2CSB202592R1400 ABB DDA202 B-40/0.03 AP-R RCD Block 2P 40 A 30 mA Type B

2CSB202592R1400 ABB DDA202 B-40/0.03 AP-R RCD Block 2P 40 A 30 mA Type B

ABB DDA202 B-40/0.03 AP-R is a 2-pole Type B high-immunity residual current device block rated at 40 A with 30 mA residual current sensitivity for demanding low-voltage installations containing electronic equipment.

SKU: 2CSB202592R1400Alt SKU: DDA202B400.03APRMPN: 2CSB202592R1400
Price
List Price £893.97 ex VAT
Your Price (ex VAT) Save 35%
£581.08 35% OFF
You save £312.89 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £581.08
Trade pricing is personalised to your account

Manufacturer Lead Time

£581.08

Why Choose the ABB DDA202 B-40/0.03 AP-R RCD Block?

The ABB DDA202 B-40/0.03 AP-R, order code 2CSB202592R1400, is a 2-pole Type B residual current device (RCD) block designed for assembly with compatible ABB miniature circuit breakers to provide comprehensive residual current protection in low-voltage electrical installations. As part of the ABB DDA200 RCD series, it is particularly suited to commercial and industrial installations containing electronic equipment.

This Type B RCD block has a 40 A rated current and a highly sensitive 30 mA rated residual operating current. Type B protection responds to a broad range of residual current waveforms, including sinusoidal AC, pulsating DC and smooth DC residual currents, making it suitable for applications where power electronics can generate residual currents that require all-current-sensitive protection.

The AP-R high-immunity characteristic incorporates a short time delay to improve resistance to unwanted tripping caused by transient disturbances. With a 230 V rated voltage, 50–60 Hz rated frequency and maximum surge-current withstand of 3 kA, the DDA202 B-40/0.03 AP-R provides robust residual current protection for demanding electrical systems.

Key Advantages

  • Advanced 2-pole Type B RCD block for all-current-sensitive residual current protection.
  • 40 A rated current for low-voltage electrical circuits.
  • Highly sensitive 30 mA rated residual operating current.
  • Detection of AC, pulsating DC and smooth DC residual currents.
  • AP-R high-immunity characteristic helps reduce unwanted tripping.
  • 3 kA maximum surge-current withstand for improved immunity to transient events.
  • Designed for assembly with compatible ABB S200 family miniature circuit breakers.

Key Features

  • ABB DDA200 RCD series.
  • 2-pole configuration.
  • 40 A rated current.
  • 30 mA rated residual current.
  • Type B residual current detection.
  • AP-R high-immunity operating characteristic.
  • 230 V rated voltage.
  • 50–60 Hz rated frequency.
  • 3 kA maximum surge current.
  • 10 ms short-time delay.
  • IP2X degree of protection.
  • Designed for demanding applications containing electronic equipment.

Type B AP-R Protection for Electronic Equipment

Type B residual current protection is designed to detect a broad range of earth fault currents, including sinusoidal alternating, pulsating DC and smooth DC residual currents. This makes the ABB DDA202 B-40/0.03 AP-R particularly suitable for installations containing power electronics and other equipment capable of generating residual current waveforms that cannot be fully addressed by conventional Type AC or Type A protection.

The AP-R high-immunity characteristic provides enhanced resistance to transient disturbances, with a short-time delay of approximately 10 ms and surge-current withstand of 3 kA. When assembled with a compatible ABB miniature circuit breaker, the RCD block provides residual current protection while the associated MCB provides overcurrent and short-circuit protection.

Typical Applications

  • Commercial and industrial electrical distribution systems.
  • Circuits requiring 30 mA Type B residual current protection.
  • Installations containing electronic power equipment.
  • Equipment capable of producing smooth DC residual currents.
  • Applications where enhanced immunity to unwanted RCD tripping is required.
  • Electrical protection assemblies using compatible ABB S200 family miniature circuit breakers.

Technical Specifications

Series DDA200
Order code 2CSB202592R1400
EAN 8012542515128
Product group DDA200 RCD
Product type Residual current device block
Residual current type Type B
Operating characteristic AP-R high immunity
Rated current 40 A
Rated residual current 30 mA
Rated voltage 230 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Number of poles 2
Frequency 50–60 Hz
Maximum surge current 3 kA
Short-time delay 10 ms
Power loss 3.2 W
Electrical endurance 10,000 cycles
Protection rating IP2X
Connecting capacity 25 mm² rigid or flexible conductor
Operating ambient temperature -25 to +55 °C
Standards IEC/EN 61009 Annex G and IEC/EN 62423
Compatible MCB families ABB S200 L, S200, S200 M and S200 P
Dimensions (W × H × D) 105 × 93 × 76 mm
Weight approx. 0.29 kg

Frequently Asked Questions

What is the ABB DDA202 B-40/0.03 AP-R used for?

The ABB DDA202 B-40/0.03 AP-R is a Type B RCD block designed for assembly with a compatible ABB miniature circuit breaker to provide residual current protection in installations containing electronic equipment and other loads capable of producing AC, pulsating DC or smooth DC residual currents.

What is the rated current of the ABB DDA202 B-40/0.03 AP-R?

The DDA202 B-40/0.03 AP-R has a rated current of 40 A.

What is the residual current sensitivity of this RCD block?

The device has a rated residual operating current of 30 mA.

What does Type B AP-R mean on this ABB RCD block?

Type B indicates all-current-sensitive residual current detection, including AC, pulsating DC and smooth DC residual currents, while AP-R identifies ABB's high-immunity characteristic designed to improve resistance to unwanted tripping caused by transient disturbances.

Which miniature circuit breakers are compatible with the ABB DDA202 B-40/0.03 AP-R?

The DDA200 RCD block can be assembled with compatible ABB S200 L, S200, S200 M and S200 P miniature circuit breakers to create a combined residual current, overcurrent and short-circuit protection arrangement.

Trusted ABB Circuit Protection Technology

ABB DDA200 Type B AP-R RCD blocks provide advanced all-current-sensitive residual current protection with enhanced immunity to transient disturbances for demanding commercial and industrial electrical installations.