2CSR252001R1404 ABB DS202 AC-C40/0.03 RCBO 2P Type AC 30mA C40 6kA

2CSR252001R1404 ABB DS202 AC-C40/0.03 RCBO 2P Type AC 30mA C40 6kA

ABB DS202 AC-C40/0.03 is a two-pole Type AC RCBO rated at 40 A and 30 mA with a C-curve characteristic and 6 kA short-circuit breaking capacity for combined residual-current, overload and short-circuit protection.

SKU: 2CSR252001R1404Alt SKU: DS202ACC400.03MPN: 2CSR252001R1404
Price
List Price £253.94 ex VAT
Your Price (ex VAT) Save 35%
£165.06 35% OFF
You save £88.88 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £165.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£165.06

Why Choose the ABB DS202 AC-C40/0.03 RCBO?

The ABB DS202 AC-C40/0.03 is a two-pole Type AC residual current circuit breaker with overcurrent protection (RCBO) designed to combine residual-current, overload and short-circuit protection within a single modular device. Part of ABB’s DS200 series 6000, it provides dedicated circuit protection for commercial and industrial electrical distribution systems.

With a rated current of 40 A, a C-curve tripping characteristic and a rated residual operating current of 30 mA, the DS202 AC-C40/0.03 protects against overload and short-circuit currents while responding to sinusoidal alternating earth-fault currents. Its 30 mA sensitivity provides protection against indirect contact and additional protection against direct contact.

The DS202 AC-C40/0.03 operates at 230 V AC and has a rated short-circuit breaking capacity of 6 kA under IEC/EN 61009 requirements. Its two-pole configuration, C-curve overcurrent characteristic and integrated Type AC residual-current protection make it a practical solution for final circuits requiring individual fault isolation and comprehensive electrical protection.

Key Advantages

  • Combined RCBO protection against residual current, overload and short circuit within one device.
  • 30 mA residual-current sensitivity provides additional protection against electric shock.
  • 40 A rated current for suitable higher-current final circuits.
  • C-curve characteristic accommodates moderate starting and inrush currents while providing effective overcurrent protection.
  • Type AC residual-current detection responds to sinusoidal alternating earth-fault currents.
  • 6 kA rated short-circuit breaking capacity under IEC/EN 61009 requirements.
  • Two-pole configuration provides protection and isolation for both poles.

Key Features

  • ABB DS200 series 6000 RCBO.
  • 40 A rated current.
  • 30 mA rated residual operating current (IΔn).
  • C tripping characteristic.
  • Type AC residual-current characteristic.
  • Two-pole configuration.
  • 230 V AC rated voltage.
  • 6 kA rated short-circuit breaking capacity (Icn).
  • Protection against overload and short-circuit currents.
  • Protection against sinusoidal alternating earth-fault currents.
  • Protection against indirect contact and additional protection against direct contact.
  • Designed for commercial and industrial applications.

Combined Residual-Current and Overcurrent Protection

An RCBO combines the functions of residual-current protection and overcurrent protection within a single protective device. The ABB DS202 AC-C40/0.03 protects its circuit against sinusoidal alternating earth-fault currents as well as overload and short-circuit conditions, enabling dedicated circuit protection without requiring separate RCCB and MCB devices to perform these functions.

Its Type AC characteristic is designed for sinusoidal alternating residual currents, while the C-curve 40 A characteristic is suitable for circuits where moderate starting or inrush currents may occur. Combined with 30 mA residual-current sensitivity and a 6 kA rated short-circuit breaking capacity, the DS202 AC-C40/0.03 provides comprehensive protection for suitable commercial and industrial circuits.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial electrical distribution systems.
  • Final circuits requiring 40 A C-curve overcurrent protection.
  • Circuits requiring 30 mA additional residual-current protection.
  • Equipment circuits with moderate normal starting or inrush currents.
  • Electrical installations requiring dedicated two-pole RCBO protection and individual fault isolation.

Technical Specifications

Series DS200 series 6000
Product group DS200 / DSH200 RCBO
ABB order code 2CSR252001R1404
EAN 8012542870203
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2P
Rated current (In) 40 A
Rated residual current (IΔn) 30 mA
Residual-current type Type AC
Tripping characteristic C curve
Rated voltage 230 V AC
Rated operational voltage 230 V AC
Rated short-circuit breaking capacity (Icn) 6 kA
Tripping mechanism Thermal magnetic
Width 70 mm
Depth 69 mm
Height 93 mm
Mounting type DIN rail
Weight approx. 0.44 kg
Standards IEC/EN 61009-1, IEC/EN 61009-2-1 and IEC/EN 60947-2
Applications Commercial and industrial

Frequently Asked Questions

What is the ABB DS202 AC-C40/0.03 used for?

The ABB DS202 AC-C40/0.03 is an RCBO that combines overload and short-circuit protection with 30 mA Type AC residual-current protection for commercial and industrial electrical circuits.

What are the current and residual-current ratings?

The DS202 AC-C40/0.03 has a rated current of 40 A and a rated residual operating current of 30 mA.

What does the C characteristic mean?

The C-curve tripping characteristic defines the magnetic overcurrent response of the RCBO and is commonly used for circuits where moderate starting or inrush currents can occur during normal operation.

What is the breaking capacity of the ABB DS202 AC-C40/0.03?

The DS202 AC-C40/0.03 has a rated short-circuit breaking capacity of 6 kA under IEC/EN 61009 requirements.

What is the ABB order code for the DS202 AC-C40/0.03?

The ABB order code for the DS202 AC-C40/0.03 is 2CSR252001R1404.

Trusted ABB Combined Circuit Protection

ABB DS200 RCBOs combine residual-current, overload and short-circuit protection within a single modular device, providing dedicated circuit protection and effective fault isolation for commercial and industrial electrical distribution systems.