ABB F-ARI4Test A-40/0.03 is a 40 A 30 mA Type A 3P+N residual current circuit breaker with automatic testing, insulation checking and automatic reclosing.
£809.84
The ABB F-ARI4Test A-40/0.03 is an advanced Type A residual current circuit breaker (RCCB) with automatic testing and automatic reclosing designed to provide reliable residual-current protection while supporting continuity of electrical service. As part of the ABB F-ARI Test series, it combines automatic periodic testing with automatic reclosing following an insulation-system check.
The F-ARI Test system automatically tests the RCCB without disconnecting voltage from the protected installation, helping reduce manual maintenance while keeping connected equipment energised. If an earth fault causes the RCCB to trip, the automatic reclosing function checks the insulation condition before restoring the supply, helping prevent reconnection while a permanent fault remains present.
With a rated current of 40 A, a rated residual operating current of 30 mA and a 3P+N four-pole configuration, the F-ARI4Test A-40/0.03 provides Type A residual-current protection for three-phase circuits with neutral. Its 7-module DIN-rail format makes it suitable for commercial, industrial and infrastructure distribution boards where dependable protection and service continuity are important.
Residual current circuit breakers monitor electrical circuits for leakage current to earth and disconnect the supply when the residual current reaches the specified operating threshold. Type A RCCBs detect sinusoidal AC and pulsating DC residual currents, making them suitable for many modern electrical installations containing electronic equipment.
The ABB F-ARI Test series extends conventional RCCB protection with automatic testing and reclosing. Periodic testing can be performed without interrupting the protected circuit, while the reclosing process checks the insulation condition following an earth-fault trip before restoring power, helping improve system availability without compromising residual-current protection.
| Series | F-ARI Test |
|---|---|
| ABB order code | 2CSF304131R1400 |
| Product type | RCCB with automatic test and automatic reclosing |
| Residual-current type | Type A |
| Rated current | 40 A |
| Rated residual operating current | 30 mA |
| Poles | 3P+N / 4 pole |
| Automatic test | Yes, without supply interruption |
| Automatic reclosing | Yes |
| Insulation check before reclosing | Yes |
| Module width | 7 modules |
| Mounting type | DIN rail |
| Dimensions (H × W × D) | approx. 106 × 124.8 × 73.5 mm |
| Weight | approx. 0.9 kg |
| EAN | 8012542290056 |
It provides Type A residual-current protection for three-phase circuits with neutral while adding automatic testing and automatic reclosing functionality.
The RCCB has a rated current of 40 A.
The F-ARI4Test A-40/0.03 has a rated residual operating current of 30 mA.
Yes. The F-ARI incorporates automatic reclosing and checks the insulation condition of the system before attempting to restore the electrical supply.
No. The F-ARI Test system performs its automatic RCCB test without disconnecting voltage from the protected installation, helping maintain continuity of service.
ABB F-ARI Test RCCBs combine automatic testing, insulation fault checking and automatic reclosing to support dependable residual-current protection and improved continuity of service in modern electrical installations.