ABB DDA802 A S-100/0.3 is a 2-pole 100 A selective Type A residual current device block with 300 mA residual operating current for coordinated residual-current protection with compatible ABB S800 circuit breakers.
£533.21
The ABB DDA802 A S-100/0.3 is a 2-pole residual current device (RCD) block designed to provide residual-current protection when combined with a compatible ABB S800 series miniature circuit breaker. It provides a modular solution for adding earth-leakage protection to high-current low-voltage electrical distribution circuits.
Featuring an ABB AS residual-current characteristic, the DDA802 A S-100/0.3 combines Type A residual-current detection with selective time-delayed operation. It detects sinusoidal alternating and pulsating DC residual currents, while its selective behaviour supports coordination with downstream residual-current protective devices.
With a rated current of 100 A, a rated residual operating current of 300 mA and a 2-pole configuration, the DDA802 A S-100/0.3 is suitable for compatible two-pole ABB S800 circuit-breaker assemblies requiring selective residual-current protection. Its modular construction supports integration into professional electrical distribution boards and panel assemblies.
Selective residual-current protection is used to coordinate protective devices installed at different levels of an electrical distribution system. The time-delayed operation of an upstream selective RCD allows an appropriate downstream device to disconnect a local residual-current fault first, helping limit unnecessary interruption to other circuits.
The ABB DDA802 A S-100/0.3 combines this selective behaviour with Type A residual-current detection. Its 100 A current rating and 300 mA residual operating threshold make it suitable for upstream and distribution-level applications requiring coordinated residual-current protection.
| Series | DDA800 |
|---|---|
| ABB order code | 2CSB802201R3000 |
| Product type | Residual current device (RCD) block |
| Number of poles | 2 |
| Rated current | 100 A |
| Rated residual operating current | 300 mA |
| Residual-current characteristic | AS |
| Residual-current detection | Type A |
| Operating characteristic | Selective, time-delayed |
| Application | Residual-current protection with compatible ABB S800 series MCB |
The DDA802 A S-100/0.3 is a selective residual current device block used with a compatible ABB S800 series circuit breaker to provide residual-current protection in low-voltage electrical distribution systems.
The ABB DDA802 A S-100/0.3 has a rated current of 100 A.
The device has a rated residual operating current of 300 mA.
The AS characteristic combines Type A residual-current detection with selective time-delayed operation, supporting coordination with downstream residual-current protective devices.
The DDA802 A S-100/0.3 has a 2-pole configuration for use with compatible two-pole ABB S800 circuit-breaker assemblies.
ABB DDA800 residual current device blocks extend compatible S800 circuit breakers with residual-current protection, providing a modular solution for low-voltage distribution systems requiring dependable earth-leakage fault detection and coordinated circuit disconnection.