2CSF304130R1630 ABB F-ATI4Test A-63/0.03 RCCB 4 Pole 63 A 30 mA Auto Test

2CSF304130R1630 ABB F-ATI4Test A-63/0.03 RCCB 4 Pole 63 A 30 mA Auto Test

ABB F-ATI4Test A-63/0.03 is a 63 A 30 mA Type A 3P+N residual current circuit breaker with automatic testing without interruption of the electrical supply.

SKU: 2CSF304130R1630Alt SKU: FATI4TESTA630.03MPN: 2CSF304130R1630
Price
List Price £1,175.79 ex VAT
Your Price (ex VAT) Save 35%
£764.26 35% OFF
You save £411.53 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £764.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£764.26

Why Choose the ABB F-ATI4Test A-63/0.03 RCCB?

The ABB F-ATI4Test A-63/0.03 is a highly reliable Type A residual current circuit breaker (RCCB) with automatic testing designed to provide residual-current protection while carrying out periodic functional tests without interrupting the electrical supply. As part of the ABB F-ATI Test series, it combines dependable earth-leakage protection with an automatic test function for installations where continuity of supply is important.

The F-ATI Test system automatically checks the RCCB at regular intervals without disconnecting downstream loads, reducing the need for manual testing while helping ensure that the protective device remains operational. This makes it particularly suitable for commercial, industrial and infrastructure installations where unnecessary interruption of electrical services should be minimised.

With a rated current of 63 A, a rated residual operating current of 30 mA and a 3P+N four-pole configuration, the F-ATI4Test A-63/0.03 provides Type A residual-current detection for three-phase circuits with neutral. The device occupies 7 modules and is designed for DIN-rail installation in electrical distribution boards.

Key Advantages

  • Integrated automatic RCCB test function without interruption of the power supply.
  • 63 A rated current for three-phase distribution applications.
  • 30 mA residual operating current for sensitive residual-current protection.
  • Type A detection for AC and pulsating DC residual currents.
  • 3P+N four-pole configuration for three-phase circuits with neutral.
  • Automatic testing helps reduce the requirement for routine manual functional testing.

Key Features

  • ABB F-ATI Test automatic-test RCCB series.
  • 63 A rated current.
  • 30 mA rated residual operating current.
  • Type A residual-current characteristic.
  • 3P+N / four-pole configuration.
  • Automatic periodic functional testing without disconnecting the protected circuit.
  • Short-time delayed residual-current operation.
  • 7-module DIN-rail format.

Automatic Residual-Current Protection

Residual current circuit breakers disconnect a circuit when potentially hazardous leakage current to earth exceeds the device's operating threshold. Type A RCCBs detect sinusoidal AC residual currents as well as pulsating DC residual currents, making them suitable for many modern electrical loads containing electronic components.

The ABB F-ATI Test series adds automatic functional testing to conventional residual-current protection. The test is performed without interrupting the electrical supply, helping maintain protection while avoiding unnecessary downtime in installations containing equipment that should remain continuously energised.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • Three-phase circuits requiring residual-current protection.
  • Installations where continuity of electrical supply is important.
  • Building automation and electrical infrastructure systems.
  • Unattended or remotely located electrical installations.
  • Circuits where automatic periodic RCCB testing can reduce routine maintenance requirements.

Technical Specifications

Series F-ATI Test
ABB order code 2CSF304130R1630
Product type RCCB with automatic test
Residual-current type Type A
Rated current 63 A
Rated residual operating current 30 mA
Poles 3P+N / 4 pole
Automatic test Yes, without supply interruption
Test interval Every 28 days
Tripping characteristic Short-time delayed
Module width 7 modules
Mounting type DIN rail
Weight approx. 0.9 kg
EAN 8012542289357

Frequently Asked Questions

What is the ABB F-ATI4Test A-63/0.03 used for?

It provides Type A residual-current protection for three-phase circuits with neutral while automatically testing its protective function without interrupting the electrical supply.

What is the rated current of the F-ATI4Test A-63/0.03?

The RCCB has a rated current of 63 A.

What residual operating current does this RCCB provide?

The F-ATI4Test A-63/0.03 has a rated residual operating current of 30 mA.

Does the ABB F-ATI4Test interrupt the supply during its automatic test?

No. The F-ATI Test system is designed to perform its automatic functional test without interrupting the electrical supply to downstream equipment.

How many poles does the F-ATI4Test A-63/0.03 have?

The device has a 3P+N four-pole configuration for three-phase electrical systems with neutral.

Trusted Residual-Current Protection from ABB

ABB F-ATI Test RCCBs combine established residual-current protection technology with automatic testing, helping electrical installations maintain protective functionality while minimising disruption to connected equipment.