ABB DDA202A400.03APR DDA202 A-40/0.03 AP-R is a 2-pole 40 A 30 mA Type A residual current device block with enhanced immunity to transient disturbances for use with compatible ABB miniature circuit breakers.
£104.57
The ABB DDA202A400.03APR, manufacturer type DDA202 A-40/0.03 AP-R, is a 2-pole Type A AP-R residual current device (RCD) block designed for combination with compatible ABB miniature circuit breakers. Part of the ABB DDA200 RCD series, it provides residual-current protection with enhanced resistance to unwanted tripping in electrical installations affected by transient disturbances.
The DDA202 A-40/0.03 AP-R is designed to detect sinusoidal alternating and pulsating DC residual currents. ABB's AP-R characteristic provides increased immunity to transient currents together with short-delay operation, helping improve continuity of service compared with conventional instantaneous residual-current protection in applications susceptible to nuisance tripping.
With a rated current of 40 A, a rated residual operating current of 30 mA and a 2-pole configuration, the DDA202A400.03APR is suited to residential, commercial and industrial circuits requiring sensitive Type A residual-current protection. Its modular construction allows combination with compatible ABB miniature circuit breakers for coordinated residual-current and overcurrent protection.
Residual current protection monitors the balance of current flowing through a circuit and operates when leakage to earth exceeds the specified threshold. The ABB DDA202 A-40/0.03 AP-R combines 30 mA sensitivity with Type A detection, allowing it to respond to sinusoidal alternating residual currents and pulsating DC residual currents.
The AP-R characteristic is designed for installations where switching operations, electronic loads or transient disturbances can lead to unwanted operation of conventional instantaneous RCDs. Its enhanced immunity and short-delay behaviour help maintain service continuity while providing dependable residual-current protection.
| Series | DDA200 |
|---|---|
| SKU | DDA202A400.03APR |
| ABB order code | 2CSB202401R1400 |
| Product type | Residual current device block / RCD block |
| Residual-current type | Type A |
| Operating characteristic | AP-R |
| Number of poles | 2 |
| Rated current | 40 A |
| Rated residual operating current | 30 mA |
| Rated voltage | 230/400 V AC |
| Rated frequency | 50–60 Hz |
| Rated insulation voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Protection rating | IP2X |
| Standard | IEC/EN 61009 Annex G |
The ABB DDA202A400.03APR is a Type A AP-R RCD block designed for combination with compatible ABB miniature circuit breakers to provide sensitive residual-current protection with enhanced immunity to unwanted tripping.
The ABB DDA202 A-40/0.03 AP-R has a rated current of 40 A.
The DDA202 A-40/0.03 AP-R has a rated residual operating current of 30 mA.
The AP-R characteristic provides enhanced immunity to transient disturbances and short-delay operation, helping reduce unwanted tripping compared with conventional instantaneous residual-current devices.
As a Type A device, it is designed to respond to sinusoidal alternating residual currents and pulsating DC residual currents.
ABB DDA200 AP-R residual current device blocks combine Type A earth-fault detection with enhanced resistance to transient disturbances, providing dependable protection where continuity of service and reduced nuisance tripping are important.