ABB DDA203A250.5 DDA203 A-25/0.5 is a 3-pole 25 A 500 mA Type A residual current device block for detecting sinusoidal AC and pulsating DC residual currents with compatible ABB miniature circuit breakers.

SKU: 2CSB203101R4250Alt SKU: DDA203A250.5MPN: 2CSB203101R4250
Price
List Price £138.02 ex VAT
Your Price (ex VAT) Save 35%
£89.71 35% OFF
You save £48.31 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £89.71
Trade pricing is personalised to your account

Manufacturer Lead Time

£89.71

Why Choose the ABB DDA203A250.5 Residual Current Device Block?

The ABB DDA203A250.5, manufacturer type DDA203 A-25/0.5, is a 3-pole Type A residual current device (RCD) block designed for combination with compatible ABB miniature circuit breakers. Part of the ABB DDA200 RCD series, it provides residual-current protection for suitable three-phase electrical distribution circuits in commercial and industrial installations.

The DDA203 A-25/0.5 is designed to detect both sinusoidal AC and pulsating DC residual currents. This Type A characteristic makes it suitable for circuits containing electrical and electronic equipment that may produce pulsating DC earth-leakage currents in addition to conventional alternating residual currents.

With a rated current of 25 A, a rated residual operating current of 500 mA and a 3-pole configuration, the DDA203A250.5 provides earth-leakage detection for suitable three-phase circuits. When assembled with a compatible ABB miniature circuit breaker, it forms a coordinated modular solution combining residual-current protection with overload and short-circuit protection.

Key Advantages

  • Type A residual-current protection for sinusoidal AC and pulsating DC residual currents.
  • 25 A rated current for compatible three-phase circuits.
  • 500 mA rated residual operating current.
  • 3-pole configuration for suitable three-phase applications.
  • Suitable for circuits containing modern electrical and electronic equipment.
  • Designed for combination with compatible ABB miniature circuit breakers.
  • Enables residual-current protection to be combined with overload and short-circuit protection.

Key Features

  • ABB DDA200 residual current device block series.
  • Type A residual-current characteristic.
  • 25 A rated current.
  • 500 mA rated residual operating current.
  • 3 poles.
  • Detection of sinusoidal AC and pulsating DC residual currents.
  • Modular construction for use with compatible ABB miniature circuit breakers.
  • Suitable for commercial and industrial three-phase electrical distribution.

Reliable Type A Protection for Three-Phase Circuits

Type A residual-current protection responds to sinusoidal alternating residual currents as well as pulsating DC residual currents. This detection capability makes the ABB DDA203 A-25/0.5 suitable for electrical installations containing electronic components and rectifier-based loads that can produce residual-current waveforms requiring Type A protection.

The 500 mA residual-current operating threshold is intended for applications where a higher earth-leakage trip level is specified rather than sensitive additional protection. The DDA200 modular design allows the RCD block to be combined with a compatible ABB miniature circuit breaker, providing residual-current protection together with overload and short-circuit protection in a coordinated assembly.

Typical Applications

  • Three-phase commercial electrical distribution systems.
  • Industrial electrical installations.
  • Distribution boards and sub-distribution panels.
  • Electrical control and automation panels.
  • Circuits containing electronic equipment capable of producing pulsating DC residual currents.
  • Three-phase circuits requiring 500 mA Type A residual-current protection.
  • Assemblies using compatible ABB miniature circuit breakers.

Technical Specifications

Series DDA200
SKU DDA203A250.5
ABB order code 2CSB203101R4250
Product type Residual current device block / RCD block
Residual-current type Type A
Number of poles 3
Rated current 25 A
Rated residual operating current 500 mA
Rated frequency 50–60 Hz
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Protection rating IP2X
Standard IEC/EN 61009 Annex G

Frequently Asked Questions

What is the ABB DDA203A250.5 used for?

The ABB DDA203A250.5 is a 3-pole Type A RCD block designed for combination with compatible ABB miniature circuit breakers to provide residual-current protection for suitable three-phase electrical circuits.

What is the rated current of the DDA203 A-25/0.5?

The ABB DDA203 A-25/0.5 has a rated current of 25 A.

What is the residual-current sensitivity of the DDA203A250.5?

The DDA203A250.5 has a rated residual operating current of 500 mA.

What does Type A mean on the ABB DDA203A250.5?

Type A means the device is designed to detect both sinusoidal alternating and pulsating DC residual currents, making it suitable for many circuits containing modern electronic equipment.

How many poles does the ABB DDA203A250.5 have?

The DDA203A250.5 is a 3-pole residual current device block intended for suitable three-phase circuit arrangements.

Trusted ABB Type A Circuit Protection

ABB DDA200 Type A residual current device blocks provide modular protection against AC and pulsating DC earth-leakage currents, supporting dependable three-phase circuit protection in commercial and industrial electrical installations.