ABB DDA202 AC S-63/0.5 is a 2-pole selective Type AC residual current device block rated at 63 A with 500 mA sensitivity, 5 kA surge-current resistance and provision for remote tripping.
£115.75
The ABB DDA202 AC S-63/0.5 is a 2-pole selective Type AC residual current device (RCD) block designed for assembly with compatible ABB S200 series miniature circuit breakers. Part of the ABB DDA200 RCD series, it combines a 63 A rated current with a 500 mA rated residual current for commercial and industrial electrical distribution systems.
Its Type AC selective (S) characteristic responds to sinusoidal alternating earth fault currents with an intentional tripping delay. This delay enables residual-current selectivity with suitable downstream instantaneous devices, helping a local downstream fault to be disconnected without unnecessarily interrupting unaffected upstream circuits.
The DDA202 AC S-63/0.5 also provides 5 kA surge-current resistance and is supplied with additional terminals for remote tripping. Its 500 mA residual-current rating is intended for earth leakage and installation protection rather than the additional personal protection associated with 30 mA devices.
Selective residual-current protection is particularly useful in installations containing multiple RCD protection levels. The intentional operating delay of the ABB DDA202 AC S-63/0.5 enables coordination with suitable downstream instantaneous devices, allowing a downstream RCD to disconnect a local earth fault before the upstream selective device operates.
The DDA202 AC S-63/0.5 responds to sinusoidal alternating earth fault currents and provides 5 kA surge-current resistance. Its 500 mA sensitivity makes it suitable for earth leakage and installation protection in coordinated commercial and industrial distribution systems rather than additional personal protection applications requiring 30 mA sensitivity.
| Series | DDA200 |
|---|---|
| SKU | DDA202ACS630.5 |
| Order code | 2CSB202901R4630 |
| EAN | 8012542809708 |
| Product type | Selective residual current device (RCD) block |
| Residual-current type | Type AC |
| Selective characteristic | S type |
| Number of poles | 2 |
| Rated current | 63 A |
| Rated residual current | 500 mA |
| Nominal voltage | 230 V AC |
| Residual-current waveform | Sinusoidal AC |
| Tripping characteristic | Intentional time delay for selective coordination |
| Surge-current resistance | 5 kA (8/20 waveform) |
| Standard | IEC/EN 61009 Annex G |
| Application | Commercial and industrial installations |
| Compatible circuit breakers | ABB S200 series MCBs |
| Remote tripping | Additional terminals provided |
| Weight | approx. 0.20 kg |
The DDA202 AC S-63/0.5 is a 2-pole selective Type AC RCD block designed for commercial and industrial installations requiring 500 mA earth leakage protection and selective coordination with suitable downstream instantaneous residual-current devices.
The S designation means selective. The RCD block incorporates an intentional tripping delay that allows suitable downstream instantaneous residual-current devices to operate first when a local earth fault occurs.
The device has a rated residual current of 500 mA. This rating is intended for earth leakage and installation protection rather than the additional personal protection normally associated with 30 mA RCDs.
Type AC means the DDA202 AC S-63/0.5 is designed to respond to sinusoidal alternating residual currents. The suitability of Type AC protection should always be matched to the characteristics of the connected loads and applicable installation requirements.
Yes. ABB specifies that DDA200 AC S selective RCD blocks are supplied with additional terminals for remote tripping, allowing the protective device to be incorporated into suitable remote-disconnection arrangements.
ABB DDA200 AC S residual current device blocks provide selective Type AC earth leakage protection for commercial and industrial installations, combining intentional tripping delay, 5 kA surge-current resistance and remote-tripping provision with modular integration into ABB circuit protection systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.