial electrical distribution systems.

With a rated current of 6 A, a rated residual operating current of 30 mA and a 6 kA rated short-circuit breaking capacity, the DS203 AC-B6/0.03 provides coordinated protection for lower-current three-phase circuits. Its Type AC residual-current characteristic is designed to detect sinusoidal alternating residual currents, while the three-pole configuration provides protection across all three phases.

The B tripping characteristic is suited to circuits with relatively low inrush currents, making this RCBO appropriate for resistive loads, general distribution and control circuits where high starting currents are not normally expected. Its compact modular construction enables straightforward installation within suitable electrical distribution boards and control panels.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one device.
  • 6 A rated current suitable for lower-current three-phase circuits.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type AC residual-current detection for sinusoidal alternating residual currents.
  • 6 kA rated short-circuit breaking capacity.
  • B tripping characteristic suitable for circuits with relatively low inrush currents.
  • Three-pole configuration for three-phase electrical systems.
  • DIN-rail format for straightforward integration into distribution boards and control panels.

Key Features

  • ABB DS200 series RCBO.
  • 6 A rated current.
  • 30 mA rated residual operating current.
  • Type AC residual-current characteristic.
  • B overcurrent tripping characteristic.
  • 3-pole configuration.
  • 6 kA rated short-circuit breaking capacity.
  • Combined residual-current and thermal-magnetic overcurrent protection.
  • Protection against sinusoidal AC residual earth fault currents.
  • Integrated test function for verification of residual-current operation.
  • DIN-rail mounting for modular electrical distribution systems.
  • Designed for suitable commercial and industrial three-phase circuits.

Reliable Three-Phase Circuit Protection

An RCBO combines the protective functions of an overcurrent circuit breaker and a residual current device in a single assembly. The ABB DS203 AC-B6/0.03 therefore protects connected three-phase circuits against overload and short-circuit currents while monitoring for sinusoidal AC residual earth fault currents.

The B characteristic is designed for circuits with comparatively low inrush currents, making this model suitable for appropriate resistive loads, control circuits and general electrical distribution applications. Together with its 30 mA Type AC residual-current protection and three-pole construction, the DS203 AC-B6/0.03 provides an integrated protection solution for suitable three-phase installations.

Typical Applications

  • Three-phase commercial electrical distribution systems.
  • Industrial electrical distribution boards.
  • Three-phase control and auxiliary circuits.
  • Industrial control panels and switchboards.
  • Resistive loads and circuits with relatively low inrush currents.
  • DIN-rail installations requiring combined 6 A three-pole RCBO protection.

Technical Specifications

Series DS200 / DSH200 RCBO
ABB order code 2CSR253001R1065
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3
Rated current 6 A
Rated residual current 30 mA
Residual-current type Type AC
Tripping characteristic B
Rated short-circuit breaking capacity 6 kA
Supply system Three-phase AC
Overcurrent protection Thermal-magnetic
Mounting type DIN rail
Application Commercial and industrial electrical distribution

Frequently Asked Questions

What is the ABB DS203 AC-B6/0.03 used for?

The ABB DS203 AC-B6/0.03 provides combined protection against overloads, short circuits and sinusoidal AC residual earth fault currents in suitable three-phase commercial and industrial electrical circuits.

What is the current rating of the DS203 AC-B6/0.03?

The RCBO has a rated current of 6 A and a rated residual operating current of 30 mA.

What does the B characteristic mean?

The B tripping characteristic is designed for circuits with relatively low inrush currents and is suitable for appropriate resistive loads, general distribution and control circuits.

What residual-current type is the DS203 AC-B6/0.03?

It is a Type AC RCBO, designed to respond to sinusoidal alternating residual currents.

What is the breaking capacity of the ABB DS203 AC-B6/0.03?

The DS203 AC-B6/0.03 has a 6 kA rated short-circuit breaking capacity for suitable commercial and industrial circuit protection applications.

Trusted ABB Circuit Protection

ABB DS200 series RCBOs combine residual-current and overcurrent protection for electrical distribution systems, with the DS203 AC-B6/0.03 providing a 6 A rating, Type AC residual-current detection, B tripping characteristic and three-pole construction for suitable commercial and industrial three-phase circuits.