Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB F204 B-63/0.5 is a four-pole Type B residual current circuit breaker rated at 63 A with 500 mA residual-current sensitivity for electrical installations requiring detection of AC, pulsating DC and smooth DC residual currents.
£888.58
The ABB F204 B-63/0.5 is a high-performance four-pole Type B residual current circuit breaker (RCCB) designed to protect electrical installations against earth fault and residual currents. Part of the proven ABB F200 RCCB series, this device is particularly suitable for installations where smooth DC residual currents may occur alongside AC and pulsating DC fault currents.
With a rated current of 63 A and rated residual operating current of 500 mA, the F204 B-63/0.5 provides dependable residual-current protection for three-phase electrical systems. Its Type B detection characteristics make it suitable for modern installations containing power electronic equipment that can generate residual-current waveforms which conventional AC or Type A RCCBs may not detect.
The ABB order code 2CSF204592R4630 identifies this four-pole device within the F200 range. Designed for DIN-rail installation, it has a rated voltage of 230/400 V AC, rated insulation voltage of 500 V and rated impulse withstand voltage of 4 kV. It complies with relevant RCCB standards including IEC/EN 61008-1, IEC/EN 61008-2-1 and EN 62423.
Type B RCCBs are designed for applications where electrical loads can produce residual currents containing AC, pulsating DC and smooth DC components. This makes the ABB F204 B-63/0.5 particularly useful in installations incorporating power electronics, converters and other equipment where more complex residual-current waveforms can occur.
The F204 B-63/0.5 provides residual-current protection without an integrated overcurrent protection function. Appropriate upstream protection against overloads and short circuits should therefore be provided as required by the electrical installation design. Its modular DIN-rail construction allows convenient installation alongside other ABB System pro M compact devices in electrical distribution boards and industrial control systems.
| Series | F200 |
|---|---|
| ABB order code | 2CSF204592R4630 |
| Product type | Residual current circuit breaker (RCCB) |
| Residual-current type | Type B |
| Number of poles | 4P |
| Rated current (In) | 63 A |
| Rated residual current (IΔn) | 500 mA |
| Rated voltage | 230/400 V AC |
| Rated insulation voltage (Ui) | 500 V |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Mounting type | DIN rail |
| Standards | IEC/EN 61008-1, IEC/EN 61008-2-1, EN 62423 |
| Weight | approx. 0.38 kg |
The ABB F204 B-63/0.5 is a four-pole Type B RCCB used to provide residual-current protection in electrical installations, including applications where smooth DC earth fault currents may occur.
The RCCB has a rated current of 63 A.
The F204 B-63/0.5 has a rated residual operating current (IΔn) of 500 mA.
Type B indicates that the RCCB is designed for residual-current waveforms that can include AC, pulsating DC and smooth DC components, making it suitable for installations containing certain power electronic equipment.
The ABB order code for this device is 2CSF204592R4630.
ABB F200 residual current circuit breakers are designed for dependable protection of people and electrical installations against earth fault currents, with Type B models providing additional capability for applications where smooth DC residual currents may occur.