ABB F204 B S-40/0.3 is a four-pole selective Type B residual current circuit breaker rated at 40 A with 300 mA residual-current sensitivity for three-phase electrical installations requiring all-current-sensitive earth-fault protection.
£751.84
The ABB F204 B S-40/0.3 is a selective four-pole Type B residual current circuit breaker (RCCB) designed to protect people and electrical installations against residual currents to earth. Part of the established ABB F200 RCCB series, it provides all-current-sensitive protection for installations where sinusoidal AC, pulsating DC and smooth DC residual currents can occur.
This RCCB is particularly suited to modern electrical systems containing non-linear loads and power electronic equipment such as frequency converters. Its Type B characteristic detects residual currents over a frequency range of 0–2 kHz, while the selective S-type operating characteristic provides time-delayed discrimination for coordinated residual-current protection in distribution systems.
With a rated current of 40 A and a rated residual operating current of 300 mA, the F204 B S-40/0.3 is suitable for three-phase installations where selective earth-fault and fire protection is required. The four-pole device has a rated voltage of 400 V AC, a surge-current withstand capability of 5 kA and a compact four-module DIN-rail format for installation in distribution boards and control panels.
Type B RCCBs are designed for circuits where electronic equipment can generate residual-current waveforms that conventional Type AC or Type A devices may not fully detect. The ABB F204 B S-40/0.3 provides all-current-sensitive protection against sinusoidal AC, pulsating and smooth DC residual currents and detects relevant residual currents across a frequency range of 0–2 kHz.
The selective S-type characteristic is designed for coordinated residual-current protection where discrimination between upstream and downstream devices is required. With a 300 mA residual-current rating and 5 kA surge-current withstand capability, the F204 B S-40/0.3 is well suited to upstream protection in commercial and industrial distribution systems containing frequency converters and other power electronic loads.
| Series | F200 |
|---|---|
| Product group | F200 / FH200 RCCB |
| ABB order code | 2CSF204868R3400 |
| EAN | 8012542342557 |
| Product type | Residual current circuit breaker (RCCB) |
| Residual-current type | Type B |
| Selective protection | Yes, S type |
| Number of poles | 4P |
| Rated current (In) | 40 A |
| Rated residual current (IΔn) | 300 mA |
| Rated voltage | 400 V AC |
| Rated insulation voltage (Ui) | 440 V |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Residual-current detection frequency range | 0–2 kHz |
| Surge-current withstand | 5 kA |
| Protection rating | IP20 |
| Pollution degree | 2 |
| Width | 4 modules |
| Installation depth | 69 mm |
| Mounting type | DIN rail |
| Operating ambient temperature | -25–65 °C |
| Weight | approx. 0.38 kg |
The ABB F204 B S-40/0.3 is a four-pole selective Type B RCCB used for residual-current protection in three-phase electrical installations, including systems containing frequency converters and other equipment capable of producing smooth DC residual currents.
The RCCB has a rated current of 40 A.
The F204 B S-40/0.3 has a rated residual operating current (IΔn) of 300 mA, making it suitable for earth-fault and fire protection applications where the installation design requires this sensitivity.
Type B indicates all-current-sensitive residual-current detection, including smooth DC residual currents, while S identifies the selective characteristic designed to support discrimination with downstream residual-current protection devices.
The ABB order code for the F204 B S-40/0.3 is 2CSF204868R3400.