2CSB802201R5630 ABB DDA802 A S-63/1 RCD Block 63 A 2P Type A S 1000 mA

2CSB802201R5630 ABB DDA802 A S-63/1 RCD Block 63 A 2P Type A S 1000 mA

ABB DDA802 A S-63/1 is a 63 A two-pole selective Type A RCD block with 1000 mA residual current sensitivity for coordinated residual current protection with compatible ABB S800 miniature circuit-breakers.

SKU: 2CSB802201R5630Alt SKU: DDA802AS631MPN: 2CSB802201R5630
Price
List Price £489.39 ex VAT
Your Price (ex VAT) Save 35%
£318.10 35% OFF
You save £171.29 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £318.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£318.10

Why Choose the ABB DDA802 A S-63/1 RCD Block?

The ABB DDA802 A S-63/1 is a two-pole Type A selective residual current device (RCD) block designed for combination with compatible ABB S800 miniature circuit-breakers. As part of the ABB DDA 800 series, it provides residual current protection for electrical distribution systems where selective coordination and continuity of supply are important.

Its Type A S characteristic combines detection of sinusoidal alternating and pulsating direct residual currents with selective time-delayed operation. This makes the DDA802 A S-63/1 suitable for upstream protection in installations containing downstream residual current protective devices, helping localise earth faults while reducing unnecessary disconnection of unaffected circuits.

With a rated current of 63 A, a rated residual operating current of 1000 mA and a two-pole configuration, the DDA802 A S-63/1 provides a practical solution for selective residual current protection. When assembled with a compatible ABB S800 MCB, it complements the circuit-breaker's overload and short-circuit protection with residual current protection.

Key Advantages

  • Selective Type A S residual current protection for coordinated electrical distribution systems.
  • 63 A rated current for commercial and industrial distribution circuits.
  • 1000 mA rated residual operating current for upstream earth fault protection.
  • Two-pole configuration for compatible electrical distribution applications.
  • Detects sinusoidal AC and pulsating DC residual currents.
  • Selective time-delayed response supports coordination with downstream residual current devices.
  • Designed for combination with compatible ABB S800 miniature circuit-breakers.

Key Features

  • ABB DDA 800 residual current device block series.
  • 63 A rated current.
  • 1000 mA residual current sensitivity.
  • Two-pole configuration.
  • Type A S selective residual current characteristic.
  • Detection of sinusoidal alternating and pulsating direct residual currents.
  • Selective time-delayed operation for coordinated residual current protection.
  • Designed for use with compatible ABB S800 MCBs.
  • Suitable for upstream and distribution-level residual current protection.
  • Designed for commercial and industrial electrical distribution systems.

Reliable Selective Residual Current Protection

Residual current protection monitors the balance of current flowing through the live conductors of a circuit and responds when earth leakage creates an imbalance above the specified operating threshold. The ABB DDA802 A S-63/1 provides Type A detection, allowing it to respond to both sinusoidal alternating residual currents and pulsating direct residual currents.

The selective time-delayed characteristic supports discrimination between upstream and downstream residual current protective devices. Combined with its 63 A rated current and 1000 mA residual operating threshold, the DDA802 A S-63/1 is well suited to distribution-level protection where coordinated fault isolation and continuity of supply are important.

Typical Applications

  • Main and sub-distribution electrical systems.
  • Commercial electrical distribution boards.
  • Industrial electrical installations.
  • Distribution systems using compatible ABB S800 miniature circuit-breakers.
  • Upstream residual current protection requiring selective operation.
  • Installations with cascaded downstream residual current protection.

Technical Specifications

Series DDA 800
Product group S800 / S800P / S750 MCB
Order code 2CSB802201R5630
Product type Selective residual current device (RCD) block
Residual current type Type A S (selective)
Number of poles 2
Rated current 63 A
Rated residual operating current 1000 mA
Equivalent residual current 1 A
Time characteristic Selective / time-delayed
MCB compatibility Compatible ABB S800 miniature circuit-breakers
Application Selective residual current protection for electrical distribution circuits

Frequently Asked Questions

What is the ABB DDA802 A S-63/1 used for?

The ABB DDA802 A S-63/1 is a two-pole selective Type A residual current device block designed for combination with compatible ABB S800 MCBs in electrical distribution systems requiring coordinated residual current protection.

What is the rated current of the DDA802 A S-63/1?

The DDA802 A S-63/1 has a rated current of 63 A.

What is the residual current sensitivity of the ABB DDA802 A S-63/1?

The DDA802 A S-63/1 has a rated residual operating current of 1000 mA, equivalent to 1 A.

What does Type A S mean on the DDA802 A S-63/1?

Type A indicates detection of sinusoidal alternating and pulsating direct residual currents, while S denotes selective time-delayed operation intended to support coordination with downstream residual current protective devices.

Which circuit-breakers can the ABB DDA802 A S-63/1 be used with?

The DDA802 A S-63/1 is designed for combination with compatible ABB S800 miniature circuit-breakers, adding selective residual current protection to the overload and short-circuit protection provided by the associated MCB.

Trusted ABB Residual Current Protection

ABB DDA 800 residual current blocks provide coordinated residual current protection in combination with compatible S800 miniature circuit-breakers, with selective Type A S versions designed for distribution systems where discrimination and continuity of supply are important.