2CDS271527R0527 ABB SU201DC-K30 30 A 1P Type K DC Miniature Circuit Breaker 14 kA

2CDS271527R0527 ABB SU201DC-K30 30 A 1P Type K DC Miniature Circuit Breaker 14 kA

ABB SU201DC-K30 is a 30 A single-pole K-characteristic SU200DC miniature circuit breaker with a 14 kA UL 489 short-circuit current rating for DC motor, transformer and auxiliary circuit protection.

SKU: 2CDS271527R0527Alt SKU: SU201DCK30MPN: 2CDS271527R0527
Price
List Price £87.09 ex VAT
Your Price (ex VAT) Save 25%
£65.32 25% OFF
You save £21.77 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £65.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£65.32

Why Choose the ABB SU201DC-K30 Miniature Circuit Breaker?

The ABB SU201DC-K30 is a specialised single-pole DC miniature circuit breaker (MCB) designed for overload and short-circuit protection of motor, transformer and auxiliary circuits. Part of the ABB SU200DC series, this model combines a 30 A rated current, K tripping characteristic and a high short-circuit current rating for demanding commercial and industrial DC applications.

The K characteristic is designed for loads that can produce substantial functional peak currents during normal operation. ABB specifies the SU200DC K-characteristic range for motor, transformer and auxiliary circuits, with tolerance of functional peak currents up to 10 × In, depending on the application, helping reduce unwanted tripping while maintaining effective cable and line protection.

The SU201DC-K30 provides a 14 kA SCCR according to UL 489 and is designed for DC operation up to 125 V DC. Its compact single-pole format, DIN-rail mounting and compliance with UL 489 and CSA 22.2 No. 5 make it a robust choice for DC distribution, machinery and industrial control equipment.

Key Advantages

  • Reliable overload and short-circuit protection for DC circuits.
  • 30 A rated current for higher-current power and auxiliary applications.
  • K tripping characteristic optimised for loads with functional peak and starting currents.
  • High 14 kA SCCR according to UL 489.
  • Suitable for DC operation up to 125 V DC.
  • Designed specifically for motor, transformer and auxiliary circuits.
  • Compact single-pole, one-module construction.
  • Complies with UL 489 and CSA 22.2 No. 5.

Key Features

  • ABB SU200DC series miniature circuit breaker.
  • 30 A rated current.
  • K tripping characteristic.
  • 1-pole configuration with one protected pole.
  • 14 kA short-circuit current rating according to UL 489.
  • DC operation up to 125 V DC.
  • 250 V rated insulation voltage (Ui).
  • 3 kV rated impulse withstand voltage (Uimp).
  • Energy limiting class 3.
  • Overvoltage category III.
  • Pollution degree 3.
  • Operating ambient temperature range of -20 to +55 °C.
  • Compact 1-module width for DIN-rail installations.
  • Polarity must be observed when installed in DC circuits.

Reliable Protection for Motors, Transformers and DC Auxiliary Circuits

The ABB SU201DC-K30 protects cables and connected equipment against excessive current resulting from overload and short-circuit conditions. Its K characteristic is particularly useful where normal energisation produces higher current peaks, allowing the breaker to accommodate appropriate functional inrush while continuing to provide dependable protection for the circuit.

ABB specifies the SU200DC K-characteristic range for commercial and industrial motor, transformer and auxiliary circuits. Combined with a 14 kA UL 489 SCCR, compact modular dimensions and support for conductors up to 35 mm², the SU201DC-K30 is well suited to robust DC distribution and industrial control assemblies.

Typical Applications

  • DC motor circuits.
  • Transformer circuits.
  • Industrial DC auxiliary circuits.
  • Machine and automation control panels.
  • Commercial and industrial DC distribution systems.
  • Solenoids and other inductive DC loads.
  • Circuits with elevated functional starting or peak currents.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series SU200DC
ABB order code 2CDS271527R0527
Product type DC miniature circuit breaker (MCB)
Rated current 30 A
Number of poles 1
Number of protected poles 1
Tripping characteristic K
DC operating voltage Up to 125 V DC
Short-circuit current rating 14 kA SCCR according to UL 489
Rated insulation voltage (Ui) 250 V
Rated impulse withstand voltage (Uimp) 3 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 3
Width 1 modular unit
Mounting depth 69 mm
Operating ambient temperature -20 to +55 °C
Solid conductor capacity 0.75–35 mm²
Stranded conductor capacity 0.75–25 mm²
Power loss 3.1 W
Standards UL 489, CSA 22.2 No. 5
Product group DC / Traction MCB

Frequently Asked Questions

What is the ABB SU201DC-K30 used for?

The ABB SU201DC-K30 provides overload and short-circuit protection for DC circuits and is specifically suited to motor, transformer and auxiliary applications in commercial and industrial systems.

What is the rated current of the SU201DC-K30?

The SU201DC-K30 has a rated current of 30 A and uses a single-pole configuration with one protected pole.

What does the K characteristic mean on the SU201DC-K30?

The K characteristic is intended for loads with elevated functional starting or peak currents, including motors and transformers. ABB specifies tolerance of functional peak currents up to 10 × In for the SU200DC K range, depending on the application.

What is the short-circuit rating of the ABB SU201DC-K30?

The SU201DC-K30 has a 14 kA short-circuit current rating (SCCR) according to UL 489.

What DC voltage and standards apply to the SU201DC-K30?

The SU201DC-K30 is designed for operation up to 125 V DC and complies with UL 489 and CSA 22.2 No. 5. The specified device polarity must be observed when installing it in a DC circuit.

Trusted DC Circuit Protection from ABB

ABB SU200DC K-characteristic miniature circuit breakers provide robust branch-circuit protection for commercial and industrial DC systems, combining high short-circuit capability with characteristics suited to motors, transformers and auxiliary loads with functional peak currents.