2CSB203199R1630 ABB DDA203A630.03110V DDA203 A-63/0.03 110V RCD Block 3P Type A 63 A 30 mA

2CSB203199R1630 ABB DDA203A630.03110V DDA203 A-63/0.03 110V RCD Block 3P Type A 63 A 30 mA

ABB DDA203A630.03110V DDA203 A-63/0.03 110V is a 3-pole 63 A 30 mA Type A residual current device block for 110 V applications, designed to detect sinusoidal AC and pulsating DC residual currents.

SKU: 2CSB203199R1630Alt SKU: DDA203A630.03110VMPN: 2CSB203199R1630
Price
List Price £209.56 ex VAT
Your Price (ex VAT) Save 35%
£136.21 35% OFF
You save £73.35 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £136.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£136.21

Why Choose the ABB DDA203A630.03110V Residual Current Device Block?

The ABB DDA203A630.03110V, manufacturer type DDA203 A-63/0.03 110V, is a 3-pole Type A residual current device (RCD) block designed for 110 V applications and combination with compatible ABB miniature circuit breakers. Part of the ABB DDA200 RCD series, it provides residual-current protection for suitable three-phase electrical circuits.

The DDA203 A-63/0.03 110V is designed to detect both sinusoidal AC and pulsating DC residual currents. Its Type A characteristic makes it suitable for electrical installations containing electronic equipment capable of producing pulsating DC earth-leakage currents in addition to conventional alternating residual currents.

With a rated current of 63 A, a rated residual operating current of 30 mA, a 3-pole configuration and a dedicated 110 V version, the DDA203A630.03110V provides sensitive residual-current detection for appropriate low-voltage distribution applications. When assembled with a compatible ABB miniature circuit breaker, it supports coordinated residual-current, overload and short-circuit protection.

Key Advantages

  • Type A residual-current protection for sinusoidal AC and pulsating DC residual currents.
  • 30 mA sensitivity for sensitive earth-leakage detection.
  • 63 A rated current for higher-current compatible circuits.
  • 110 V version for compatible low-voltage applications.
  • 3-pole configuration for suitable three-phase circuit arrangements.
  • Suitable for circuits containing electrical and electronic equipment.
  • Designed for combination with compatible ABB miniature circuit breakers.

Key Features

  • ABB DDA200 residual current device block series.
  • Type A residual-current characteristic.
  • 63 A rated current.
  • 30 mA rated residual operating current.
  • 110 V version.
  • 3 poles.
  • Detection of sinusoidal AC and pulsating DC residual currents.
  • Modular construction for use with compatible ABB miniature circuit breakers.
  • Suitable for electrical distribution and control-panel applications requiring the specified voltage and residual-current characteristics.

Reliable Type A Protection for 110 V Applications

Type A residual-current protection responds to sinusoidal alternating residual currents as well as pulsating DC residual currents. This broader detection capability makes the ABB DDA203 A-63/0.03 110V suitable for compatible installations containing electronic components and rectifier-based equipment where Type A residual-current detection is required.

The 30 mA operating sensitivity provides sensitive earth-leakage detection, while the dedicated 110 V configuration addresses applications requiring this voltage version. The modular DDA200 design allows the RCD block to be combined with a compatible ABB miniature circuit breaker to provide residual-current protection together with overload and short-circuit protection.

Typical Applications

  • Electrical distribution systems requiring a 110 V RCD block.
  • Commercial and industrial electrical installations.
  • Electrical control and automation panels.
  • Distribution boards for compatible low-voltage circuits.
  • Circuits containing electronic equipment capable of producing pulsating DC residual currents.
  • Applications requiring 30 mA Type A residual-current protection.
  • Assemblies using compatible ABB miniature circuit breakers.

Technical Specifications

Series DDA200
SKU DDA203A630.03110V
ABB order code 2CSB203199R1630
Product type Residual current device block / RCD block
Residual-current type Type A
Number of poles 3
Rated current 63 A
Rated residual operating current 30 mA
Voltage version 110 V
Rated frequency 50–60 Hz
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Protection rating IP2X
Standard IEC/EN 61009 Annex G

Frequently Asked Questions

What is the ABB DDA203A630.03110V used for?

The ABB DDA203A630.03110V is a 3-pole Type A RCD block designed for 110 V applications and combination with compatible ABB miniature circuit breakers to provide residual-current protection.

What is the rated current of the DDA203 A-63/0.03 110V?

The ABB DDA203 A-63/0.03 110V has a rated current of 63 A.

What is the residual-current sensitivity of the DDA203A630.03110V?

The DDA203A630.03110V has a rated residual operating current of 30 mA.

What does Type A mean on the ABB DDA203A630.03110V?

Type A means the device is designed to detect both sinusoidal alternating and pulsating DC residual currents, making it suitable for many circuits containing electronic equipment.

What voltage version is the ABB DDA203A630.03110V?

The DDA203A630.03110V is the 110 V version of the DDA203 A-63/0.03 residual current device block.

Trusted ABB Type A Circuit Protection

ABB DDA200 Type A residual current device blocks provide modular protection against AC and pulsating DC earth-leakage currents, with dedicated variants supporting the voltage and protection requirements of specialised electrical installations.