ABB S202M-B32UC is a 32 A two-pole Type B miniature circuit breaker with a 10 kA short-circuit rating, designed for reliable overload and short-circuit protection in demanding industrial and traction-related electrical circuits.

SKU: 2CDS272061R0325Alt SKU: S202MB32UCMPN: 2CDS272061R0325
Price
List Price £201.96 ex VAT
Your Price (ex VAT) Save 25%
£151.47 25% OFF
You save £50.49 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £151.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£151.47

Why Choose the ABB S202M-B32UC Miniature Circuit Breaker?

The ABB S202M-B32UC is a compact two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overload and short-circuit conditions. With ABB order code 2CDS272061R0325, this device forms part of ABB's specialist DC / traction miniature circuit breaker portfolio for demanding industrial and transportation electrical systems.

Featuring a 32 A rated current, Type B tripping characteristic and 10 kA short-circuit rating, the S202M-B32UC provides dependable overcurrent protection for circuits with relatively low inrush currents. The Type B characteristic provides sensitive magnetic operation, making it suitable for resistive loads, distribution circuits and other applications where high starting currents are not normally expected.

Its compact 2-pole modular configuration enables coordinated protection and switching of two conductors, making the S202M-B32UC suitable for distribution assemblies, control panels, auxiliary power systems and traction-related installations where robust circuit protection is required.

Key Advantages

  • 32 A rated current for distribution, auxiliary and equipment circuits.
  • 2-pole configuration for coordinated protection of two conductors.
  • Type B tripping characteristic suitable for circuits with relatively low inrush currents.
  • High 10 kA short-circuit rating.
  • Provides overload and short-circuit protection for connected conductors and equipment.
  • Compact modular format for integration into electrical distribution and control assemblies.
  • Suitable for industrial distribution, auxiliary power and equipment protection circuits.
  • Part of ABB's specialist DC / traction MCB portfolio.

Key Features

  • ABB S202M miniature circuit breaker.
  • 32 A nominal current.
  • 2-pole configuration.
  • Type B characteristic.
  • 10 kA short-circuit rating.
  • Overload and short-circuit circuit protection.
  • Compact modular construction for electrical panels.
  • Suitable for demanding industrial and traction-related electrical systems.
  • ABB order code 2CDS272061R0325.

Reliable Circuit Protection for Industrial and Traction Systems

Miniature circuit breakers such as the ABB S202M-B32UC automatically interrupt excessive current caused by overload or short-circuit conditions. This helps protect conductors and connected electrical equipment from damaging overcurrents while providing resettable circuit protection once the cause of a fault has been identified and corrected.

The Type B characteristic provides relatively sensitive instantaneous operation and is well suited to circuits where significant starting currents are not normally present. Combined with its 2-pole configuration and 32 A rating, the S202M-B32UC provides practical protection for distribution, auxiliary and equipment circuits in demanding electrical installations.

Typical Applications

  • Industrial electrical distribution circuits.
  • Traction and transportation electrical systems.
  • Auxiliary power circuits.
  • Industrial automation and control panels.
  • Resistive and low-inrush electrical loads.
  • Electrical distribution and protection assemblies.
  • Commercial and industrial electrical installations.

Technical Specifications

Series S202M
ABB order code 2CDS272061R0325
Product type Miniature circuit breaker (MCB)
Rated current 32 A
Number of poles 2
Tripping characteristic B
Short-circuit rating 10 kA
Product group DC / Traction MCB

Frequently Asked Questions

What is the ABB S202M-B32UC used for?

The ABB S202M-B32UC is a two-pole miniature circuit breaker designed to protect electrical circuits against overload and short-circuit conditions in industrial, distribution and traction-related applications.

What is the current rating of the S202M-B32UC?

The S202M-B32UC has a rated current of 32 A, making it suitable for a range of distribution, auxiliary power and equipment circuits.

What does the Type B characteristic mean?

The Type B tripping characteristic provides relatively sensitive magnetic operation and is generally suited to circuits with low inrush currents, including resistive, distribution and auxiliary loads.

What is the short-circuit rating of the ABB S202M-B32UC?

The S202M-B32UC has a 10 kA short-circuit rating, providing substantial fault-current interruption capability for suitable electrical installations.

How many poles does the S202M-B32UC have?

The S202M-B32UC is a two-pole (2P) miniature circuit breaker, enabling coordinated protection and switching of two conductors.

Trusted ABB Circuit Protection

ABB DC and traction miniature circuit breakers provide dependable overload and short-circuit protection for demanding electrical systems, combining compact modular construction with application-specific tripping characteristics and robust interruption capability.