ABB DDA204 AC-40/0.1 is a 4-pole Type AC RCD block rated at 40 A with a 100 mA residual operating current and 230/400 V AC rating for use with compatible ABB circuit breakers.

SKU: 2CSB204001R2400Alt SKU: DDA204AC400.1MPN: 2CSB204001R2400
Price
List Price £141.17 ex VAT
Your Price (ex VAT) Save 35%
£91.76 35% OFF
You save £49.41 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £91.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£91.76

Why Choose the ABB DDA204 AC-40/0.1 RCD Block?

The ABB DDA204 AC-40/0.1 is a reliable 4-pole Type AC residual current device (RCD) block designed to provide residual current protection when assembled with compatible ABB miniature circuit breakers. As part of the established ABB DDA200 RCD series, it provides protection against sinusoidal alternating earth fault currents in residential, commercial and industrial electrical installations.

Designed for assembly with compatible ABB S200 series miniature circuit breakers, the DDA204 AC-40/0.1 enables residual current protection to be combined with the overcurrent and short-circuit protection provided by the associated circuit breaker. Its four-pole configuration makes it suitable for compatible three-phase systems incorporating a neutral conductor.

With a rated current of 40 A, a rated residual operating current of 100 mA and a rated voltage of 230/400 V AC, the DDA204 AC-40/0.1 provides dependable earth leakage protection for suitable electrical distribution applications. Its modular construction enables straightforward integration into distribution boards and control panels.

Key Advantages

  • Reliable residual current protection for four-pole electrical circuits.
  • 40 A rated current for suitable residential, commercial and industrial applications.
  • 100 mA rated residual operating current.
  • Type AC detection for sinusoidal alternating residual currents.
  • Designed for assembly with compatible ABB S200 series miniature circuit breakers.
  • Modular design supports convenient integration into electrical distribution systems.

Key Features

  • ABB DDA200 RCD series.
  • 4-pole RCD block.
  • 40 A rated current.
  • 100 mA rated residual current.
  • Type AC residual current characteristic.
  • 230/400 V AC rated voltage.
  • 50–60 Hz rated frequency.
  • 500 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • IP2X protection rating.

Reliable Type AC Residual Current Protection

Residual current devices monitor electrical circuits for current imbalances caused by leakage to earth. The ABB DDA204 AC-40/0.1 uses a Type AC residual current characteristic and is designed to respond to sinusoidal alternating residual currents, providing dependable earth leakage protection in suitable conventional AC electrical circuits.

The ABB DDA200 range is designed for assembly with compatible ABB modular circuit breakers. When combined with a suitable circuit breaker, the RCD block provides residual current protection alongside the overcurrent and short-circuit protection of the associated breaker, creating a compact protection solution for residential, commercial and industrial electrical distribution systems.

Typical Applications

  • Three-phase electrical distribution systems with neutral.
  • Commercial building distribution boards.
  • Industrial electrical panels and switchboards.
  • Residential electrical distribution systems.
  • Conventional AC electrical loads and circuits.
  • Circuits requiring 100 mA Type AC residual current protection.

Technical Specifications

Series DDA200 RCD
ABB order code 2CSB204001R2400
EAN 8012542794301
Product type Residual current device (RCD) block
Residual current type Type AC
Number of poles 4
Rated current 40 A
Rated residual current 100 mA
Rated voltage 230/400 V AC
Rated operational voltage 230/400 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Rated frequency 50–60 Hz
Protection rating IP2X
Standard IEC/EN 61009 Ann. G
Dimensions (W × H × D) 105 × 93 × 76 mm
Net weight approx. 0.260 kg

Frequently Asked Questions

What is the ABB DDA204 AC-40/0.1 used for?

The DDA204 AC-40/0.1 is a 4-pole residual current device block designed to provide Type AC residual current protection when assembled with a compatible ABB miniature circuit breaker.

What is the rated current of the DDA204 AC-40/0.1?

The ABB DDA204 AC-40/0.1 has a rated current of 40 A.

What is the residual current rating?

The DDA204 AC-40/0.1 has a rated residual operating current of 100 mA.

What does Type AC mean on this RCD block?

Type AC means the device is designed to respond to sinusoidal alternating residual currents. For circuits capable of producing pulsating or smooth DC residual currents, an appropriate alternative RCD type should be selected according to the application.