2CDS271565R0517 ABB S201MTR-K25 DC MCB 10kA 1P Type K 25A

2CDS271565R0517 ABB S201MTR-K25 DC MCB 10kA 1P Type K 25A

ABB S201MTR-K25 DC is a 25 A single-pole Type K DC miniature circuit breaker with a 10 kA short-circuit breaking capacity for overload and short-circuit protection in railway, rolling stock and traction-related electrical installations.

SKU: 2CDS271565R0517Alt SKU: S201MTRK25DCMPN: 2CDS271565R0517
Price
List Price £164.30 ex VAT
Your Price (ex VAT) Save 25%
£123.23 25% OFF
You save £41.08 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £123.23
Trade pricing is personalised to your account

Manufacturer Lead Time

£123.23

Why Choose the ABB S201MTR-K25 DC Miniature Circuit Breaker?

The ABB S201MTR-K25 DC is a specialised single-pole DC miniature circuit breaker (MCB) designed to protect electrical circuits against overload and short-circuit conditions. As part of the ABB S200 MTR DC series, it is developed for demanding railway, rolling stock and traction-related DC electrical applications where dependable circuit protection is essential.

Featuring a Type K tripping characteristic, the S201MTR-K25 DC is particularly suited to circuits supplying equipment with functional peak or inrush currents. This characteristic makes it a practical choice for protecting motors, transformers, solenoids and other inductive loads while providing reliable overload and short-circuit protection.

With a rated current of 25 A, a single-pole configuration and a short-circuit breaking capacity of 10 kA, the S201MTR-K25 DC provides robust protection for DC auxiliary, equipment and distribution circuits. ABB order code 2CDS271565R0517 identifies this specific 25 A Type K version of the S200 MTR DC range.

Key Advantages

  • Purpose-designed DC miniature circuit breaker for railway and traction applications.
  • 25 A rated current suitable for auxiliary, equipment and distribution circuits.
  • 10 kA short-circuit breaking capacity for robust fault protection.
  • Type K tripping characteristic suitable for loads with functional peak and inrush currents.
  • Well suited to motors, transformers, solenoids and other inductive DC loads.
  • Provides dependable overload and short-circuit circuit protection.
  • Compact single-pole construction helps minimise panel space requirements.
  • Designed for railway, rolling stock and traction-related DC applications.

Key Features

  • ABB S200 MTR DC miniature circuit breaker series.
  • 25 A rated current.
  • 1-pole configuration.
  • Type K tripping characteristic.
  • 10 kA short-circuit breaking capacity.
  • Dedicated design for DC railway and rolling stock applications.
  • Suitable for circuits with elevated starting and operational inrush currents.
  • Overload protection for conductors and connected equipment.
  • Short-circuit protection for rapid isolation of electrical faults.
  • Compact modular construction for space-conscious electrical assemblies.
  • Suitable for railway auxiliary and equipment circuits.
  • Designed for integration into traction electrical distribution systems.

Reliable Protection for Inductive DC Loads

Miniature circuit breakers such as the ABB S201MTR-K25 DC protect cables, conductors and connected equipment by interrupting excessive current caused by overload or short-circuit conditions. The S200 MTR DC range is intended for railway and traction applications where dependable DC circuit protection is required in on-board electrical and distribution systems.

The S201MTR-K25 DC's Type K characteristic makes it particularly suitable for circuits containing motors, transformers, solenoids and other inductive equipment that can produce temporary current peaks during normal operation. Combined with its 25 A rated current and 10 kA short-circuit breaking capacity, it provides a robust protection solution for DC equipment and auxiliary circuits in rolling stock and traction systems.

Typical Applications

  • Railway and rolling stock electrical installations.
  • Train auxiliary DC circuits.
  • Motor and actuator circuits.
  • Transformer and solenoid circuits.
  • On-board DC electrical distribution systems.
  • Rail vehicle electrical cabinets and panels.
  • Traction-related auxiliary equipment.
  • DC circuits with inductive loads and operational inrush currents.

Technical Specifications

Series S200 MTR DC
ABB order code 2CDS271565R0517
Product type DC miniature circuit breaker (MCB)
Product group DC / Traction MCB
Rated current 25 A
Number of poles 1
Tripping characteristic Type K
Short-circuit breaking capacity 10 kA
Voltage type DC
Protection function Overload and short-circuit protection
Application Railway / rolling stock and traction-related DC installations

Frequently Asked Questions

What is the ABB S201MTR-K25 DC used for?

The ABB S201MTR-K25 DC is a DC miniature circuit breaker designed to protect circuits against overload and short-circuit conditions, particularly in railway, rolling stock and traction-related electrical installations.

What is the rated current of the S201MTR-K25 DC?

The S201MTR-K25 DC has a rated current of 25 A and uses a single-pole configuration.

What does the Type K characteristic mean?

The Type K tripping characteristic is suited to circuits supplying equipment with functional peak or inrush currents, including motors, transformers and solenoids, while providing dependable overload and short-circuit protection.

What breaking capacity does the ABB S201MTR-K25 DC provide?

The S201MTR-K25 DC provides a 10 kA short-circuit breaking capacity for robust protection against electrical faults.

What is the ABB order code for the S201MTR-K25 DC?

The ABB order code for the S201MTR-K25 DC 25 A single-pole Type K MCB is 2CDS271565R0517.

Trusted Protection for Railway Electrical Systems

ABB S200 MTR DC miniature circuit breakers provide dependable overload and short-circuit protection for railway and traction electrical systems, combining dedicated DC circuit protection with characteristics suited to demanding rolling stock auxiliary and distribution applications.