2CDS271446R0971 ABB S201MT-D1.6NA MCB 10kA 1P+N Type D 1.6A

2CDS271446R0971 ABB S201MT-D1.6NA MCB 10kA 1P+N Type D 1.6A

ABB S201MT-D1.6NA is a 1.6 A 1P+N Type D miniature circuit breaker with 10 kA breaking capacity, designed for reliable overload and short-circuit protection in railway, rolling-stock and traction electrical systems.

SKU: 2CDS271446R0971Alt SKU: S201MTD1.6NAMPN: 2CDS271446R0971
Price
List Price £158.29 ex VAT
Your Price (ex VAT) Save 25%
£118.72 25% OFF
You save £39.57 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £118.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£118.72

Why Choose the ABB S201MT-D1.6NA Miniature Circuit Breaker?

The ABB S201MT-D1.6NA is a specialist 1P+N miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short-circuits. Part of the ABB S200 MT series, it is intended for demanding railway, rolling-stock and traction electrical installations where dependable circuit protection and phase-and-neutral switching are required.

Featuring a 1.6 A rated current, Type D tripping characteristic and 10 kA breaking capacity, the S201MT-D1.6NA provides robust protection for low-current auxiliary, control and equipment circuits. The Type D characteristic is suited to appropriate loads with comparatively high short-duration starting or inrush currents, helping accommodate normal energisation peaks while retaining overload and short-circuit protection.

The 1P+N configuration combines overcurrent protection of the phase conductor with switching of the neutral conductor, allowing phase and neutral to be disconnected together. Its compact DIN-rail construction supports efficient integration into railway distribution boards, rolling-stock control assemblies and industrial electrical panels.

Key Advantages

  • 1.6 A rated current for dependable protection of low-current circuits.
  • 1P+N configuration combines phase protection with neutral switching.
  • Type D tripping characteristic suited to appropriate loads with comparatively high starting or inrush currents.
  • 10 kA breaking capacity provides robust short-circuit fault interruption.
  • Specialist S200 MT design for railway and traction applications.
  • Provides protection against both overloads and short-circuits.
  • DIN-rail construction supports efficient integration into compact control and distribution assemblies.

Key Features

  • ABB S200 MT miniature circuit breaker series.
  • 1P+N pole configuration.
  • 1.6 A rated current.
  • Type D tripping characteristic.
  • 10 kA short-circuit breaking capacity.
  • Protected phase pole with switched neutral.
  • Overload and short-circuit protection.
  • Suitable for appropriate low-current circuits with high short-duration inrush currents.
  • Compact modular construction for electrical panels.
  • Designed for demanding railway, rolling-stock and traction applications.

Reliable Protection for Low-Current High-Inrush Circuits

Miniature circuit breakers such as the ABB S201MT-D1.6NA automatically interrupt a circuit when excessive current caused by an overload or short-circuit occurs. This helps protect electrical conductors, connected equipment and distribution systems while providing a resettable protective solution that can be returned to service after the fault has been safely cleared.

The S201MT-D1.6NA combines a low 1.6 A rating with a Type D characteristic and switched neutral pole. This configuration is particularly useful for suitable auxiliary and control circuits where comparatively high short-duration inrush currents may occur and simultaneous disconnection of phase and neutral is desirable.

Typical Applications

  • Railway and rolling-stock electrical systems.
  • Traction auxiliary and control circuits.
  • Low-current circuits with comparatively high starting or inrush currents.
  • Industrial control and automation equipment.
  • Electrical monitoring and auxiliary systems.
  • Phase-and-neutral circuit protection and isolation.

Technical Specifications

Series S200 MT
ABB order code 2CDS271446R0971
Product type Miniature circuit breaker (MCB)
Pole configuration 1P+N
Rated current 1.6 A
Tripping characteristic Type D
Breaking capacity 10 kA
Protection function Overload and short-circuit protection
Neutral function Switched neutral
Product group DC / Traction MCB
Application Railway / rolling-stock and traction electrical systems
Mounting DIN rail

Frequently Asked Questions

What is the ABB S201MT-D1.6NA used for?

The S201MT-D1.6NA protects electrical circuits against overloads and short-circuits and is particularly suited to railway, rolling-stock, traction and other appropriate low-current applications where high short-duration inrush currents may occur.

What is the rated current of the ABB S201MT-D1.6NA?

The ABB S201MT-D1.6NA has a rated current of 1.6 A.

What does the 1P+N configuration mean?

The 1P+N configuration combines an overcurrent-protected phase pole with a switched neutral pole, allowing the phase and neutral conductors to be disconnected together.

What tripping characteristic does the S201MT-D1.6NA use?

The breaker uses a Type D tripping characteristic, which is suited to appropriate circuits containing equipment with comparatively high short-duration starting or inrush currents.

What is the breaking capacity of the S201MT-D1.6NA?

The ABB S201MT-D1.6NA has a 10 kA breaking capacity for dependable interruption of short-circuit fault currents within its specified operating conditions.

Trusted Circuit Protection from ABB

ABB S200 MT miniature circuit breakers provide dependable overload and short-circuit protection for demanding electrical installations, combining compact DIN-rail construction with configurations developed for railway, rolling-stock and traction applications.