2CDS271527R0278 ABB SU201DC-Z2 MCB 14kA 1P Type Z 2A

2CDS271527R0278 ABB SU201DC-Z2 MCB 14kA 1P Type Z 2A

ABB SU201DC-Z2 is a 2 A Type Z single-pole DC miniature circuit breaker with a 14 kA short-circuit current rating according to UL 489, designed for reliable overload and short-circuit protection of electronic and low-current DC circuits.

SKU: 2CDS271527R0278Alt SKU: SU201DCZ2MPN: 2CDS271527R0278
Price
List Price £89.93 ex VAT
Your Price (ex VAT) Save 25%
£67.45 25% OFF
You save £22.48 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £67.45
Trade pricing is personalised to your account

Manufacturer Lead Time

£67.45

Why Choose the ABB SU201DC-Z2 Miniature Circuit Breaker?

The ABB SU201DC-Z2 is a specialised DC miniature circuit breaker (MCB) designed to protect cables, conductors and electronic circuits against overloads and short circuits. Part of the ABB SU200DC series, this single-pole circuit breaker is designed for reliable protection and control in commercial and industrial DC electrical applications.

The SU201DC-Z2 features a Type Z tripping characteristic, a rated current of 2 A and a 14 kA short-circuit current rating (SCCR) according to UL 489. The sensitive Z characteristic makes it particularly suitable for electronic and other circuits where protection against relatively low overcurrents is important.

With its single-pole configuration and suitability for DC circuits up to 125 V DC, the SU201DC-Z2 provides a compact solution for low-current DC protection. The SU200DC range complies with UL 489 and CSA C22.2 No. 5 and supports direct connection of conductors up to 35 mm².

Key Advantages

  • Purpose-designed miniature circuit breaker for DC applications.
  • 2 A rated current for reliable protection of low-current circuits.
  • Type Z tripping characteristic suited to sensitive electronic circuits.
  • 14 kA SCCR according to UL 489.
  • Suitable for DC applications up to 125 V DC.
  • Single-pole configuration for compact circuit protection.

Key Features

  • ABB SU200DC miniature circuit breaker series.
  • 2 A rated current.
  • Type Z tripping characteristic.
  • 14 kA short-circuit current rating (SCCR).
  • 1-pole configuration.
  • Protection and control of electronic circuits against overloads and short circuits.
  • Suitable for DC circuits up to 125 V DC.
  • Designed for commercial and industrial applications.
  • Compliant with UL 489.
  • Compliant with CSA C22.2 No. 5.
  • Direct connection of conductors up to 35 mm².
  • Polarity must be observed when used in DC circuits.

Reliable Circuit Protection for DC Electrical Systems

Miniature circuit breakers such as the ABB SU201DC-Z2 automatically interrupt a circuit when excessive current results from an overload or short circuit. This helps protect cables, conductors and connected electronic equipment while allowing the circuit breaker to be reset after the electrical fault has been identified and corrected.

The ABB SU200DC Z-characteristic range is particularly suited to the protection and control of electronic circuits against light, sustained overloads and short circuits. Its combination of sensitive Type Z tripping behaviour, a 14 kA SCCR and compliance with UL 489 and CSA C22.2 No. 5 makes the SU201DC-Z2 a practical choice for demanding low-current DC applications.

Typical Applications

  • DC electrical distribution systems.
  • Electronic circuit protection.
  • Industrial control and automation circuits.
  • Low-current auxiliary circuits.
  • Commercial and industrial DC installations.
  • Circuits requiring sensitive Type Z overload and short-circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series SU200DC
ABB order code 2CDS271527R0278
Product type Miniature circuit breaker (MCB)
Product group DC / Traction MCB
Rated current 2 A
Tripping characteristic Type Z
Short-circuit current rating (SCCR) 14 kA
Number of poles 1
Maximum DC voltage 125 V DC
Standards UL 489, CSA C22.2 No. 5
Maximum direct conductor cross-section 35 mm²
Installation depth 69 mm
Power loss 1.3 W
Pollution degree 3
EAN 4053546175905

Frequently Asked Questions

What is the ABB SU201DC-Z2 used for?

The SU201DC-Z2 is a miniature circuit breaker designed to protect and control low-current DC electrical and electronic circuits against overloads and short circuits.

What is the rated current of the ABB SU201DC-Z2?

The SU201DC-Z2 has a rated current of 2 A.

What tripping characteristic does the SU201DC-Z2 have?

The circuit breaker has a Type Z tripping characteristic, providing sensitive overcurrent protection suitable for electronic and other low-current circuits.

What is the breaking capacity of the ABB SU201DC-Z2?

The SU201DC-Z2 has a 14 kA short-circuit current rating (SCCR) according to UL 489.

What is the ABB order code for the SU201DC-Z2?

The ABB order code for the SU201DC-Z2 is 2CDS271527R0278.

Trusted DC Circuit Protection from ABB

ABB SU200DC miniature circuit breakers provide dependable overload and short-circuit protection for demanding DC electrical systems, combining high short-circuit performance, application-specific tripping characteristics and a compact installation format.