2CSB203001R4630 ABB DDA203AC630.5 DDA203 AC-63/0.5 RCD Block 3P Type AC 63 A 500 mA

2CSB203001R4630 ABB DDA203AC630.5 DDA203 AC-63/0.5 RCD Block 3P Type AC 63 A 500 mA

ABB DDA203AC630.5 DDA203 AC-63/0.5 is a 3-pole 63 A 500 mA Type AC residual current device block designed for residual-current protection of suitable three-phase circuits with compatible ABB miniature circuit breakers.

SKU: 2CSB203001R4630Alt SKU: DDA203AC630.5MPN: 2CSB203001R4630
Price
List Price £174.08 ex VAT
Your Price (ex VAT) Save 35%
£113.15 35% OFF
You save £60.93 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £113.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£113.15

Why Choose the ABB DDA203AC630.5 Residual Current Device Block?

The ABB DDA203AC630.5, manufacturer type DDA203 AC-63/0.5, is a 3-pole Type AC residual current device (RCD) block designed for combination with compatible ABB miniature circuit breakers. As part of the ABB DDA200 RCD series, it provides residual-current protection for three-phase electrical distribution circuits in commercial and industrial installations.

The DDA203 AC-63/0.5 is designed to detect sinusoidal alternating residual currents. When assembled with a compatible ABB miniature circuit breaker, the DDA200 residual-current block allows earth-fault protection to be combined with overload and short-circuit protection in a coordinated modular protective device.

With a rated current of 63 A, a rated residual operating current of 500 mA and a 3-pole configuration, the DDA203AC630.5 is suitable for three-phase distribution circuits requiring Type AC residual-current detection. Its modular construction makes it well suited to distribution boards, switchboards and control panels using ABB modular circuit-protection equipment.

Key Advantages

  • Type AC residual-current protection for sinusoidal alternating earth-leakage currents.
  • 63 A rated current for three-phase electrical distribution circuits.
  • 500 mA rated residual operating current.
  • 3-pole configuration for suitable three-phase applications.
  • Modular construction for combination with compatible ABB miniature circuit breakers.
  • Supports coordinated residual-current, overload and short-circuit protection.
  • Suitable for commercial and industrial electrical distribution systems.

Key Features

  • ABB DDA200 residual current device block series.
  • Type AC residual-current characteristic.
  • 63 A rated current.
  • 500 mA residual-current sensitivity.
  • 3 poles.
  • Designed to respond to sinusoidal alternating residual currents.
  • Modular design for use with compatible ABB miniature circuit breakers.
  • Suitable for three-phase electrical distribution and control-panel applications.

Reliable Residual-Current Protection for Three-Phase Circuits

Residual current protection monitors the balance of current flowing through the conductors of a circuit and operates when leakage to earth exceeds the specified threshold. The ABB DDA203 AC-63/0.5 provides Type AC detection for sinusoidal alternating residual currents, supporting dependable earth-fault protection in suitable three-phase electrical systems.

The DDA200 modular concept allows the residual-current block to be assembled with a compatible ABB miniature circuit breaker. This provides a coordinated solution combining residual-current detection with overload and short-circuit protection while supporting compact installation within electrical distribution boards and control panels.

Typical Applications

  • Three-phase commercial electrical distribution systems.
  • Industrial electrical installations.
  • Distribution boards and sub-distribution panels.
  • Electrical control and automation panels.
  • Three-phase circuits requiring Type AC residual-current protection.
  • Building services and fixed electrical installations.
  • Assemblies using compatible ABB miniature circuit breakers.

Technical Specifications

Series DDA200
SKU DDA203AC630.5
ABB order code 2CSB203001R4630
Product type Residual current device block / RCD block
Residual-current type Type AC
Number of poles 3
Rated current 63 A
Rated residual operating current 500 mA
Rated frequency 50–60 Hz
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Protection rating IP2X
Standard IEC/EN 61009 Annex G

Frequently Asked Questions

What is the ABB DDA203AC630.5 used for?

The ABB DDA203AC630.5 is a 3-pole Type AC RCD block designed for combination with compatible ABB miniature circuit breakers to provide residual-current protection for suitable three-phase electrical circuits.

What is the rated current of the DDA203 AC-63/0.5?

The ABB DDA203 AC-63/0.5 has a rated current of 63 A.

What is the residual-current sensitivity of this RCD block?

The DDA203 AC-63/0.5 has a rated residual operating current of 500 mA.

How many poles does the ABB DDA203AC630.5 have?

The DDA203AC630.5 is a 3-pole residual current device block designed for suitable three-phase circuit arrangements.

What residual currents can the DDA203 AC-63/0.5 detect?

As a Type AC device, it is designed to respond to sinusoidal alternating residual currents.

Trusted ABB Circuit Protection

ABB DDA200 residual current device blocks provide modular earth-fault protection for electrical distribution systems, combining with compatible ABB miniature circuit breakers to create coordinated protection for commercial and industrial installations.