2CSB802101R3000 ABB DDA802 A-100/0.3 RCD Block 100 A 2P Type A 300 mA

2CSB802101R3000 ABB DDA802 A-100/0.3 RCD Block 100 A 2P Type A 300 mA

ABB DDA802 A-100/0.3 is a 100 A two-pole Type A residual current device block with 300 mA residual current sensitivity for use with compatible ABB S800 miniature circuit-breakers.

SKU: 2CSB802101R3000Alt SKU: DDA802A1000.3MPN: 2CSB802101R3000
Price
List Price £503.26 ex VAT
Your Price (ex VAT) Save 35%
£327.12 35% OFF
You save £176.14 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £327.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£327.12

Why Choose the ABB DDA802 A-100/0.3 RCD Block?

The ABB DDA802 A-100/0.3 is a high-performance two-pole Type A residual current device (RCD) block designed for assembly with compatible ABB S800 miniature circuit-breakers. As part of the ABB DDA 800 series, it provides residual current protection against sinusoidal alternating and pulsating direct earth fault currents in commercial and industrial electrical installations.

When combined with a compatible S800 MCB, the DDA802 A-100/0.3 enables residual current and overcurrent protection to be incorporated into a coordinated modular protective assembly. Its Type A detection characteristic makes it suitable for modern electrical circuits containing equipment capable of producing pulsating DC residual currents as well as conventional sinusoidal AC residual currents.

With a rated current of 100 A, a rated residual operating current of 300 mA and a two-pole configuration, the DDA802 A-100/0.3 is intended for higher-current commercial and industrial distribution applications. It is designed for use with ABB S800 MCBs up to 100 A and complies with IEC/EN 60947-2 Annex B.

Key Advantages

  • High-capacity Type A residual current protection for commercial and industrial installations.
  • 100 A rated current suitable for higher-current distribution circuits.
  • 300 mA rated residual operating current for earth fault protection.
  • Two-pole configuration for compatible electrical distribution applications.
  • Detects sinusoidal AC and pulsating DC residual currents.
  • Designed for on-site assembly with compatible ABB S800 MCBs up to 100 A.
  • Combination with an S800 MCB provides residual current, overload and short-circuit protection within a coordinated assembly.

Key Features

  • ABB DDA 800 residual current device block series.
  • 100 A rated current.
  • 300 mA residual current sensitivity.
  • Two-pole configuration.
  • Type A residual current characteristic.
  • 230 / 240 / 400 V rated voltage.
  • Rated frequency of 50–60 Hz.
  • IP2X protection rating.
  • Designed for combination with ABB S800 MCBs.
  • Protection against sinusoidal alternating and pulsating direct earth fault currents.
  • Suitable for commercial and industrial electrical installations.
  • Complies with IEC/EN 60947-2 Annex B.

Reliable Residual Current Protection for Electrical Distribution

Residual current protection detects an imbalance between the current flowing through live conductors and returning through the circuit, allowing earth leakage faults to be identified and disconnected when the specified operating threshold is reached. The ABB DDA802 A-100/0.3 provides Type A detection, enabling protection against both sinusoidal alternating and pulsating direct residual currents.

The DDA 800 series is specifically designed for on-site assembly with ABB S800 miniature circuit-breakers up to 100 A. When correctly combined with a compatible MCB, the DDA802 A-100/0.3 adds 300 mA residual current protection to the MCB's overcurrent and short-circuit protection, creating a comprehensive protective solution for commercial and industrial distribution circuits.

Typical Applications

  • Commercial electrical distribution systems.
  • Industrial electrical installations.
  • Distribution boards using ABB S800 miniature circuit-breakers.
  • Higher-current circuits requiring residual current protection.
  • Circuits requiring detection of AC and pulsating DC earth fault currents.
  • Electrical distribution systems requiring combined residual current and overcurrent protection.

Technical Specifications

Series DDA 800
Product group S800 / S800P / S750 MCB
Order code 2CSB802101R3000
EAN 8012542545033
Product type Residual current device (RCD) block
Residual current type Type A
Number of poles 2
Rated current 100 A
Rated residual current 300 mA
Rated voltage 230 / 240 / 400 V
Rated frequency 50–60 Hz
Protection rating IP2X
MCB compatibility ABB S800 series up to 100 A
Dimensions (W × H × D) 81 × 108.2 × 82.3 mm
Weight approx. 0.415 kg
Pack quantity 1 piece
Standard IEC/EN 60947-2 Annex B

Frequently Asked Questions

What is the ABB DDA802 A-100/0.3 used for?

The ABB DDA802 A-100/0.3 is a Type A residual current device block designed for assembly with compatible ABB S800 MCBs to provide residual current protection in commercial and industrial electrical installations.

What is the rated current of the DDA802 A-100/0.3?

The DDA802 A-100/0.3 has a rated current of 100 A and is designed for use with compatible ABB S800 miniature circuit-breakers up to 100 A.

What is the residual current sensitivity of the ABB DDA802 A-100/0.3?

The DDA802 A-100/0.3 has a rated residual operating current of 300 mA.

What does Type A mean on the DDA802 A-100/0.3?

Type A means the RCD block is designed to detect sinusoidal alternating residual currents and pulsating direct residual currents, making it suitable for a wide range of modern electrical loads.

Which circuit-breakers can the ABB DDA802 A-100/0.3 be used with?

The DDA802 A-100/0.3 is designed for on-site assembly with compatible ABB S800 miniature circuit-breakers up to 100 A.

Trusted ABB Residual Current Protection

ABB DDA 800 residual current blocks are designed for combination with S800 miniature circuit-breakers, providing Type A residual current protection for demanding commercial and industrial electrical distribution applications.