2CSB802101R4630 ABB DDA802 A-63/0.5 63 A 2-Pole Type A 500 mA Residual Current Device

2CSB802101R4630 ABB DDA802 A-63/0.5 63 A 2-Pole Type A 500 mA Residual Current Device

ABB DDA802 A-63/0.5 is a 63 A two-pole Type A residual current device with 500 mA rated residual operating current for earth-leakage protection in compatible electrical distribution installations.

SKU: 2CSB802101R4630Alt SKU: DDA802A630.5MPN: 2CSB802101R4630
Price
List Price £403.33 ex VAT
Your Price (ex VAT) Save 35%
£262.16 35% OFF
You save £141.17 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £262.16
Trade pricing is personalised to your account

Manufacturer Lead Time

£262.16

Why Choose the ABB DDA802 A-63/0.5 Residual Current Device?

The ABB DDA802 A-63/0.5 is a two-pole residual current device (RCD) designed to provide residual-current protection in electrical distribution installations. Rated at 63 A with a 500 mA residual operating current, this Type A device provides residual-current detection for applications requiring protection against both sinusoidal AC and pulsating DC residual currents.

As part of ABB's DDA800 range, the DDA802 A-63/0.5 provides residual-current functionality for compatible S800 high-performance circuit-breaker installations. When used in the appropriate ABB system configuration, it complements overcurrent protection by detecting earth-leakage conditions and disconnecting the protected circuit when the applicable residual-current threshold is reached.

The combination of a two-pole configuration, 63 A rated current, 500 mA sensitivity and Type A residual-current characteristic makes this model suitable for compatible commercial and industrial electrical distribution applications. ABB order code 2CSB802101R4630 identifies this specific DDA802 variant.

Key Advantages

  • 500 mA rated residual operating current for residual-current protection.
  • 63 A rated current for electrical distribution applications.
  • Two-pole configuration for compatible circuits.
  • Type A residual-current characteristic.
  • Detection of sinusoidal AC and pulsating DC residual currents.
  • Designed to complement overcurrent protection in compatible ABB S800 installations.
  • Supports coordinated residual-current and circuit protection within electrical distribution equipment.
  • ABB-engineered solution for professional electrical installations.

Key Features

  • ABB DDA802 residual current device.
  • 63 A rated current.
  • 500 mA rated residual operating current.
  • Two-pole design.
  • Type A residual-current detection.
  • Responds to sinusoidal AC and pulsating DC residual currents.
  • Designed for residual-current protection in compatible electrical distribution systems.
  • Suitable for use with the corresponding ABB S800 circuit-breaker system.
  • Provides earth-leakage fault detection as part of a correctly configured protective assembly.

Reliable Residual-Current Protection for Electrical Distribution

Residual-current protection monitors the balance of current flowing through a circuit and responds when leakage to earth produces a residual current above the device's operating threshold. With a rated residual operating current of 500 mA, the ABB DDA802 A-63/0.5 provides residual-current fault detection for compatible electrical distribution systems requiring a Type A device.

The DDA802 is intended to work as part of ABB's compatible high-performance circuit protection system rather than replacing the overcurrent protection function of the associated circuit breaker. Its Type A characteristic enables detection of both sinusoidal alternating and pulsating direct residual currents, while the 63 A current rating supports a wide range of distribution applications.

Typical Applications

  • Electrical distribution systems requiring 500 mA residual-current protection.
  • Compatible ABB S800 circuit-breaker installations.
  • Commercial electrical distribution boards.
  • Industrial electrical distribution equipment.
  • Building electrical installations requiring Type A residual-current detection.
  • Circuits requiring residual-current protection alongside compatible overcurrent protection.

Technical Specifications

Series DDA800
ABB order code 2CSB802101R4630
Product group S800 / S800P / S750 MCB
Product type Residual current device (RCD)
Number of poles 2
Rated current 63 A
Rated residual operating current 500 mA
Residual-current type A
Residual-current detection Sinusoidal AC and pulsating DC residual currents

Frequently Asked Questions

What is the ABB DDA802 A-63/0.5 used for?

The ABB DDA802 A-63/0.5 is a residual current device designed to provide earth-leakage protection in compatible electrical distribution installations, with a rated residual operating current of 500 mA.

What is the rated current of the ABB DDA802 A-63/0.5?

The DDA802 A-63/0.5 has a rated current of 63 A and a two-pole configuration.

What is the residual-current sensitivity of the DDA802 A-63/0.5?

The device has a rated residual operating current of 500 mA.

What does Type A mean on the ABB DDA802 A-63/0.5?

Type A means the device is designed to detect sinusoidal alternating residual currents as well as pulsating direct residual currents, making it suitable for applications where these residual-current waveforms may occur.

Does the ABB DDA802 A-63/0.5 provide overcurrent protection?

The DDA802 provides the residual-current protection function and is intended for use with a compatible ABB circuit breaker that provides the required overload and short-circuit protection within the assembled protective system.

Trusted Residual-Current Protection from ABB

ABB DDA800 residual current devices complement compatible high-performance circuit breakers with dependable earth-leakage detection for coordinated electrical distribution protection.