2CDS271339R0487 ABB SU201ML-K20 Miniature Circuit Breaker 14kA 1P K 20A UL489

2CDS271339R0487 ABB SU201ML-K20 Miniature Circuit Breaker 14kA 1P K 20A UL489

ABB SU201ML-K20 is a 20 A single-pole K-characteristic UL 489 miniature circuit breaker with a 14 kA interrupting rating for branch-circuit protection of industrial machinery, control and automation circuits.

SKU: 2CDS271339R0487Alt SKU: SU201MLK20MPN: 2CDS271339R0487
Price
List Price £61.57 ex VAT
Your Price (ex VAT) Save 25%
£46.18 25% OFF
You save £15.39 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £46.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£46.18

Why Choose the ABB SU201ML-K20 Miniature Circuit Breaker?

The ABB SU201ML-K20 is a compact single-pole miniature circuit breaker (MCB) designed for branch-circuit overcurrent and short-circuit protection in industrial electrical, machinery and automation systems. It combines a rated current of 20 A with a K tripping characteristic and UL 489 branch-circuit protection capability.

The SU201ML-K20 uses thermal-magnetic protection to respond to sustained overloads and short-circuit faults. Its K characteristic is particularly suited to inductive loads and equipment with elevated starting currents, helping accommodate normal inrush conditions while maintaining effective protection against damaging overcurrents.

With a 1-pole configuration, 20 A rated current and 14 kA interrupting rating under its UL 489 classification, the SU201ML-K20 provides enhanced short-circuit protection in a compact format. ABB identifies this exact model under order code 2CDS271339R0487, making it suitable for applications where a higher interrupting capacity is required alongside K-characteristic operation.

Key Advantages

  • Compact UL 489 miniature circuit breaker for branch-circuit protection.
  • 20 A rated current for industrial machinery, control and automation circuits.
  • K tripping characteristic suited to inductive loads and equipment with elevated starting currents.
  • 14 kA interrupting rating under its UL 489 classification.
  • Thermal-magnetic operation provides overload and short-circuit protection.
  • Higher interrupting capacity supports applications with greater prospective fault-current requirements.

Key Features

  • ABB SU201ML miniature circuit breaker.
  • 20 A rated current.
  • 1-pole configuration.
  • K tripping characteristic.
  • 14 kA UL 489 interrupting rating.
  • Thermal overload protection.
  • Magnetic short-circuit protection.
  • Designed for UL 489 branch-circuit protection applications.
  • Suitable for industrial machinery, control and automation circuits with inductive loads.
  • Compact modular construction for electrical panel installations.

Reliable Branch-Circuit Protection for Industrial Equipment

Miniature circuit breakers such as the ABB SU201ML-K20 protect electrical circuits and connected equipment against excessive current caused by overload and short-circuit conditions. Thermal-magnetic operation combines delayed thermal overload protection with rapid magnetic response to short-circuit faults, disconnecting the affected circuit when the applicable operating thresholds are exceeded.

The K tripping characteristic is intended for applications where normal operation can involve elevated starting or inrush currents. Combined with its 20 A rating and 14 kA interrupting capability, the SU201ML-K20 is well suited to appropriately rated industrial machinery and automation circuits containing inductive equipment such as motors, transformers, solenoids and similar loads.

Typical Applications

  • Industrial electrical control panels.
  • Machine building and factory automation systems.
  • UL 489 branch-circuit protection.
  • Industrial machinery and auxiliary circuits.
  • Motors and other inductive electrical loads.
  • Transformers, solenoids and automation equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Order code 2CDS271339R0487
Product type Miniature circuit breaker (MCB)
Product group UL489 / UL1077 MCB
Rated current 20 A
Number of poles 1
Tripping characteristic K
Interrupting rating 14 kA
Protection principle Thermal-magnetic
Standard UL 489

Frequently Asked Questions

What is the ABB SU201ML-K20 used for?

The SU201ML-K20 is a UL 489 miniature circuit breaker designed to provide branch-circuit overcurrent and short-circuit protection for industrial electrical panels, machinery and automation equipment.

What is the current rating of the ABB SU201ML-K20?

The SU201ML-K20 has a rated current of 20 A and uses a single-pole configuration.

What does the K characteristic mean on the SU201ML-K20?

The K tripping characteristic is suited to inductive loads and equipment with elevated starting currents, helping accommodate normal inrush conditions while maintaining thermal overload and magnetic short-circuit protection.

What is the interrupting rating of the ABB SU201ML-K20?

The SU201ML-K20 is specified with a 14 kA interrupting rating under its UL 489 classification, providing increased short-circuit interruption capability for appropriately designed installations.

Which standard applies to the ABB SU201ML-K20?

The SU201ML-K20 is specified as a UL 489 miniature circuit breaker for branch-circuit protection and is part of ABB's industrial circuit-protection portfolio.

Trusted ABB Circuit Protection

ABB miniature circuit breakers provide dependable branch-circuit protection for industrial machinery, automation systems and electrical control panels, combining compact construction with reliable thermal-magnetic operation and high short-circuit interruption capability.