2CSR252001R1105 ABB DS202 AC-B10/0.03 RCBO 2 Pole 10 A 30 mA 6 kA

2CSR252001R1105 ABB DS202 AC-B10/0.03 RCBO 2 Pole 10 A 30 mA 6 kA

ABB DS202 AC-B10/0.03 is a two-pole 10 A Type B Type AC RCBO with 30 mA residual-current sensitivity and 6 kA short-circuit capacity for combined residual-current and overcurrent protection.

SKU: 2CSR252001R1105Alt SKU: DS202ACB100.03MPN: 2CSR252001R1105
Price
List Price £230.48 ex VAT
Your Price (ex VAT) Save 35%
£149.81 35% OFF
You save £80.67 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £149.81
Trade pricing is personalised to your account

Manufacturer Lead Time

£149.81

Why Choose the ABB DS202 AC-B10/0.03 RCBO?

The ABB DS202 AC-B10/0.03 is a compact and reliable two-pole residual current circuit breaker with overcurrent protection (RCBO) designed to protect electrical circuits against overloads, short circuits and AC residual currents. As part of the ABB DS200 RCBO series, it combines miniature circuit breaker and residual-current protection functions in a single DIN-rail device.

This RCBO combines a Type B overcurrent tripping characteristic with Type AC residual-current detection, making it suitable for circuits with relatively low inrush currents. By providing both overcurrent and earth-leakage protection at individual circuit level, the DS202 can simplify distribution-board design and help isolate faults to the affected circuit.

With a rated current of 10 A, a rated residual operating current of 30 mA and a rated short-circuit capacity of 6 kA, the DS202 AC-B10/0.03 provides comprehensive protection for suitable final circuits in residential, commercial and similar installations. Its two-pole configuration provides switching of both conductors.

Key Advantages

  • Combined overload, short-circuit and residual-current protection in one device.
  • 10 A rated current for lower-current final circuits.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type AC residual-current characteristic for sinusoidal AC residual currents.
  • Type B tripping characteristic suitable for circuits with low inrush currents.
  • 6 kA short-circuit breaking capacity for dependable fault protection.

Key Features

  • ABB DS200 RCBO series.
  • 10 A rated current.
  • 30 mA rated residual operating current.
  • B-curve overcurrent characteristic.
  • Type AC residual-current characteristic.
  • Two-pole configuration.
  • 6 kA rated short-circuit capacity.
  • Compact DIN-rail format combining residual-current and overcurrent protection.

Combined Residual-Current and Overcurrent Protection

An RCBO combines the functions of a miniature circuit breaker and a residual current device. It disconnects the protected circuit when an overload or short circuit occurs and also operates when residual current to earth exceeds its specified threshold, providing multiple forms of electrical protection within one modular device.

The ABB DS202 AC-B10/0.03 uses a B-curve overcurrent characteristic and Type AC residual-current detection. Its 30 mA residual-current sensitivity makes it suitable for appropriate final circuits requiring additional protection, while individual RCBO protection helps prevent a fault on one circuit from unnecessarily disconnecting other independently protected circuits.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial and similar electrical installations.
  • Lighting circuits with low starting currents.
  • General final circuits within the device rating.
  • Circuits requiring combined overcurrent and residual-current protection.
  • DIN-rail distribution systems requiring individual circuit protection.

Technical Specifications

Series DS200
ABB order code 2CSR252001R1105
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Rated current 10 A
Rated residual operating current 30 mA
Residual-current type Type AC
Tripping characteristic Type B
Poles 2
Rated short-circuit capacity 6 kA
Mounting type DIN rail

Frequently Asked Questions

What is the ABB DS202 AC-B10/0.03 used for?

It protects electrical circuits against overloads, short circuits and AC residual currents using a single two-pole RCBO.

What is the rated current of the DS202 AC-B10/0.03?

The RCBO has a rated current of 10 A with a Type B overcurrent tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The DS202 AC-B10/0.03 has a rated residual operating current of 30 mA.

What is the short-circuit capacity of the DS202 AC-B10/0.03?

The RCBO has a rated short-circuit capacity of 6 kA.

What residual-current type is the DS202 AC-B10/0.03?

It is a Type AC RCBO, designed to respond to sinusoidal alternating residual currents.

Reliable Circuit Protection from ABB

ABB DS200 RCBOs combine residual-current and overcurrent protection in compact modular devices, providing dependable individual circuit protection for residential, commercial and similar electrical distribution systems.