ABB DDA202 B-25/0.03 AP-R is a 2-pole Type B residual current device block rated at 25 A with 30 mA sensitivity for detecting AC, pulsating DC and smooth DC residual currents.

SKU: 2CSB202592R1250Alt SKU: DDA202B250.03APRMPN: 2CSB202592R1250
Price
List Price £756.34 ex VAT
Your Price (ex VAT) Save 35%
£491.62 35% OFF
You save £264.72 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £491.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£491.62

Why Choose the ABB DDA202 B-25/0.03 AP-R RCD Block?

The ABB DDA202 B-25/0.03 AP-R is a 2-pole Type B residual current device (RCD) block designed for applications where complex residual-current waveforms can occur. Part of the ABB DDA200 RCD series, it combines a 25 A rated current with sensitive 30 mA residual-current protection and ABB's AP-R enhanced immunity concept for dependable circuit protection.

Its Type B residual-current characteristic extends detection beyond conventional Type AC and Type A protection, responding to sinusoidal AC, pulsating DC and smooth DC residual currents. This makes the DDA202 B-25/0.03 AP-R particularly relevant to circuits containing power electronics, converters and other equipment capable of generating DC or mixed-frequency earth leakage currents.

Designed for assembly with compatible ABB miniature circuit breakers, the DDA202 B-25/0.03 AP-R provides residual-current protection while the associated circuit breaker supplies overload and short-circuit protection. Its 30 mA sensitivity supports additional protection against electric shock, while the modular construction enables compact integration into electrical distribution equipment.

Key Advantages

  • Type B residual-current protection for AC, pulsating DC and smooth DC residual currents.
  • 30 mA rated residual current for sensitive earth leakage detection and additional protection against electric shock.
  • AP-R characteristic for enhanced immunity to transient disturbances and unwanted tripping.
  • 25 A rated current for compatible electrical distribution circuits.
  • 2-pole configuration for two-conductor circuit protection arrangements.
  • Well suited to installations containing power electronic and converter-based loads.

Key Features

  • ABB DDA200 RCD series.
  • 2-pole Type B RCD block.
  • AP-R enhanced-immunity characteristic.
  • 25 A rated current.
  • 30 mA rated residual current.
  • Detection of AC, pulsating DC and smooth DC residual currents.
  • Suitable for circuits incorporating electronic power conversion equipment.
  • Modular design for combination with compatible ABB miniature circuit breakers.
  • Designed to combine residual-current protection with associated overload and short-circuit protection.

Type B Protection for Power Electronic Loads

Electrical equipment incorporating rectifiers, inverters, variable-speed drives and other power electronics can generate residual-current waveforms that conventional Type AC or Type A devices are not designed to detect in full. Type B residual-current protection extends detection to smooth DC residual currents as well as AC and pulsating DC leakage, making it appropriate where these more complex fault currents can occur.

The ABB DDA202 B-25/0.03 AP-R combines this broad residual-current detection capability with 30 mA sensitivity and enhanced immunity to transient disturbances. When assembled with a compatible ABB miniature circuit breaker, it forms a coordinated protective arrangement providing residual-current, overload and short-circuit protection.

Typical Applications

  • Commercial and industrial electrical distribution systems.
  • Circuits incorporating power electronic equipment.
  • Variable-speed drive and frequency-converter applications where Type B protection is required.
  • Power supplies and converter-based electrical equipment.
  • Circuits where smooth DC residual currents may occur.
  • Applications requiring 30 mA Type B residual-current protection.
  • Electrical control panels and modular distribution equipment.
  • Installations where improved immunity to transient disturbances is beneficial.

Technical Specifications

Series DDA200
SKU DDA202B250.03APR
Order code 2CSB202592R1250
Product type Residual current device (RCD) block
Residual-current type Type B
Operating characteristic AP-R enhanced immunity
Number of poles 2
Rated current 25 A
Rated residual current 30 mA
Residual-current detection AC, pulsating DC and smooth DC
Protection function Residual-current protection
Associated protection Overload and short-circuit protection provided by compatible circuit breaker
Installation type Modular electrical distribution equipment

Frequently Asked Questions

What is the ABB DDA202 B-25/0.03 AP-R used for?

The DDA202 B-25/0.03 AP-R is a 2-pole Type B RCD block designed for residual-current protection in circuits where AC, pulsating DC or smooth DC earth leakage currents can occur, including installations containing power electronic equipment.

What does Type B mean on the DDA202 B-25/0.03 AP-R?

Type B provides residual-current detection for sinusoidal AC, pulsating DC and smooth DC residual currents, extending protection beyond the residual-current waveforms covered by Type AC and Type A devices.

What residual-current sensitivity does the DDA202 B-25/0.03 AP-R provide?

The device has a rated residual current of 30 mA, providing sensitive earth leakage detection and additional protection against electric shock.

Why is Type B protection used with power electronic equipment?

Power electronic equipment can produce smooth DC and other complex residual-current waveforms. A Type B RCD is designed to detect these currents as well as conventional AC and pulsating DC residual currents, making it suitable where the connected equipment requires Type B protection.

Is the DDA202 B-25/0.03 AP-R a complete RCBO on its own?

No. The DDA202 B-25/0.03 AP-R is an RCD block designed for assembly with a compatible ABB miniature circuit breaker. The RCD block provides residual-current protection, while the associated circuit breaker provides overload and short-circuit protection.

Trusted ABB Type B Circuit Protection

ABB DDA200 Type B residual current device blocks provide advanced residual-current protection for installations containing modern power electronics, supporting detection of AC, pulsating DC and smooth DC earth leakage currents in coordinated modular circuit protection assemblies.