2CSB203701R4630 ABB DDA203A630.5AE DDA203 A-63/0.5 AE RCD Block 3P Type A 63 A 500 mA

2CSB203701R4630 ABB DDA203A630.5AE DDA203 A-63/0.5 AE RCD Block 3P Type A 63 A 500 mA

ABB DDA203A630.5AE DDA203 A-63/0.5 AE is a 3-pole 63 A 500 mA Type A residual current device block for detecting sinusoidal AC and pulsating DC residual currents with compatible ABB miniature circuit breakers.

SKU: 2CSB203701R4630Alt SKU: DDA203A630.5AEMPN: 2CSB203701R4630
Price
List Price £360.97 ex VAT
Your Price (ex VAT) Save 35%
£234.63 35% OFF
You save £126.34 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £234.63
Trade pricing is personalised to your account

Manufacturer Lead Time

£234.63

Why Choose the ABB DDA203A630.5AE Residual Current Device Block?

The ABB DDA203A630.5AE, manufacturer type DDA203 A-63/0.5 AE, is a 3-pole Type A residual current device (RCD) block from the ABB DDA200 range. Designed for combination with compatible ABB miniature circuit breakers, it provides residual-current protection for suitable three-phase commercial and industrial electrical distribution circuits.

The DDA203 A-63/0.5 AE is designed to detect both sinusoidal AC and pulsating DC residual currents. This Type A characteristic provides broader residual-current detection than Type AC devices and supports applications containing modern electrical and electronic equipment capable of producing pulsating DC earth-leakage currents.

With a rated current of 63 A, a rated residual operating current of 500 mA and a 3-pole configuration, the DDA203A630.5AE is suited to applications requiring this higher residual-current threshold. When correctly assembled with a compatible ABB miniature circuit breaker, the resulting combination provides residual-current protection together with overload and short-circuit protection.

Key Advantages

  • Type A residual-current detection for sinusoidal AC and pulsating DC residual currents.
  • 63 A rated current for higher-current compatible circuits.
  • 500 mA rated residual operating current for applications specifying this earth-leakage threshold.
  • 3-pole configuration for suitable three-phase circuit arrangements.
  • Suitable for installations incorporating electrical and electronic loads.
  • Designed for combination with compatible ABB miniature circuit breakers.
  • Part of ABB's modular DDA200 residual current device block range.

Key Features

  • ABB DDA200 residual current device block series.
  • Type A residual-current characteristic.
  • AE variant.
  • 63 A rated current.
  • 500 mA rated residual operating current.
  • 3 poles.
  • Detection of sinusoidal AC and pulsating DC residual currents.
  • Modular construction for combination with compatible ABB miniature circuit breakers.

Reliable Type A Protection for Three-Phase Circuits

Type A residual-current protection responds to sinusoidal alternating residual currents as well as pulsating DC residual currents. This makes the ABB DDA203 A-63/0.5 AE suitable for compatible electrical installations where electronic equipment or rectifier-based loads can produce residual-current waveforms requiring Type A detection.

The 500 mA residual-current operating threshold is intended for applications specifically designed around a higher earth-leakage trip level rather than sensitive 30 mA additional protection. The modular DDA200 construction allows the RCD block to be paired with a compatible ABB miniature circuit breaker to provide coordinated residual-current, overload and short-circuit protection.

Typical Applications

  • Three-phase commercial electrical distribution systems.
  • Industrial electrical installations.
  • Distribution boards and sub-distribution panels.
  • Electrical control and automation panels.
  • Circuits containing electronic equipment capable of producing pulsating DC residual currents.
  • Circuits requiring 500 mA Type A residual-current protection.
  • Assemblies using compatible ABB miniature circuit breakers.

Technical Specifications

Series DDA200
SKU DDA203A630.5AE
ABB order code 2CSB203701R4630
Product type Residual current device block / RCD block
Variant AE
Residual-current type Type A
Number of poles 3
Rated current 63 A
Rated residual operating current 500 mA
Rated frequency 50–60 Hz
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Protection rating IP2X
Standard IEC/EN 61009 Annex G

Frequently Asked Questions

What is the ABB DDA203A630.5AE used for?

The ABB DDA203A630.5AE is a 3-pole Type A RCD block designed for combination with compatible ABB miniature circuit breakers to provide residual-current protection for suitable three-phase electrical circuits.

What is the rated current of the DDA203 A-63/0.5 AE?

The ABB DDA203 A-63/0.5 AE has a rated current of 63 A.

What is the residual-current sensitivity of the DDA203A630.5AE?

The DDA203A630.5AE has a rated residual operating current of 500 mA.

What residual currents can the ABB DDA203A630.5AE detect?

As a Type A device, it is designed to detect sinusoidal alternating residual currents and pulsating DC residual currents.

How many poles does the ABB DDA203A630.5AE have?

The DDA203A630.5AE is a 3-pole residual current device block for suitable three-phase circuit arrangements.

Trusted ABB Type A Circuit Protection