2CDS271447R0467 ABB S201MTR-K16 16 A 1P Type K Miniature Circuit Breaker 10 kA DC

2CDS271447R0467 ABB S201MTR-K16 16 A 1P Type K Miniature Circuit Breaker 10 kA DC

ABB S201MTR-K16 is a 16 A single-pole K-characteristic S 200 MTR miniature circuit breaker with 10 kA DC breaking capacity, designed for reliable overload and short-circuit protection in railway, rolling-stock and demanding electrical applications.

SKU: 2CDS271447R0467Alt SKU: S201MTRK16MPN: 2CDS271447R0467
Price
List Price £144.99 ex VAT
Your Price (ex VAT) Save 25%
£108.74 25% OFF
You save £36.25 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £108.74
Trade pricing is personalised to your account

Manufacturer Lead Time

£108.74

Why Choose the ABB S201MTR-K16 Miniature Circuit Breaker?

The ABB S201MTR-K16 is a high-performance single-pole miniature circuit breaker (MCB) designed for reliable protection and control of electrical circuits against overloads and short circuits. Part of the specialised ABB S 200 MTR series, it is engineered for demanding railway and rolling-stock electrical installations, with dedicated ring-terminal connections and suitability for AC and DC applications.

Featuring a 16 A rated current and K tripping characteristic, the S201MTR-K16 is particularly suited to circuits where controlled tolerance of higher starting currents is required. Its specialised MTR construction supports secure ring-cable-lug connections, while the series is designed to meet the environmental and mechanical demands encountered in rolling-stock applications.

The S201MTR-K16 provides a DC ultimate short-circuit breaking capacity of 10 kA and an AC ultimate short-circuit breaking capacity of 15 kA according to IEC/EN 60947-2. ABB specifies the S 200 MTR range to hazard level R26/HL3 according to EN 45545 and Category 1, Class A/B for body-mounted equipment according to IEC 61373.

Key Advantages

  • Reliable overload and short-circuit protection for demanding electrical circuits.
  • 16 A rated current with K tripping characteristic.
  • Single-pole configuration for compact circuit protection.
  • 10 kA DC breaking capacity for dedicated DC applications.
  • Special ring-terminal connection designed for secure cable termination.
  • Designed for railway and rolling-stock applications.
  • Meets relevant IEC/EN railway fire and vibration requirements for the S 200 MTR series.

Key Features

  • ABB S 200 MTR series miniature circuit breaker.
  • 16 A rated current.
  • K tripping characteristic.
  • 1-pole configuration.
  • 10 kA DC ultimate short-circuit breaking capacity.
  • 15 kA AC ultimate short-circuit breaking capacity according to IEC/EN 60947-2.
  • Special terminals for ring cable lugs.
  • Suitable for AC and polarity-dependent DC circuit protection.
  • Hazard level R26/HL3 according to EN 45545.
  • Category 1, Class A/B body-mounted classification according to IEC 61373.

Reliable Circuit Protection for Railway Electrical Systems

Miniature circuit breakers protect electrical wiring and connected equipment by automatically interrupting current when an overload or short circuit occurs. The ABB S201MTR-K16 combines thermal and magnetic protection with a K characteristic suited to applications where equipment may produce higher transient starting currents during normal operation.

The S 200 MTR range is specifically configured for demanding transportation environments. Its ring-terminal connection system provides secure electrical termination, while compliance with applicable railway fire and vibration classifications makes the series particularly suitable for electrical distribution and auxiliary circuits in rolling stock. When used on DC circuits, the polarity dependency marked on the device must be observed.

Typical Applications

  • Railway and rolling-stock electrical systems.
  • DC auxiliary and control circuits.
  • Train electrical distribution panels.
  • Industrial control and automation circuits.
  • Circuits requiring secure ring-terminal cable connections.
  • Equipment with elevated starting or inrush currents suited to K-characteristic protection.

Technical Specifications

Series S 200 MTR
ABB order code 2CDS271447R0467
Product type Miniature circuit breaker (MCB)
Rated current 16 A
Number of poles 1
Tripping characteristic K
DC ultimate short-circuit breaking capacity 10 kA
AC ultimate short-circuit breaking capacity 15 kA
Standard IEC/EN 60947-2
Railway fire classification R26/HL3 according to EN 45545
Railway mounting classification Category 1, Class A/B (body mounted) according to IEC 61373
Connection type Special ring-terminal connection
Application AC and DC circuit protection
Weight 0.125 kg

Frequently Asked Questions

What is the ABB S201MTR-K16 used for?

The ABB S201MTR-K16 is used to protect electrical circuits against overloads and short circuits, particularly in railway, rolling-stock and other demanding AC or DC electrical installations.

What is the rated current of the S201MTR-K16?

The S201MTR-K16 has a rated current of 16 A and is a single-pole miniature circuit breaker.

What tripping characteristic does this circuit breaker use?

This model uses a K tripping characteristic, making it suitable for circuits where higher starting or inrush currents can occur during normal operation.

What is the breaking capacity of the ABB S201MTR-K16?

The S201MTR-K16 has a 10 kA DC ultimate short-circuit breaking capacity and a 15 kA AC ultimate short-circuit breaking capacity according to IEC/EN 60947-2.

Is the S201MTR-K16 suitable for railway applications?

Yes. The ABB S 200 MTR series is designed for rolling-stock applications and is specified to R26/HL3 according to EN 45545 and Category 1, Class A/B according to IEC 61373.