2CDS271061R0024 ABB S201M-C2UC 2A Type C 10kA 1P AC/DC Miniature Circuit Breaker

2CDS271061R0024 ABB S201M-C2UC 2A Type C 10kA 1P AC/DC Miniature Circuit Breaker

ABB 2CDS271061R0024 S201M-C2UC single-pole AC/DC miniature circuit breaker with 2 A rated current, Type C tripping characteristic and 10 kA short-circuit breaking capacity.

SKU: 2CDS271061R0024Alt SKU: S201MC2UCMPN: 2CDS271061R0024
Price
List Price £109.60 ex VAT
Your Price (ex VAT) Save 25%
£82.20 25% OFF
You save £27.40 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £82.20
Trade pricing is personalised to your account

Manufacturer Lead Time

£82.20

Why Choose the ABB S201M-C2UC Miniature Circuit Breaker?

The ABB S201M-C2UC (2CDS271061R0024) is a high-performance single-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in AC and DC electrical circuits. Part of ABB’s S200M UC range, this model combines a 2 A rated current, Type C tripping characteristic and 10 kA rated short-circuit breaking capacity.

The S201M-C2UC is specifically designed for applications requiring an MCB suitable for both AC and DC operation. Its UC design incorporates permanent magnets to assist interruption of DC fault currents, making correct polarity and installation in accordance with ABB’s connection requirements important for reliable DC switching performance.

With its compact modular construction and DIN-rail mounting, the S201M-C2UC is suitable for industrial control systems, DC auxiliary circuits, transportation-related electrical systems and other installations requiring dependable low-current circuit protection. ABB’s established S200M platform also provides compatibility with a broad range of system accessories for distribution and control applications.

Key Advantages

  • Provides combined overload and short-circuit protection.
  • 2 A rated current for low-current branch and control circuits.
  • Type C tripping characteristic accommodates moderate inrush currents while maintaining dependable fault protection.
  • 10 kA rated short-circuit breaking capacity provides robust fault interruption capability.
  • UC construction is designed for AC and DC circuit protection.
  • Single-pole configuration provides compact protection for individual circuits.
  • DIN-rail mounting supports straightforward integration into modular electrical assemblies.
  • Part of ABB’s established S200M UC miniature circuit breaker family.

Key Features

  • ABB S201M-C2UC miniature circuit breaker.
  • ABB order code 2CDS271061R0024.
  • 1-pole configuration.
  • 2 A rated current (In).
  • C-curve instantaneous tripping characteristic.
  • 10 kA breaking capacity.
  • Designed for AC/DC applications.
  • Thermal-magnetic protection against overloads and short circuits.
  • UC design optimised for reliable interruption of DC currents.
  • Compact modular construction.
  • Designed for DIN-rail mounting.

Reliable Protection for AC and DC Circuits

Miniature circuit breakers protect wiring and connected equipment by automatically disconnecting a circuit when excessive current occurs. The thermal element responds to sustained overload conditions, while the magnetic mechanism provides rapid operation under high short-circuit currents. The Type C characteristic is suited to circuits where moderate starting or inrush currents may occur during normal operation.

DC fault interruption places different demands on a circuit breaker because direct current has no natural current zero crossing. The ABB S200M UC range is engineered for these applications using permanent magnets to assist arc extinction. For this reason, the specified polarity and connection arrangement must be observed in DC installations to ensure the breaker operates as designed.

Typical Applications

  • DC distribution and auxiliary circuits.
  • Traction and transportation electrical systems.
  • Industrial control panels and switchboards.
  • Automation and instrumentation circuits.
  • Low-current power distribution circuits.
  • AC/DC control and auxiliary power systems.

Technical Specifications

Series S200M UC
Order code 2CDS271061R0024
Product type Miniature circuit breaker (MCB)
Product group DC / Traction MCB
Number of poles 1
Rated current (In) 2 A
Tripping characteristic Type C
Rated short-circuit breaking capacity 10 kA
Protection principle Thermal-magnetic
Current type AC/DC
Mounting DIN rail
Standards IEC/EN 60898-1 and IEC/EN 60947-2

Frequently Asked Questions

What is the rated current of the ABB S201M-C2UC?

The ABB S201M-C2UC has a rated current of 2 A and is a single-pole miniature circuit breaker.

What tripping characteristic does the ABB S201M-C2UC use?

The S201M-C2UC has a Type C tripping characteristic, providing overload and short-circuit protection while accommodating moderate normal inrush currents.

What is the breaking capacity of the ABB 2CDS271061R0024?

The S201M-C2UC has a rated short-circuit breaking capacity of 10 kA.

Can the ABB S201M-C2UC be used on DC circuits?

Yes. The S200M UC family is designed for AC and DC applications. For DC use, ABB’s specified polarity and connection arrangement must be followed because the breaker uses permanent magnets to assist DC arc interruption.

What protection does the ABB S201M-C2UC provide?

The S201M-C2UC uses thermal-magnetic protection, providing protection against sustained overload currents and short-circuit faults.

Trusted Circuit Protection from ABB

ABB S200M UC miniature circuit breakers provide compact thermal-magnetic protection for demanding AC and DC applications, with the S201M-C2UC combining a 2 A rating, Type C characteristic and 10 kA short-circuit breaking capacity in a single-pole DIN-rail device.