2CSB802201R5000 ABB DDA802 A S-100/1 RCD Block 100 A 2P Type A S 1000 mA

2CSB802201R5000 ABB DDA802 A S-100/1 RCD Block 100 A 2P Type A S 1000 mA

ABB DDA802 A S-100/1 is a 100 A two-pole selective Type A RCD block with 1000 mA residual current sensitivity for coordinated residual current protection with compatible ABB S800 miniature circuit-breakers.

SKU: 2CSB802201R5000Alt SKU: DDA802AS1001MPN: 2CSB802201R5000
Price
List Price £860.11 ex VAT
Your Price (ex VAT) Save 35%
£559.07 35% OFF
You save £301.04 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £559.07
Trade pricing is personalised to your account

Manufacturer Lead Time

£559.07

Why Choose the ABB DDA802 A S-100/1 RCD Block?

The ABB DDA802 A S-100/1 is a high-performance two-pole Type A selective residual current device (RCD) block designed for combination with compatible ABB S800 miniature circuit-breakers. As part of the ABB DDA 800 series, it provides residual current protection for demanding electrical distribution systems where selective coordination with downstream residual current protection is required.

The Type A S characteristic combines detection of sinusoidal alternating and pulsating direct residual currents with a selective time-delayed response. This selective behaviour is particularly useful in cascaded protection systems, helping a downstream RCD clear a local earth fault before the upstream DDA802 A S-100/1 operates and thereby supporting continuity of supply to unaffected circuits.

With a rated current of 100 A, a rated residual operating current of 1000 mA and a two-pole configuration, the DDA802 A S-100/1 is designed for higher-current distribution applications. When correctly combined with a compatible ABB S800 MCB, it provides residual current protection alongside the overload and short-circuit protection of the associated circuit-breaker.

Key Advantages

  • Selective Type A S residual current protection for coordinated electrical distribution systems.
  • 100 A rated current suitable for higher-current distribution circuits.
  • 1000 mA rated residual operating current for upstream earth fault protection.
  • Two-pole configuration for compatible electrical distribution applications.
  • Detects sinusoidal AC and pulsating DC residual currents.
  • Selective time-delayed response supports coordination with downstream RCD protection.
  • Designed for combination with compatible ABB S800 miniature circuit-breakers.

Key Features

  • ABB DDA 800 residual current device block series.
  • 100 A rated current.
  • 1000 mA residual current sensitivity.
  • Two-pole configuration.
  • Type A S selective residual current characteristic.
  • Detection of sinusoidal alternating and pulsating direct residual currents.
  • Time-delayed selective operation for coordinated residual current protection.
  • Designed for use with compatible ABB S800 MCBs.
  • Suitable for upstream and distribution-level residual current protection.
  • Modular solution for commercial and industrial electrical distribution systems.

Reliable Selective Residual Current Protection

Residual current protection monitors the balance of current flowing through the live conductors of a circuit and responds when earth leakage creates an imbalance above the specified operating threshold. The ABB DDA802 A S-100/1 provides Type A detection, allowing it to respond to both sinusoidal alternating residual currents and pulsating direct residual currents.

The selective time delay of the Type A S design supports discrimination between upstream and downstream residual current protective devices. Combined with its 100 A rated current and 1000 mA residual operating threshold, the DDA802 A S-100/1 is particularly suited to upstream distribution protection where continuity of supply and coordinated fault isolation are important.

Typical Applications

  • Main and sub-distribution electrical systems.
  • Commercial electrical distribution boards.
  • Industrial electrical installations.
  • Distribution systems using compatible ABB S800 miniature circuit-breakers.
  • Upstream residual current protection requiring selective operation.
  • Installations with cascaded downstream RCD protection.

Technical Specifications

Series DDA 800
Product group S800 / S800P / S750 MCB
Order code 2CSB802201R5000
Product type Selective residual current device (RCD) block
Residual current type Type A S (selective)
Number of poles 2
Rated current 100 A
Rated residual operating current 1000 mA
Time characteristic Selective / time-delayed
MCB compatibility Compatible ABB S800 miniature circuit-breakers
Application Selective residual current protection for electrical distribution circuits

Frequently Asked Questions

What is the ABB DDA802 A S-100/1 used for?

The ABB DDA802 A S-100/1 is a two-pole selective Type A residual current device block designed for combination with compatible ABB S800 MCBs in electrical distribution systems requiring coordinated residual current protection.

What is the rated current of the DDA802 A S-100/1?

The DDA802 A S-100/1 has a rated current of 100 A, making it suitable for higher-current electrical distribution applications.

What is the residual current sensitivity of the ABB DDA802 A S-100/1?

The DDA802 A S-100/1 has a rated residual operating current of 1000 mA, equivalent to 1 A.

What does Type A S mean on the DDA802 A S-100/1?

Type A indicates detection of sinusoidal alternating and pulsating direct residual currents, while S denotes selective time-delayed operation intended to support coordination with downstream residual current protective devices.

Which circuit-breakers can the ABB DDA802 A S-100/1 be used with?

The DDA802 A S-100/1 is designed for combination with compatible ABB S800 miniature circuit-breakers, adding selective residual current protection to the overload and short-circuit protection provided by the associated MCB.

Trusted ABB Residual Current Protection

ABB DDA 800 residual current blocks provide coordinated residual current protection in combination with compatible S800 miniature circuit-breakers, with selective Type A S versions designed for distribution systems where discrimination and continuity of supply are important.