2CSB803001R1630 ABB DDA803 AC-63/0.03 RCD Block 3P Type AC 63A 30mA

2CSB803001R1630 ABB DDA803 AC-63/0.03 RCD Block 3P Type AC 63A 30mA

ABB DDA803 AC-63/0.03 is a 3-pole Type AC residual current device block rated at 63 A with 30 mA residual operating current for adding residual-current protection to compatible ABB S800 circuit-breaker assemblies.

SKU: 2CSB803001R1630Alt SKU: DDA803AC630.03MPN: 2CSB803001R1630
Price
List Price £517.42 ex VAT
Your Price (ex VAT) Save 35%
£336.32 35% OFF
You save £181.10 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £336.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£336.32

Why Choose the ABB DDA803 AC-63/0.03 Residual Current Device?

The ABB DDA803 AC-63/0.03 is a 3-pole residual current device (RCD) block designed to provide residual-current protection when combined with a compatible ABB S800 series miniature circuit breaker. It provides a modular solution for adding earth-leakage protection to three-pole low-voltage electrical distribution circuits.

Featuring Type AC residual-current detection, the DDA803 AC-63/0.03 is designed to detect sinusoidal alternating residual currents. Its rated residual operating current of 30 mA provides sensitive residual-current protection for applications requiring this operating threshold.

With a rated current of 63 A and a 3-pole configuration, the DDA803 AC-63/0.03 is suitable for compatible three-pole ABB S800 circuit-breaker assemblies. Its modular construction supports integration into professional electrical distribution boards and control panels requiring combined overcurrent and residual-current protection.

Key Advantages

  • 30 mA rated residual operating current for sensitive residual-current protection.
  • 63 A rated current for compatible distribution circuits.
  • 3-pole configuration for three-pole circuit-breaker assemblies.
  • Type AC detection for sinusoidal alternating residual currents.
  • Designed for combination with compatible ABB S800 series MCBs.
  • Modular construction supports integration into distribution-board assemblies.

Key Features

  • ABB DDA800 series residual current device block.
  • 63 A rated current.
  • 30 mA rated residual operating current.
  • 3-pole construction.
  • Type AC residual-current characteristic.
  • Detection of sinusoidal alternating residual currents.
  • Provides residual-current protection when assembled with a compatible circuit breaker.
  • Designed for low-voltage electrical distribution applications.

Type AC Residual-Current Protection for S800 Circuit Breaker Assemblies

Residual current devices detect current imbalance caused by leakage from the protected circuit towards earth. When the residual current reaches the device operating threshold, the protective assembly disconnects the circuit, helping provide residual-current protection within the electrical installation.

The ABB DDA803 AC-63/0.03 adds this functionality to a compatible ABB S800 circuit breaker. Its 63 A current rating, 30 mA residual operating threshold and Type AC characteristic provide a practical solution for three-pole distribution circuits requiring sensitive detection of sinusoidal AC residual currents.

Typical Applications

  • Low-voltage electrical distribution boards.
  • Commercial and industrial electrical installations.
  • Three-pole circuits requiring residual-current protection.
  • ABB S800 circuit-breaker assemblies.
  • Distribution circuits requiring 30 mA residual-current sensitivity.
  • Applications requiring Type AC residual-current detection.

Technical Specifications

Series DDA800
ABB order code 2CSB803001R1630
Product type Residual current device (RCD) block
Number of poles 3
Rated current 63 A
Rated residual operating current 30 mA
Residual-current type AC
Application Residual-current protection with compatible ABB S800 series MCB

Frequently Asked Questions

What is the ABB DDA803 AC-63/0.03 used for?

The DDA803 AC-63/0.03 is a residual current device block used with a compatible ABB S800 series circuit breaker to provide residual-current protection in low-voltage electrical distribution systems.

What is the rated current of the DDA803 AC-63/0.03?

The ABB DDA803 AC-63/0.03 has a rated current of 63 A.

What is the residual operating current of the DDA803 AC-63/0.03?

The device has a rated residual operating current of 30 mA.

What does Type AC residual-current detection mean?

Type AC residual-current protection is designed to detect sinusoidal alternating residual currents.

How many poles does the ABB DDA803 AC-63/0.03 have?

The DDA803 AC-63/0.03 has a 3-pole configuration for use with compatible three-pole ABB S800 circuit-breaker assemblies.

Trusted ABB Residual-Current Protection

ABB DDA800 residual current device blocks extend compatible S800 circuit breakers with residual-current protection, providing a modular solution for low-voltage distribution systems requiring dependable earth-leakage fault detection and circuit disconnection.