2CSB802101R1630 ABB DDA802 A-63/0.03 RCD Block 2P Type A 63A 30mA

2CSB802101R1630 ABB DDA802 A-63/0.03 RCD Block 2P Type A 63A 30mA

ABB DDA802 A-63/0.03 is a 2-pole Type A residual current device block rated at 63 A with 30 mA residual operating current for adding residual-current protection to compatible ABB S800 circuit-breaker assemblies.

SKU: 2CSB802101R1630Alt SKU: DDA802A630.03MPN: 2CSB802101R1630
Price
List Price £538.19 ex VAT
Your Price (ex VAT) Save 35%
£349.82 35% OFF
You save £188.37 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £349.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£349.82

Why Choose the ABB DDA802 A-63/0.03 Residual Current Device?

The ABB DDA802 A-63/0.03 is a 2-pole residual current device (RCD) block designed to provide residual-current protection when combined with a compatible ABB S800 series miniature circuit breaker. It provides a modular solution for adding earth-leakage protection to low-voltage electrical distribution circuits.

Featuring Type A residual-current detection, the DDA802 A-63/0.03 is designed to detect sinusoidal alternating residual currents as well as pulsating DC residual currents. Its rated residual operating current of 30 mA provides sensitive residual-current protection for applications requiring this operating threshold.

With a rated current of 63 A and a 2-pole configuration, the DDA802 A-63/0.03 is suitable for compatible two-pole ABB S800 circuit-breaker assemblies. Its modular construction supports integration into professional electrical distribution boards and control panels requiring combined overcurrent and residual-current protection.

Key Advantages

  • 30 mA rated residual operating current for sensitive residual-current protection.
  • 63 A rated current for compatible distribution circuits.
  • 2-pole configuration for two-pole circuit-breaker assemblies.
  • Type A detection for sinusoidal AC and pulsating DC residual currents.
  • Designed for combination with compatible ABB S800 series MCBs.
  • Modular construction supports integration into distribution-board assemblies.

Key Features

  • ABB DDA800 series residual current device block.
  • 63 A rated current.
  • 30 mA rated residual operating current.
  • 2-pole construction.
  • Type A residual-current characteristic.
  • Detection of sinusoidal AC and pulsating DC residual currents.
  • Provides residual-current protection when assembled with a compatible circuit breaker.
  • Designed for low-voltage electrical distribution applications.

Type A Residual-Current Protection for S800 Circuit Breaker Assemblies

Type A residual current devices respond to sinusoidal alternating residual currents and pulsating DC residual currents, providing broader residual-current detection than Type AC devices. This makes them suitable for circuits containing electrical and electronic equipment capable of producing pulsating DC fault-current components.

The ABB DDA802 A-63/0.03 adds this residual-current functionality to a compatible ABB S800 circuit breaker. Its 63 A current rating, 30 mA residual operating threshold and Type A characteristic provide a practical solution for two-pole distribution circuits requiring sensitive earth-leakage protection.

Typical Applications

  • Low-voltage electrical distribution boards.
  • Commercial and industrial electrical installations.
  • Two-pole circuits requiring residual-current protection.
  • ABB S800 circuit-breaker assemblies.
  • Distribution circuits requiring 30 mA residual-current sensitivity.
  • Applications requiring Type A residual-current detection.

Technical Specifications

Series DDA800
ABB order code 2CSB802101R1630
Product type Residual current device (RCD) block
Number of poles 2
Rated current 63 A
Rated residual operating current 30 mA
Residual-current type A
Application Residual-current protection with compatible ABB S800 series MCB

Frequently Asked Questions

What is the ABB DDA802 A-63/0.03 used for?

The DDA802 A-63/0.03 is a residual current device block used with a compatible ABB S800 series circuit breaker to provide residual-current protection in low-voltage electrical distribution systems.

What is the rated current of the DDA802 A-63/0.03?

The ABB DDA802 A-63/0.03 has a rated current of 63 A.

What is the residual operating current of the DDA802 A-63/0.03?

The device has a rated residual operating current of 30 mA.

What does Type A residual-current detection mean?

Type A residual-current protection detects sinusoidal AC and pulsating DC residual currents, making it suitable for circuits where electronic equipment may generate pulsating DC fault-current components.

How many poles does the ABB DDA802 A-63/0.03 have?

The DDA802 A-63/0.03 has a 2-pole configuration for use with compatible two-pole ABB S800 circuit-breaker assemblies.

Trusted ABB Residual-Current Protection

ABB DDA800 residual current device blocks extend compatible S800 circuit breakers with residual-current protection, providing a modular solution for low-voltage distribution systems requiring dependable earth-leakage fault detection and circuit disconnection.