ABB DS202 A-K40/0.03 is a two-pole Type A RCBO with a 40 A rated current, 30 mA residual-current sensitivity, K tripping characteristic and 6 kA rated short-circuit breaking capacity for commercial and industrial circuit protection.
£285.12
The ABB DS202 A-K40/0.03 is a two-pole Type A residual current circuit breaker with overcurrent protection (RCBO) designed to protect electrical circuits against overloads, short circuits and residual earth fault currents. As part of the ABB DS200 / DSH200 RCBO range, it combines residual-current and overcurrent protection in a single DIN-rail device for commercial and industrial electrical distribution systems.
With a rated current of 40 A, a rated residual operating current of 30 mA and a 6 kA rated short-circuit breaking capacity according to IEC/EN 61009-1, the DS202 A-K40/0.03 provides comprehensive circuit protection. Its Type A residual-current characteristic detects sinusoidal AC and pulsating DC residual currents, making it suitable for circuits supplying a wide variety of modern electrical equipment.
The K tripping characteristic is particularly suited to circuits containing motors, transformers and auxiliary equipment where temporary current peaks can occur during start-up. The K characteristic is designed to tolerate current peaks of up to approximately 10 times the rated current, helping reduce unwanted tripping while maintaining effective protection against sustained overcurrents.
An RCBO combines the protective functions of a miniature circuit breaker and a residual current device in a single assembly. The ABB DS202 A-K40/0.03 therefore protects the connected circuit against overload and short-circuit currents while monitoring for potentially dangerous residual earth fault currents.
The K characteristic makes this model particularly useful where equipment can draw significant temporary starting currents. Motors, transformers and auxiliary circuits can produce current peaks during normal start-up, and the DS202 A-K40/0.03 is designed to accommodate these conditions while continuing to provide sensitive thermal protection for cables, circuits and connected equipment.
| Series | DS200 / DSH200 RCBO |
|---|---|
| ABB order code | 2CSR252101R1407 |
| EAN | 8012542930907 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Number of poles | 2 |
| Number of protected poles | 2 |
| Rated current | 40 A |
| Rated residual current | 30 mA |
| Residual-current type | Type A |
| Tripping characteristic | K |
| Rated short-circuit breaking capacity (Icn) | 6 kA |
| Ultimate short-circuit breaking capacity (Icu) | 10 kA |
| Rated voltage | 230 V AC |
| Rated frequency | 50 / 60 Hz |
| Operating mechanism | Thermal-magnetic |
| Standards | IEC/EN 61009-1, IEC/EN 60947-2 |
| Mounting type | DIN rail |
| Width | approx. 70 mm |
| Height | approx. 93 mm |
| Depth | approx. 69 mm |
| Width in modular units | 4 modules |
| Weight | approx. 0.475 kg |
The ABB DS202 A-K40/0.03 provides combined protection against overloads, short circuits and residual earth fault currents, particularly in commercial and industrial circuits containing equipment with elevated starting currents.
The RCBO has a rated current of 40 A and a rated residual operating current of 30 mA.
The K tripping characteristic is designed for circuits containing equipment such as motors and transformers that can produce high temporary starting currents, helping reduce unwanted tripping while maintaining effective overcurrent protection.
It is a Type A RCBO, designed to respond to sinusoidal AC residual currents and pulsating DC residual currents.
The DS202 A-K40/0.03 has a 6 kA rated short-circuit breaking capacity according to IEC/EN 61009-1 and an ultimate short-circuit breaking capacity of 10 kA according to IEC/EN 60947-2.
ABB DS200 series RCBOs provide integrated residual-current and overcurrent protection for electrical distribution systems, with the DS202 A-K40/0.03 combining Type A residual-current detection, a K tripping characteristic and two-pole protection for demanding commercial and industrial circuits.